HomeMy WebLinkAboutA1.0 ExistingEXISTING FIRE WALL
SUPPORT COLUMN
WOOD ROOF TRUSSES
24" O.C. (TYP)
SUPPORT BEAM
ELECTRICAL PANEL
REMOVE BLOCK WALL
UNIT 120
NOT IN CONSTRUCTION
2,487 SF
NON-SPRINKLERED
UNFINISHED AREA
2,387 SF
NON-SPRINKLERED
UTILITIES
OFFICE
OFFICE
UNIT 116 UNIT 118
+11'-11 3/8"
RAFTERS60'-9 1/2"39'-5 1/2"
ELECTRICAL PANEL
OFFICE
OFFICE
STORAGE
LOBBY
OPEN OFFICE
MLHPLOT SCALE:DATE:CHECKED BY:DRAWN BY:SHEET NO.
JOB NO.
SCOPE DOCUMENT
THE DRAWINGS INDICATE THE GENERAL
SCOPE OF THE PROJECT IN TERMS OF
ARCHITECTURAL DESIGN CONCEPT, THE
DIMENSIONS OF THE BUILDING, THE
MAJOR ARCHITECTURAL ELEMENTS AND
THE TYPE OF STRUCTURAL,
MECHANICAL AND ELECTRICAL
SYSTEMS. AS SCOPE DOCUMENTS, THE
DRAWINGS DO NOT NECESSARILY
INDICATE OR DESCRIBE ALL WORK THAT
IS REQUIRED FOR FULL PERFORMANCE
AND COMPLETION OF THE
REQUIREMENTS OF THE CONTRACT
DOCUMENTS. ON THE BASIS OF THE
GENERAL SCOPE INDICATED OR
DESCRIBED, THE TRADE CONTRACTORS
SHALL FURNISH ALL ITEMS REQUIRED
FOR THE PROPER EXECUTION AND
COMPLETION OF THE WORK.AS NOTED09.11.2020THE SEAL(S) AND SIGNATURE(S) APPLY
ONLY TO THE DOCUMENT TO WHICH
THEY ARE AFFIXED AND WE EXPRESSLY
DISCLAIM ANY RESPONSIBILITY FOR ALL
OTHER PLANS, SPECIFICATIONS,
ESTIMATES, REPORTS, OR OTHER
DOCUMENTS OR INSTRUMENTS
RELATING TO OR INTENDED TO BE USED
FOR ANY PART OR PARTS OF THE
PROJECT.
COPYRIGHT 2020 HOLDER DESIGN, INC.
REVISIONS
A20-020 SHEET DESCRIPTION: -24 South 5th Street
Terre Haute, Indiana
47807
ph. 812.235.1300
www.holderdesign.net
HOLDERDESIGN, INC.Premier Family ChiropracticTENANT EXPANSIONCARMEL, INDIANA INSTRUCTIONS FOR:EXISTING CONDITIONSAMA1.0
KEYED PLAN NOTES:
DEMO PORTION OF EXISTING BLOCK WALL COMPLETE
DEMO EXISTING STUD WALL COMPLETE
REMOVE AND SALVAGE EXISTING INTERIOR POCKET DOOR
1
KEY:
DEMO
EXISTING PARTITIONS TO REMAIN
NEW STUD PARTITIONS
2
3
3
1
2
2
2
GENERAL DEMOLITION NOTES
REMOVE ALL EXISTING CONSTRUCTIONS AND FINISHES NECESSARY FOR THE COMPLETION OF THE WORK AS
DEPICTED ON THE DRAWINGS. INCLUDING BUT NOT LIMITED TO ITEMS SHOWN ON THE PLANS WITH DASHED
LINES. NECESSARY DISCONNECTS AND ALTERATIONS TO EXISTING MECHANICAL AND ELECTRICAL SYSTEMS
SHALL BE INCLUDED. PATCH AS REQUIRED ALL CONSTRICTIONS TO REMAIN IN ACCORDANCE WITH THE
CONTRACT DRAWINGS.WHERE CONTRACTOR IS DESIGNATED TO MAKE REMOVALS, DISPOSITION OF MATERIALS
IS THE RESPONSIBILITY OF THE CONTRACTOR. VERIFY WITH THE OWNER, THE DISPOSITION AND REMOVAL OF
ANY COMPONENTS OF SALVAGEABLE VALUE.
ALL REMOVALS AND SALVAGE, UNLESS SPECIFICALLY NOTED OR REQUESTED BY THE OWNER SHALL BECOME
THE PROPERTY OF THE CONTRACTOR.
REMOVE ONLY NON-LOAD BEARING CONSTRUCTION AND PARTITIONS. CONTRACTOR TO VERIFY, PRIOR TO
REMOVAL THAT NO STRUCTURAL COMPONENTS, I.E. BEARING WALLS, BEAMS, HEADERS, ETC.. SUPPORTING
FLOOR, ROOF, OR CEILING JOISTS ARE DESIGNATED FOR REMOVAL. CONTACT THE ARCHITECT PRIOR TO
REMOVAL OF ANY CONSTRUCTION IN QUESTION OR DEVIATING FROM THE DESIGN INTENT. CONTRACTORS
NON-CONTACT OF ARCHITECT PRIOR TO REMOVAL OF ANY WORK INDICATES HIS COMPLETE UNDERSTANDING
THAT NO LOAD BEARING OR STRUCTURAL WORK IS BEING ALTERED UNDER THIS CONTRACT.
PATCH ALL FINISHES TO MATCH EXISTING, INCLUDING BUT NOT LIMITED TO, GYPSUM BOARD, PLASTER,
ACOUSTIC SYSTEMS, WOODTRIM, COVERS, BASE, PANELS, RAILS, AND WAINSCOT. VERIFY MATCH OF NEW FINISH
MATERIALS TO EXISTING IN COLOR, TEXTURE, THICKNESS, CUT, ETC.. TO SATISFACTION OF OWNER PRIOR TO
INSTALLATIONS. PROVIDE OTHER MATERIALS TO MATCH EXISTING WHEN REQUIRED. TO BE APPROVED BY
OWNER.
PATCH EXISTING WALLS GYPSUM DRYWALL OR PLASTER TO MATCH EXISTING OF SUFFICIENT THICKNESS TO
MAINTAIN UNIFORM WALL THICKNESS. ALL EXPOSED PORTIONS OF WALL SHALL BE FINISHED WITH THREE (3)
COATS OF SPECKLING, SANDED AND LEFT IN A PAINT READY CONDITION.
WHERE APPLICABLE LEVEL ALL EXISTING FLOORS AS REQUIRED TO RECEIVE NEW FLOOR FINISHES. INSTALL
REQUIRED TRANSITION PIECES BETWEEN VARIOUS FLOOR FINISHED SUITABLE FOR CONDITIONS AND
ACCEPTABLE TO THE OWNER. MATCH EXISTING WHEREVER POSSIBLE.
CONTRACTOR SHALL INSURE ALL WORK IS IN CONFORMANCE WITH ALL APPLICABLE BUILDING CODES. WORK
SHALL BE COMPLETED IN STRICT ACCORDANCE WITH THE LATEST EDITIONS BUILDING CODE AND ENERGY
CONSERVATION CODE, PLUMBING CODE, NATIONAL ELECTRICAL CODE, AND ALL OTHER FEDERAL, STATE AND
LOCAL AGENCY REGULATIONS HAVING JURISDICTION OVER THIS PROJECT. IN THE EVENT OF ANY
DISCREPANCIES BETWEEN AGENCY REQUIREMENT. THE CONTRACTOR SHALL OBSERVE THE MORE STRINGENT
OF REQUIREMENTS.
ALL WORK SHALL COMPLY WITH THE STANDARDS OF THE NATIONAL BOARD OF FIRE UNDERWRITERS (NBFU0,
INDUSTRIAL RISK INSURANCE UNERWRITERS (IRI), FACTORY MUTUAL (FW), OR THE APPLICABLE RATING BUREAU.
THE NATIONAL ELECTRIC CODE (NEC), THE AMERICAN GAS ASSOCIATION (AGA), AND THE AMERICAN SOCIETY OF
HEATING AND AIR CONDITIONING ENGINEERS (ASHAE), OCCUAPTIONAL SAFETY AND HEALTH ADMINISTRATION
(OSHA), APPLICABLE STATE AND CITY BUILDING CODES AND THE REQUIREMENTS OF ALL PUBLIC UTILITY
COMPANIES SERVING THE PROJECT SITE.
CONTRACTOR (AND HIS SUBCONTRACTORS) SHALL BE LICENSED BY THE STATE IN WHICH THE PROJECT IS
LOCATED AND APPROVED IN ADVANCE BY THE OWNER.
ALL WORK IS TO BE COORDINATED WITH THE OWNER. THE CONTRACTOR IS TO MEET WITH THE OWNER PRIOR TO
STARTING CONSTRUCTION.
CHECK WITH THE OWNER FOR COORDINATION OF THE WORK UNDER THIS CONTRACT WITH WORK OF OTHER
TRADES. OWNER'S REGULATIONS GOVERN ALL ASPECTS OF OUTSIDE CONTRACTORS WORKING ON THE
PROPERTY.
CONTRACTOR SHALL KEEP THE JOB FREE OF DEBRIS AND MAKE FINAL CLEANUP TO THE SATISFACTION OF THE
OWNER. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL OF ALL CONSTRUCTION DEBRIS FROM PROJECT
SITE AND SHALL PROVIDE DUMPSTER'S ETC. AS REQUIRED. REMOVE ALL DEBRIS ON A DAILY BASIS.
CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL EXISTING BUILDINGS AND OTHER
INSTALLATIONS THAT ARE TO REMAIN INTACT WHILE PERFORMING THE SPECIFIED WORK. PROVIDE AND
MAINTAIN FIRE EXTINGUISHERS ON PROJECT SITE DURING CONSTRUCTION.
UNLESS INDICATED OTHERWISE, ALL MATERIAL FURNISHED AND INCORPORATED INTO THE WORK SHALL BE NEW,
UNUSED, AND OF QUALITY STANDARD TO THE INDUSTRY FOR FIRST CLASS WORK OF SIMILAR NATURE AND
CHARACTER. INSTALL ALL MATERIALS TO THE MANUFACTURER'S RECOMMENDATIONS AND BEST STANDARD OF
THE TRADES INVOLVED.
CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS IN FIELD PRIOR CONSTRUCTION. NOTIFY ARCHITECT IS ANY
DISCREPANCIES ON DRAWINGS.
PROVIDE SLEEVE THROUGH FOUNDATION FOR PENETRATIONS AS REQUIRED. COORDINATE W/ CIVIL
ENGINEERING DOCUMENTS.
CONTRACTOR SHALL PROVIDE ANY NECESSARY MEASURE TO PROTECT THE WORKERS AND OTHER PERSONS
DURING CONSTRUCTION.
CONTRACTOR & MEP CONTRACTOR SHALL VERIFY LOCATION OF ROOF MOUNTED EQUIPMENT.
INTERIOR FINISHES SHALL BE CLASS C (SURFACE FLAME SPREAD RATING OF 76-200)MINIMUM IN CONFORMITY
WITH GENERALLY ACCEPTED STANDARDS. CARPETING SHALL BE CLASS 2 WITH A MINIMUM CRITICAL RADIANT
FLUX OF 22-WATTS PER SQUARE CENTIMETER.
ALL GYPSUM BOARD WORK SHALL BE DONE IN ACCORDANCE WITH THE DRYWALL CONSTRUCTION HANDBOOK,
LATEST EDITION. PREPARED BY UNITED STATES GYPSUM. ALL JOINTS AND SEAMS SHALL BE TAPED AND
FINISHED IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION RECOMMENDATIONS.
VISIT THE SITE TO VERIFY EXISTING CONDITIONS. EXISTING CONCEALED CONDITIONS AND CONNECTIONS ARE
BASED UPON INFORMATION TAKEN FROM LIMITED FIELD INVESTIGATIONS. CONTRACTOR SHALL MAKE REQUIRED
ADJUSTMENTS TO SYSTEM COMPONENTS AS NECESSITATED BY ACTUAL FIELD CONDITIONS AT NO ADDITIONAL
COST TO OWNER OR ARCHITECT. REPORT ANY DISCREPANCIES BETWEEN THE DRAWINGS AND ACTUAL FIELD
CONDITIONS TO THE ARCHITECT BEFORE CONSTRUCTION.
A1.0 SCALE: 1/4" = 1'-0"
1 EXISTING CONDITIONS
N
10/23/20