Loading...
HomeMy WebLinkAboutA0.1 Life Safety PlanNO 2nd FLOOR IN THIS AREA OPEN TO WAREHOUSE (BELOW) EXIST. OFFICE EXIST. BATH EXIST. RR EXIST. BREAK 1,001 SQ. FT. EXIST. OFFICE EXIST. OFFICE EXIST. OFFICE STGE279 SQ. FT. EXISTING OPEN SPACE 1,247 SQ. FT. EXISTING CONFERENCE ROOM EXIT (1st FL) TRAVEL DISTANCE = 84' FP EXISTING WAREHOUSE OPEN TO ABOVE 6,686 SQ. FT. EXISTING OFFICE SPACE 1,167 SQ. FT. EXISTING WOMEN'S EXISTING MEN'S EXIST. BREAK EXITTRAVEL DISTANCE = 54'EXITTRAVEL DISTANCE = 78' EXITTRAVEL DISTANCE = 81'EXITTRAVEL DISTANCE = 81'EXIT TRAVEL DISTANCE = 96'TRAVEL DISTANCE = 105' NORTH 3/32" = 1'-0" 1st Floor Life Safety Plan Life Safety PlansA0.1TMKTSQUANTUMARCHITECTUREPO Box 56032 Indianapolis, IN 46256317-413-9497 www.q-architecture.comCKH Realty, LLC9800 Association CourtIndianapolis, IN 462804/20/202019018FE LEGEND LOCATION OF FIRE EXTINGUISHER EXIT SIGN EXIT SIGN / EMERGENCY LIGHT COMBO EMERGENCY LIGHT LOCATION OF EXIT DISTANCE OF TRAVEL TO EXIT AREA NOT IN CONTRACT 2-HOUR SEPARATION WALL. SEE FLOOR PLAN FOR MORE INFORMATION. EXIT TRAVEL DISTANCE = X NORTH 3/32" = 1'-0" 2nd Floor Life Safety Plan CALCULATED OCCUPANCY Classroom 1,492 @20 SF/P OCCUPANCY CALCULATION 75 Unconcetrated 1,798 @15 SF/P PROJECTED OCCUPANCY (for Restroom Count) Toilet Count Calculation Max. Total Projected Occupants 167 Needed Toilets (1 per 75 People) 2 Women 84 Needed Lavatories (1 per 200 People) 1 Needed Toilets (1 per 150 People) 1 Men 84 Needed Lavatories (1 per 200 People) 1 Drinking Fountain Existing to remain ASSEMBLY (A-3) 6,305 @100 SF/P 64 BUSINESS (B) 6,686 @200 SF/P 34 STORAGE (S-2) 120 294TOTAL Storage 92 @300 SF/P 1 196Subtotal Maximum Employees/Shift 3 Maximum Public ASSEMBLY (A-3) 164 167Subtotal Maximum Employees/Shift 6 Maximum Public Business (B) 50 56Subtotal Maximum Employees/Shift 2 Maximum Public Storage (S-2) 30 32Subtotal 1 ASSEMBLY (A-3) Max. Total Projected Occupants 56 Needed Toilets (1 per 25 People) 2 Women 28 Needed Lavatories (1 per 40 People) 1 Needed Toilets (1 per 25 People) 2 Men 28 Needed Lavatories (1 per 40 People) 1 Business (B) Max. Total Projected Occupants 32 Needed Toilets (1 per 100 People) 1 Women 16 Needed Lavatories (1 per 100 People) 1 Needed Toilets (1 per 100 People) 1 Men 16 Needed Lavatories (1 per 100 People) 1 Storage (S-2) Toilets Women Lavatories Toilets Men Lavatories TOTAL NEEDED Toilets Women Lavatories Toilets (2 are Urinals) Men Lavatories TOTAL AVAILABLE Toilets Unisex Lavatories Toilets Total Lavatories Toilets 12 Total Lavatories 8 1 5 3 4 3 4 2 4 2 4 4 9 6 9 6 Needed Avail. +3 +2 Net Maximum Employees/Shift 11 Maximum Public TOTAL 244 255TOTAL 1 1 1 1 10/29/20