HomeMy WebLinkAboutA2.1 First Floor PlanFP EXISTING WAREHOUSE OPEN TO ABOVE 6,686 SQ. FT. 92 SEATS (115 MAX) ALTERNATE #1 1 A5.16'-034"19'-718"5 1 1 2 3 4 7'-918"1'-358"45°4 6 7 S3SS3S2 A5.1 SS 5'-0" 3'-8"10 T @ 11" = 9'-2"13"3'-8" BUILT-UP 2x POSTS FOR STAIR LANDING SUPPORT (TYPICAL) 104 MINISTRY 1 105 MINISTRY 2 101 VESTIBULE 102 ENTRY EXISTING OFFICE SPACE 1,167 SQ. FT. 103 COMMON AREA 108 PRE-FUNCTION 107 COFFEE 106 WOMEN 110 MEN 109 MECH. 111 MINISTRY 3 112 MINISTRY4 113 WORSHIP + 18 SEATS 114 OVERFLOW 115 STORE ROOM 117 VESTIBULE 116 HALL 117A116B117B115 116A 108B 108A113108C108A HALL 1051049 10 11 11 11 11 11 11 EXISTING WOMEN'S EXISTING MEN'S EXIST. BREAK 4'-8"± CPT2 EXISTING CONCRETE FLOOR CPT2 CPT1 CPT1 118 STAIR CPT2 1 2 EXISTING SLATE TO REMAIN QUANTUMARCHITECTUREPO Box 56032 Indianapolis, IN 46256317-413-9497 www.q-architecture.comCKH Realty, LLC9800 Association CourtIndianapolis, IN 462804/20/2020190181st Floor PlanA2.1TMKTSNORTH1/8" = 1'-0" 1st Floor Plan WALL TYPE SCHEDULE EXISTING WALL TO REMAIN - PATCH AND/OR REPAIR AS REQUIRED TO MATCH EXISTING ADJACENT CONSTRUCTION AND FINISHES. TYPICAL NEW WALL - 358" OR 6" 25 GA. METAL STUDS @ 16" O.C. w/ 58" TYPE 'X' GYPSUM BOARD ON BOTH SIDES. - WHERE CEILING IS OPEN TO DECK, EXTEND WALL TO DECK ABOVE. - WHERE CEILING GRID IS CONTINUOUS FROM ROOM TO ROOM, EXTEND WALL TO UNDERSIDE OF GRID. - WHERE CEILING GRIDS ARE NOT CONTINUOUS FROM ROOM TO ROOM, EXTEND STUDS AND GYPSUM BOARD TO MINIMUM OF 4" ABOVE GRID. 2-HOUR SEPARATION WALL. SEE PLAN NOTE #1. AREA NOT IN CONTRACT NEW 2-HOUR SEPARATION WALL TO ROOF ABOVE. 6" 20 GA METAL STUDS @ 16" O.C. w/ (2) LAYERS 58" TYPE 'X' GYPSUM BOARD ON EACH SIDE. FIRE SILL AT METAL ROOF. MODIFY BATT INSULATION AT ROOF AS REQUIRED. ALL WALL OPENINGS SHALL HAVE A 90 MINUTE FIRE RATING. INFILL EXISTING WALL OPENING WITH NEW CONSTRUCTION TO MATCH EXISTING ADJACENT CONSTRUCTION. PROVIDE SMOOTH EVEN TRANSITION FROM OLD SURFACE TO NEW. NEW WALL TO BE CENTERED ON EXISTING WINDOW MULLION. ALIGN NEW WALL WITH EDGE OF EXISTING WALL. PROVIDE SMOOTH EVEN TRANSITION FROM OLD SURFACE TO NEW. NEW 2-HOUR SEPARATION WALL TO ROOF ABOVE. 6" 20 GA METAL STUDS @ 16" O.C. w/ (4) LAYERS 58" TYPE 'X' GYPSUM BOARD ON ONE SIDE PER GA FILE NO. WP 7125. FIRE SILL AT METAL ROOF. MODIFY BATT INSULATION AT ROOF AS REQUIRED. ALL WALL OPENINGS SHALL HAVE A 90 MINUTE FIRE RATING. EXTEND NEW WALL TO UNDERSIDE OF CEILING AT CLERESTORY ABOVE. TOP OF VESTIBULE WALLS AT 12"ABOVE EXISTING WINDOW HEAD. NOT USED. EXISTING ALUMINUM STOREFRONT SYSTEM TO BE REWORKED FROM SINGLE ENTRY DOOR TO TWO SEPARATE ENTRY DOORS. RELOCATE EXISTING EMERGENCY LIGHT TO BE IN WAREHOUSE. NEW EMERGENCY/EXIT LIGHT LOCATION. SEE LIFE SAFETY PLAN FOR MORE INFORMATION. NOT USED. GENERAL NOTES A. TYPICAL DIMENSIONS ON THIS PLAN ARE FROM FACE OF FINISHED WALL TO FACE OF FINISHED WALL. B. PATCH AND REPAIR ALL AREAS AFFECTED BY DEMOLITION AND NEW WORK TO MATCH EXISTING ADJACENT CONSTRUCTION. C. SEE SHEET A7.1 FOR DOOR SCHEDULE. D. DOORS ON THIS PLAN WHICH DO NOT HAVE A DOOR NUMBER ARE EXISTING TO REMAIN. E. EXISTING LIGHT FIXTURES AND SWITCHES TO REMAIN UNLESS NOTED OTHERWISE. PLAN NOTES 1 2 3 4 5 7 8 9 10 11 6 12 1 1 1 10/29/20