HomeMy WebLinkAboutA2.1 First Floor PlanFP
EXISTING
WAREHOUSE
OPEN TO ABOVE
6,686 SQ. FT.
92 SEATS
(115 MAX)
ALTERNATE #1
1
A5.16'-034"19'-718"5
1
1
2
3
4 7'-918"1'-358"45°4
6
7
S3SS3S2
A5.1
SS 5'-0" 3'-8"10 T @ 11" = 9'-2"13"3'-8"
BUILT-UP 2x POSTS FOR
STAIR LANDING SUPPORT
(TYPICAL)
104
MINISTRY 1
105
MINISTRY 2
101
VESTIBULE
102
ENTRY
EXISTING
OFFICE SPACE
1,167 SQ. FT.
103
COMMON AREA
108
PRE-FUNCTION
107
COFFEE
106
WOMEN
110
MEN
109
MECH.
111
MINISTRY 3
112
MINISTRY4
113
WORSHIP
+ 18 SEATS
114
OVERFLOW
115
STORE
ROOM
117
VESTIBULE
116
HALL
117A116B117B115
116A
108B
108A113108C108A
HALL
1051049
10
11
11
11
11
11
11
EXISTING
WOMEN'S
EXISTING
MEN'S
EXIST.
BREAK
4'-8"±
CPT2
EXISTING
CONCRETE
FLOOR CPT2
CPT1
CPT1
118
STAIR
CPT2
1
2
EXISTING
SLATE TO
REMAIN
QUANTUMARCHITECTUREPO Box 56032 Indianapolis, IN 46256317-413-9497 www.q-architecture.comCKH Realty, LLC9800 Association CourtIndianapolis, IN 462804/20/2020190181st Floor PlanA2.1TMKTSNORTH1/8" = 1'-0"
1st Floor Plan
WALL TYPE SCHEDULE
EXISTING WALL TO REMAIN - PATCH AND/OR REPAIR AS REQUIRED TO MATCH EXISTING
ADJACENT CONSTRUCTION AND FINISHES.
TYPICAL NEW WALL - 358" OR 6" 25 GA. METAL STUDS @ 16" O.C. w/ 58" TYPE 'X'
GYPSUM BOARD ON BOTH SIDES.
- WHERE CEILING IS OPEN TO DECK, EXTEND WALL TO DECK ABOVE.
- WHERE CEILING GRID IS CONTINUOUS FROM ROOM TO ROOM, EXTEND WALL TO
UNDERSIDE OF GRID.
- WHERE CEILING GRIDS ARE NOT CONTINUOUS FROM ROOM TO ROOM, EXTEND
STUDS AND GYPSUM BOARD TO MINIMUM OF 4" ABOVE GRID.
2-HOUR SEPARATION WALL. SEE PLAN NOTE #1.
AREA NOT IN
CONTRACT
NEW 2-HOUR SEPARATION WALL TO ROOF ABOVE. 6" 20 GA METAL
STUDS @ 16" O.C. w/ (2) LAYERS 58" TYPE 'X' GYPSUM BOARD ON EACH
SIDE. FIRE SILL AT METAL ROOF. MODIFY BATT INSULATION AT ROOF
AS REQUIRED. ALL WALL OPENINGS SHALL HAVE A 90 MINUTE FIRE
RATING.
INFILL EXISTING WALL OPENING WITH NEW CONSTRUCTION TO MATCH
EXISTING ADJACENT CONSTRUCTION. PROVIDE SMOOTH EVEN
TRANSITION FROM OLD SURFACE TO NEW.
NEW WALL TO BE CENTERED ON EXISTING WINDOW MULLION.
ALIGN NEW WALL WITH EDGE OF EXISTING WALL. PROVIDE SMOOTH
EVEN TRANSITION FROM OLD SURFACE TO NEW.
NEW 2-HOUR SEPARATION WALL TO ROOF ABOVE. 6" 20 GA METAL
STUDS @ 16" O.C. w/ (4) LAYERS 58" TYPE 'X' GYPSUM BOARD ON ONE
SIDE PER GA FILE NO. WP 7125. FIRE SILL AT METAL ROOF. MODIFY
BATT INSULATION AT ROOF AS REQUIRED. ALL WALL OPENINGS SHALL
HAVE A 90 MINUTE FIRE RATING.
EXTEND NEW WALL TO UNDERSIDE OF CEILING AT CLERESTORY ABOVE.
TOP OF VESTIBULE WALLS AT 12"ABOVE EXISTING WINDOW HEAD.
NOT USED.
EXISTING ALUMINUM STOREFRONT SYSTEM TO BE REWORKED FROM
SINGLE ENTRY DOOR TO TWO SEPARATE ENTRY DOORS.
RELOCATE EXISTING EMERGENCY LIGHT TO BE IN WAREHOUSE.
NEW EMERGENCY/EXIT LIGHT LOCATION. SEE LIFE SAFETY PLAN FOR
MORE INFORMATION.
NOT USED.
GENERAL NOTES
A. TYPICAL DIMENSIONS ON THIS PLAN ARE FROM FACE OF FINISHED WALL
TO FACE OF FINISHED WALL.
B. PATCH AND REPAIR ALL AREAS AFFECTED BY DEMOLITION AND NEW
WORK TO MATCH EXISTING ADJACENT CONSTRUCTION.
C. SEE SHEET A7.1 FOR DOOR SCHEDULE.
D. DOORS ON THIS PLAN WHICH DO NOT HAVE A DOOR NUMBER ARE
EXISTING TO REMAIN.
E. EXISTING LIGHT FIXTURES AND SWITCHES TO REMAIN UNLESS NOTED
OTHERWISE.
PLAN NOTES
1
2
3
4
5
7
8
9
10
11
6
12
1
1 1
10/29/20