Loading...
HomeMy WebLinkAbout9800 Association Court Ch 34 Analysis Garage Revised9800 Association Court S-2 Occupancy Indianapolis, IN Chapter 34 Analysis 1. The project involves the conversion of a portion of the 1 st floor of an existing building into a church and the existing warehouse will be used to store vehicles. The remainder of the building will remain as offices. The church and office space will be separated from the warehouse/garage by a 2-hour fire barrier. The building will be classified as an A-3/B/S-2 Occupancy. The existing building is 2-stories and Type IIIB Construction. The 1st floor is 13,846 sq.ft. and the 2nd floor is 2,527 sq.ft. 2. The proposed conversion of the building is classified as a “change of occupancy” per Rule 4, Section 11(b), GAR. 3. Rule 4, Section 11(b), GAR, permits existing structures undergoing a change in occupancy to comply with either; • The rules for new construction for the proposed new use, or • Sec. 3412, IBC, “Compliance Alternatives” 4. Due to issues involved with bringing the existing building into compliance with all current rules of the Commission, Sec. 3412, IBC is used as the benchmark method of evaluating existing building compliance for the proposed use of the building. 5. The proposed strategy will permit the conversion of the building for the proposed use based upon conditions of the building as indicated in the attached score sheets. • The church and office space will be separated from the warehouse/garage by a 2-hour fire barrier, with 90-minute rated openings. • A smoke detection system is provided in the HVAC where required by the IMC. • Exit signs and emergency lighting will be provided in the garage. 9800 Association Court S-2 Occupancy Indianapolis, IN Building Score Sheet Table 3412.7 Section Safety Parameter Fire Safety (FS) Means of Egress (ME) General Safety (GS) 3412.6.1 Building Height 2.4 2.4 2.4 3412.6.2 Building Area 11.5 11.5 11.5 3412.6.3 Compartmentation 10.7 10.7 10.7 3412.6.4 Tenant and Dwelling Unit Separations 4.0 4.0 4.0 3412.6.5 Corridor Walls 0.0 0.0 0.0 3412.6.6 Vertical Openings 2.0 2.0 2.0 3412.6.7 HVAC Systems 5.0 5.0 5.0 3412.6.8 Automatic Fire Detection 0.0 0.0 0.0 3412.6.9 Fire Alarm System -10.0 -10.0 -10.0 3412.6.10 Smoke Control 0.0 0.0 3412.6.11 Means of Egress 0.0 0.0 3412.6.12 Dead Ends 2.0 2.0 3412.6.13 Maximum Exit Access Travel Distance 11.1 11.1 3412.6.14 Elevator Control 0.0 0.0 0.0 3412.6.15 Means of Egress Emergency Lighting 4.0 4.0 3412.6.16 Mixed Occupancies 0.0 0.0 3412.6.17 Automatic Sprinklers 0.0 0.0 0.0 3412.6.18 Standpipes 0.0 0.0 0.0 3412.6.19 Incidental Use 0.0 0.0 0.0 Total Building Score 25.6 42.7 42.7 Required Building Score 23.0 33.0 33.0 Pass (+)/ Fail(-) 2.6 9.7 9.7 9800 Association Court S-2 Occupancy Indianapolis, IN SUMMARY SHEET - BUILDING SCORE Existing occupancy B/S-1 Proposed occupancy A-3/B/S-2 Year building was constructed early 1980's & 2000's Number of stories 2 Ht. 25' Type of construction Type IIIB Area per floor 1 st: 13,846 sf 2nd: 2,527 sf Percentage of open perimeter 100 % Percentage of height reduction N/A Completely suppressed Yes No X Corridor wall rating N/A Compartmentation Yes X No Required door closers Yes No Fire resistance rating on vertical opening enclosures Garage is 1-story Type of HVAC System forced air ,serving number of floors 1 Automatic fire detection Yes X No Type and location In HVAC per IMC Fire alarm system Yes No X Type Smoke control Yes No X Type Adequate exit routes Yes X No Dead ends: Yes No X Maximum exit access travel distance 89 feet Elevator controls: Yes No X Means of egress emergency lighting Yes X No Mixed occupancies: Yes X No EVALUATION FORMULA Formula Building Score Sheet Table 3412.8 Pass/Fail FS - MFS > 0 25.6 (FS) - 23 (MFS) = +2.6 ME - MME > 0 42.7 (ME) - 33 (MME) = +9.7 GS - MGS > 0 42.7 (GS) - 33 (MGS) = +9.7 9800 Association Court S-2 Occupancy Indianapolis, IN Building Score Sheet Analysis 3412.6.1 The S-2 fire area is 1-story in height. The building is permitted to be 4 stories and 55' in height based upon an S-2 Occupancy of Type IIIB Construction. Height Value for feet: (55 - 25)/12.5 = 2.4 Height Value for number of stories: 4 - 1 = 3 (lessor value for stories is used in the score sheet) 3412.6.2 Allowable area for Type IIIB Construction for separated mixed uses of an A-3/B & S-2 Occupancy: Allowable area: A-3/B = Tabular (9,500 sf) + Frontage (7,125 sf) = 16,625 sf Allowable area: S-2 = Tabular (26,000 sf) + Frontage (19,500 sf) = 45,500 sf Value = 45,500/1,200 [1- (6,677/16,625 + 7,169/45,500)] = 16.7* *Maximum score is 50% the fire safety mandatory score = 11.5 3412.6.3 The fire area is 7,169 square feet. Compartmentation value = 10 + (7,169 - 7,500)[(15-10)/(5,000-7,500)] = 10.7 3412.6.4 The S-2 Occupancy is separated from the rest of the building by a 2-hour fire barrier. Value = 4 3412.6.5 The S-2 Occupancy does not have corridors. Value = 0 3412.6.6 The S-2 Occupancy is 1-story. Value = 2 3412.6.7 The S-2 Occupancy is served by a separate HVAC system. Value = 5 3412.6.8 The HVAC has smoke detection per the IMC. Value = 0 3412.6.9 A manual fire alarm system will not be provided in the S-2 Occupancy. Value = 0 3412.6.10 The building has no smoke control. Value = 0 3412.6.11 The required number of exits and exit width are provided in accordance with sections 1004 and 1021. Value = 0 3412.6.12 There are no dead end corridors. Value = 2 3412.6.13 The maximum exit access travel distance is 89 feet, 200 feet is permitted. Points = 20 x ((200-89)/200) = 11.1 3412.6.14 An elevator is not required. Value = 0 3412.6.15 Means of egress lighting and exit signs with emergency power provided in accordance with section 1006.3 where more than one exit is required by Section 1015. Illumination is provided in the event of power failure. Value = 4 3412.6.16 Building is evaluated for non-separated & separated mixed uses. Value = 0 3412.6.17 Sprinklers are not required based upon the fire area not exceeding 12,000 sf. Fire Safety Value = 0, Means of Egress Value = 0, General Safety Value = 0 3412.6.18 Standpipes are not required and are not provided. Value = 0 3412.6.19 None applicable to this project. Value = 0 RTM CONSULTANTS, INC. — 6640 PARKDALE PLACE, SUITE J. — INDIANAPOLIS, IN 46254-4698 tel: 317-329-7700 — fax: 317-329-8411 — www.rtmconsultants.com