Loading...
HomeMy WebLinkAboutAE1-300-ROOF-PLAN2 AE3-004 2,985 SQ FT ATTIC SPACE E 2,941 SQ FT ATTIC SPACE D 2,665 SQ FT ATTIC SPACE C 2,457 SQ FT ATTIC SPACE B 2,772 SQ FT ATTIC SPACE A2' - 0"6 : 12 RIDGEVALLEY VALLEYHIPHIPVALLEYRIDGERIDGE RIDGEVALL E Y V A L L E Y RIDGERIDGE10:1210:12VALLEYVALLEYRIDGE6:12 6:12 VALLEYVALLEYRIDGE6:12 6:12 6 : 12 RIDGE VALLEYVALLEY6:12 6:12RIDGE V A LLE Y V A L L E Y HIPHIP4 : 124 : 12 4 : 126 : 126 : 126 : 126 : 124 : 124 : 12 4 1/2 : 12 4 1/2 : 12 6 : 12 VALLEYHIPRIDGEHIP1 AE3-001 2 AE3-001 3 AE3-001 1 AE3-002 2 AE3-002 3 AE3-002 6 AE3-005 3 AE3-005 DRAFTSTOP - VERIFY/COORDINATE LOCATION W/ TRUSS MANUFACTURER - SEE PARTITION TYPE E ON AE5-001 (TYP) DRAFTSTOP - VERIFY/COORDINATE LOCATION W/ TRUSS MANUFACTURER - SEE PARTITION TYPE E ON AE5-001 - TYPICAL PREFINISHED METAL GUTTER & DOWNSPOUTS - TYPICAL LINE OF EXTERIOR WALL BELOW - TYPICAL SOFFIT VENT (TYP) SOFFIT VENT (TYP) SOFFIT LIGHTING (TYP) SOFFIT LIGHTING (TYP) 6:12 6:12 VALLEYVALLEYRIDGE6:12 6:12 VALLEYVALLEYRIDGE6:12 6:12 VALLEYVALLEYRIDGE6:12 6:12 VALLEYVALLEYRIDGEVALLEYVALLEYRIDGE 6:12 6:12 VALLEYVALLEYRIDGE6:12 6:12 RIDGE VENT- TYPICAL AT ALL DORMERS RIDGE VENT HIP VENT (5' LONG) RIDGE VENT RIDGE VENT - TYPICAL AT ALL DORMERS RIDGE VENT RIDGE VENT TYPICAL2' - 0 1/8"LOCATE ALL PLUMBING STACKS NEAR ROOF PLANE. VERIFY THAT NO VENTS ARE VISIBLE FROM THE STREET. PROVIDE PREFINISHED METAL DRIP EDGE AT ALL ROOF EAVES AND RAKES. PROVIDE PREFINISHED 5" METAL GUTTERS AND DOWNSPOUTS - COORDINATE DOWNSPOUT LOCATIONS WITH OWNER & CIVIL ENGINEER IN FIELD. PROVIDE SELF-ADHERED ROOFING UNDERLAYMENT (GRACE ICE & WATER SHIELD OR APPROVED EQUAL) AT ALL EAVES AND VALLEYS 36" PAST THE INTERIOR OF THE EXTERIOR WALL AND UP EACH VALLEY SIDE 18" MINIMUM. PROVIDE SELF-ADHERED ROOFING UNDERLAYEMNT (GRACE ICE & WATER SHIELD OR APPROVED EQUAL) AT ALL DORMERS, TYPICAL. SADDLE SHALL BE SINGLE PLY 60 MIL EPDM WITH PREFINISHED METAL EDGE FLASHING WITH DRIP EDGE. INSTALL IN STRICT COMPLIANCE WITH MANUFACTURER'S INSTALLATION SPECIFICATION. MINIMUM SLOPE TO BE 1/4" PER FOOT. PAINT ALL ROOF PENETRATIONS TO MATCH ROOF. ROOF PLAN NOTES ATTIC "A" VENTILATION CALCULATIONS 1 SF OF ATTIC VENT PER 300 SF OF ATTIC FLOOR AREA (OVER ALL PERIMETER OF ROOF) TOTAL ATTIC SPACE = 2,772 SF 2,772 / 300 = 9.24 SF 9.24 SF / 2 (INTAKE / EXHAUST) = 4.62 SF 4.62 SF X 144 = 665.28 SQ INCHES (NET FREE AREA REQUIRED) VENTILATION EXHAUST CALCULATIONS ROOF RIDGE VENT: SHINGLE VENT II BY AIR VENT, INC = 18 NFA PER LF: 665.28 SQ IN / 18 NFA = 36.96 LF OF RIDGE VENT REQUIRED PROPOSED VENTILATION EXHAUST 47 LF OF RIDGE VENT PROVIDED VENTILATION INTAKE CALCULATIONS 665.28 SQ IN NET FREE AREA REQUIRED AIR VENT UNDER EAVE VENT, 16" X 16" = 42 SQ IN NFA PER UNIT: 665.28 / 42 = 15.84 VENTS REQUIRED PROPOSED VENTILATION REQUIRED 16 VENTS PROVIDED ATTIC "B" VENTILATION CALCULATIONS 1 SF OF ATTIC VENT PER 300 SF OF ATTIC FLOOR AREA (OVER ALL PERIMETER OF ROOF) TOTAL ATTIC SPACE = 2,457 SF 2,457 / 300 = 8.19 SF 8.19 SF / 2 (INTAKE / EXHAUST) = 4.10 SF 4.10 SF X 144 = 590.40 SQ INCHES (NET FREE AREA REQUIRED) VENTILATION EXHAUST CALCULATIONS ROOF RIDGE VENT: SHINGLE VENT II BY AIR VENT, INC = 18 NFA PER LF: 590.40 SQ IN / 18 NFA = 32.8 LF OF RIDGE VENT REQUIRED PROPOSED VENTILATION EXHAUST 72 LF OF RIDGE VENT PROVIDED VENTILATION INTAKE CALCULATIONS 590.40 SQ IN NET FREE AREA REQUIRED AIR VENT UNDER EAVE VENT, 16" X 16" = 42 SQ IN NFA PER UNIT: 590.40 / 42 = 14.06 VENTS REQUIRED PROPOSED VENTILATION REQUIRED 15 VENTS PROVIDED ATTIC "C" VENTILATION CALCULATIONS 1 SF OF ATTIC VENT PER 300 SF OF ATTIC FLOOR AREA (OVER ALL PERIMETER OF ROOF) TOTAL ATTIC SPACE = 2,665 SF 2,665 / 300 = 8.88 SF 8.88 SF / 2 (INTAKE / EXHAUST) = 4.44 SF 4.44 SF X 144 = 639.36 SQ INCHES (NET FREE AREA REQUIRED) VENTILATION EXHAUST CALCULATIONS ROOF RIDGE VENT: SHINGLE VENT II BY AIR VENT, INC = 18 NFA PER LF: 639.36 SQ IN / 18 NFA = 35.52 LF OF RIDGE VENT REQUIRED PROPOSED VENTILATION EXHAUST 47 LF OF RIDGE VENT PROVIDED VENTILATION INTAKE CALCULATIONS 639.36 SQ IN NET FREE AREA REQUIRED AIR VENT UNDER EAVE VENT, 16" X 16" = 42 SQ IN NFA PER UNIT: 639.36 / 42 = 15.22 VENTS REQUIRED PROPOSED VENTILATION REQUIRED 16 VENTS PROVIDED ATTIC "D" VENTILATION CALCULATIONS 1 SF OF ATTIC VENT PER 300 SF OF ATTIC FLOOR AREA (OVER ALL PERIMETER OF ROOF) TOTAL ATTIC SPACE = 2,941 SF 2,941 / 300 = 9.80 SF 9.80 SF / 2 (INTAKE / EXHAUST) = 4.9 SF 4.9 SF X 144 = 705.6 SQ INCHES (NET FREE AREA REQUIRED) VENTILATION EXHAUST CALCULATIONS ROOF RIDGE VENT: SHINGLE VENT II BY AIR VENT, INC = 18 NFA PER LF: 705.6 SQ IN / 18 NFA = 39.2 LF OF RIDGE VENT REQUIRED PROPOSED VENTILATION EXHAUST 90 LF OF RIDGE VENT PROVIDED VENTILATION INTAKE CALCULATIONS 705.6 SQ IN NET FREE AREA REQUIRED AIR VENT UNDER EAVE VENT, 16" X 16" = 42 SQ IN NFA PER UNIT: 705.6 / 42 = 16.8 VENTS REQUIRED PROPOSED VENTILATION REQUIRED 17 VENTS PROVIDED ATTIC "E" VENTILATION CALCULATIONS 1 SF OF ATTIC VENT PER 300 SF OF ATTIC FLOOR AREA (OVER ALL PERIMETER OF ROOF) TOTAL ATTIC SPACE = 2,985 SF 2,985 / 300 = 9.95 SF 9.95 SF / 2 (INTAKE / EXHAUST) = 4.98 SF 4.98 SF X 144 = 717.12 SQ INCHES (NET FREE AREA REQUIRED) VENTILATION EXHAUST CALCULATIONS ROOF RIDGE VENT: SHINGLE VENT II BY AIR VENT, INC = 18 NFA PER LF: 717.12 SQ IN / 18 NFA = 39.84 LF OF RIDGE VENT REQUIRED PROPOSED VENTILATION EXHAUST 45 LF OF RIDGE & HIP VENTS PROVIDED VENTILATION INTAKE CALCULATIONS 717.12 SQ IN NET FREE AREA REQUIRED AIR VENT UNDER EAVE VENT, 16" X 16" = 42 SQ IN NFA PER UNIT: 717.12 / 42 = 17.07 VENTS REQUIRED PROPOSED VENTILATION REQUIRED 18 VENTS PROVIDED Project North True North is a member of the IBI Group of companies DATE: ISSUE SHEET TITLE PROJECT SCALE: APPROVED BY:PROJECT MGR: PROJECT NO: SHEET NUMBER CLIENT COPYRIGHT ISSUES This drawing has been prepared solely for the intended use, thus any reproduction or distribution for any purpose other than authorized by IBI Group is forbidden. Written dimensions shall have precedence over scaled dimensions. Contractors shall verify and be responsible for all dimensions and conditions on the job, and IBI Group shall be informed of any variations from the dimensions and conditions shown on the drawing. Shop drawings shall be submitted to IBI Group for general conformance before proceeding with fabrication. IBI Group Engineering Services (USA) Inc. CHECKED BY:DRAWN BY:SCALE CHECKSEAL 3221 W Big Beaver, Suite 111 Troy, MI, 48084 10mm1 in CONSULTANTS 3/16" = 1'-0" 0 C:\Users\heather.gulla\Documents\REVIT2018\122885_814KC CrmlIN_arch_v18_roofedit_heather.gulla.rvtROOF PLAN 122885 M.STOCK 2020-02-19 AE1-300 KINDERCARE LEARNING CENTER L.SMIGLIANI CARMEL, IN C.GREER E.SHELINE SCALE: 3/16" = 1'-0" ROOF PLAN1 ATTIC VENTILATION CALCULATIONS No. DESCRIPTION DATE 0 PERMIT 2020-08-04 10/29/20