HomeMy WebLinkAboutAE3-006-SECTIONS,-DETAILS6"1' - 6"
5' - 2" @ SINGLE EXTERIOR DOORSLOPE2% MAX5' - 0" MINIMUMCONCRETE
LANDING
3
AE3-003
SIM
FOUNDATION
WALL TYP 3 SIDES
5"2' - 0" 5"
TYP
3" MIN
TYP3" MINSIGNAGE AND BASE CONNECTION BY
OTHERS. CONTRACTOR TO PROVIDE
SIGNED & SEALED CALCULATIONS
FOR SIGN CONNECTION.
TYP
3" MIN TYP3" MIN#5 BARS TRANSVERSE
@ 6" O.C. TOP & BOTTOM
5 -#5 BARS TOP &
BOTTOM CONTINUOUS3' - 6" 2' - 0"#5 BARS @ 16" O.C.
EACH FACE
8" CMU BOND BEAM W/
2 - #5 BARS CONT
LIMESTONE CAP M-7
GRADE LINE
BRICK VENEER M-1 TYP3" MIN8" CMU WALL W/ #5 BARS
@ 16" OC
GROUT ALL CORES SOLID
SIGN AND LIMESTONE CAP
CONNECTIONS TO BE PLACED INTO
THE CENTER OF THE CMU BOND
BEAMS W/ MIN 2" EDGE DISTANCE
1/2" SOLID CELLULAR PVC
SHEET ON AIR/MOISTURE
BARRIER ON 1/2" APA RATED
SHEATHING ON 2X4 WOOD
STUD FRAMING AT 16" ON
CENTER
5/8" GYPSUM BOARD
INSULATION
1/2" SOLID CELLULAR PVC
SHEET ON AIR/MOISTURE
BARRIER ON 1/2" APA RATED
SHEATHING ON 2X4 WOOD
STUD FRAMING AT 16" ON
CENTER
HORIZONTAL LAP SIDING
ON AIR/MOISTURE
BARRIER ON 1/2" APA
RATED SHEATHING ON 2X4
WOOD STUD FRAMING AT
16" ON CENTER 4"SIDE
FRONT
BUTT JOINT ENDS WITH
CLEAR WEATHERTIGHT
SEALANT
Project North True North
is a member of the IBI Group of companies
DATE:
ISSUE
SHEET TITLE
PROJECT
SCALE:
APPROVED BY:PROJECT MGR:
PROJECT NO:
SHEET NUMBER
CLIENT
COPYRIGHT
ISSUES
This drawing has been prepared solely for the intended use, thus any reproduction
or distribution for any purpose other than authorized by IBI Group is forbidden.
Written dimensions shall have precedence over scaled dimensions. Contractors
shall verify and be responsible for all dimensions and conditions on the job, and IBI
Group shall be informed of any variations from the dimensions and conditions
shown on the drawing. Shop drawings shall be submitted to IBI Group for general
conformance before proceeding with fabrication.
IBI Group Engineering Services (USA) Inc.
CHECKED BY:DRAWN BY:SCALE CHECKSEAL
3221 W Big Beaver, Suite 111
Troy, MI, 48084
10mm1 in CONSULTANTS
As indicated
0 C:\Users\heather.gulla\Documents\REVIT2018\122885_814KC CrmlIN_arch_v18_roofedit_heather.gulla.rvtSECTIONS, DETAILS
122885
M.STOCK
2020-02-19
AE3-006
KINDERCARE LEARNING
CENTER
L.SMIGLIANI
CARMEL, IN
C.GREER E.SHELINE
FOR
R
E
F
E
R
E
N
C
E ONLY
AE3-006 Scale: 3/4" = 1'-0"
2 CONCRETE DOOR PAD PLAN
AE3-006 Scale: 1" = 1'-0"
1 FOUNDATION DETAIL FOR EXTERIOR SIGNAGE
No. DESCRIPTION DATE
0 PERMIT 2020-08-04
AE3-006 Scale: 1 1/2" = 1'-0"
4 CUPOLA PLAN CORNER DETAIL
AE3-006 Scale: 1 1/2" = 1'-0"
3 DORMER PLAN CORNER DETAIL
10/29/20