Loading...
HomeMy WebLinkAboutEnvelope ComCheck_Carmel_INCOMcheck Software Version 4.1.3.0 Envelope Compliance Certificate Project Title: 90.1 (2007) Standard Project Type:New Construction Vertical Glazing / Wall Area:16% Location:Carmel, Indiana Climate Zone:5a Construction Site: 10940 North Michigan Road Carmel, IN 46032 Owner/Agent: 814 Development LLC Designer/Contractor: IBI Group Project Information Energy Code: KinderCare Building Area Floor Area 1-School/University : Nonresidential 11985 Envelope Assemblies Assembly Cavity R-Value Cont. R-Value Proposed U-Factor Budget U- Factor(a) Gross Area or Perimeter Floor 1: Slab-On-Grade:Unheated, Vertical 2 ft., [Bldg. Use 1 - School/University] (c) 558 ---10.0 0.540 0.540 Roof 1: Attic Roof with Wood Joists, [Bldg. Use 1 - School/University]14020 38.0 0.0 0.027 0.027 NORTH North Elevation: Wood-Framed, 16" o.c., [Bldg. Use 1 - School/University] 2048 19.0 0.0 0.067 0.064 Window 1: Vinyl/Fiberglass Frame, Perf. Specs.: Product ID NA, SHGC 0.58, PF 0.26, VT 0.70, [Bldg. Use 1 - School/University] (b) 25 ------0.450 0.350 Window 1 copy 1: Vinyl/Fiberglass Frame, Perf. Specs.: Product ID NA, SHGC 0.58, PF 0.26, VT 0.70, [Bldg. Use 1 - School/University] (b) 25 ------0.450 0.350 Window 1 copy 2: Vinyl/Fiberglass Frame, Perf. Specs.: Product ID NA, SHGC 0.58, PF 0.26, VT 0.70, [Bldg. Use 1 - School/University] (b) 25 ------0.450 0.350 Window 1 copy 3: Vinyl/Fiberglass Frame, Perf. Specs.: Product ID NA, SHGC 0.58, PF 0.26, VT 0.70, [Bldg. Use 1 - School/University] (b) 25 ------0.450 0.350 Window 1 copy 4: Vinyl/Fiberglass Frame, Perf. Specs.: Product ID NA, SHGC 0.58, PF 0.26, VT 0.70, [Bldg. Use 1 - School/University] (b) 25 ------0.450 0.350 Window 1 copy 5: Vinyl/Fiberglass Frame, Perf. Specs.: Product ID NA, SHGC 0.58, PF 0.26, VT 0.70, [Bldg. Use 1 - School/University] (b) 25 ------0.450 0.350 Window 1 copy 6: Vinyl/Fiberglass Frame, Perf. Specs.: Product ID NA, SHGC 0.58, PF 0.26, VT 0.70, [Bldg. Use 1 - School/University] (b) 25 ------0.450 0.350 Window 1 copy 7: Vinyl/Fiberglass Frame, Perf. Specs.: Product ID NA, SHGC 0.58, PF 0.26, VT 0.70, [Bldg. Use 1 - School/University] (b) 25 ------0.450 0.350 Door 1: Glass (> 50% glazing):Metal Frame, Entrance Door, Perf. Specs.: Product ID NA, SHGC 0.58, PF 0.73, VT 0.70, [Bldg. Use 1 - School/University] (b) 63 ------0.770 0.800 Door 2: Glass (> 50% glazing):Metal Frame, Non-Entrance Door, Perf. Specs.: Product ID NA, SHGC 0.40, PF 0.26, VT 0.70, [Bldg. Use 1 - School/University] (b) 21 ------0.550 0.550 Door 3: Glass (> 50% glazing):Metal Frame, Non-Entrance Door, Perf. Specs.: Product ID NA, SHGC 0.40, PF 0.26, VT 0.70, [Bldg. Use 1 - 21 ------0.550 0.550 Project Title: Data filename: KinderCare J:\122885_814KC CrmlIN\6.0_Technical\6.1_Arch\6.1.3_Tech-Reports\122875_ComCheck.cck 09/01/20Report date: 101 ofPage Assembly Cavity R-Value Cont. R-Value Proposed U-Factor Budget U- Factor(a) Gross Area or Perimeter School/University] (b) Door 4: Glass (> 50% glazing):Metal Frame, Non-Entrance Door, Perf. Specs.: Product ID NA, SHGC 0.40, PF 0.26, VT 0.70, [Bldg. Use 1 - School/University] (b) 21 ------0.550 0.550 Door 5: Glass (> 50% glazing):Metal Frame, Non-Entrance Door, Perf. Specs.: Product ID NA, SHGC 0.40, PF 0.26, VT 0.70, [Bldg. Use 1 - School/University] (b) 21 ------0.550 0.550 EAST East Elevation: Wood-Framed, 16" o.c., [Bldg. Use 1 - School/University] 1005 19.0 0.0 0.067 0.064 Window 1: Vinyl/Fiberglass Frame, Perf. Specs.: Product ID NA, SHGC 0.48, PF 0.26, VT 0.70, [Bldg. Use 1 - School/University] (b) 25 ------0.450 0.350 Window 1 copy 1: Vinyl/Fiberglass Frame, Perf. Specs.: Product ID NA, SHGC 0.48, PF 0.26, VT 0.70, [Bldg. Use 1 - School/University] (b) 25 ------0.450 0.350 Window 1 copy 2: Vinyl/Fiberglass Frame, Perf. Specs.: Product ID NA, SHGC 0.48, PF 0.26, VT 0.70, [Bldg. Use 1 - School/University] (b) 30 ------0.380 0.350 Window 1 copy 3: Vinyl/Fiberglass Frame, Perf. Specs.: Product ID NA, SHGC 0.48, PF 0.26, VT 0.70, [Bldg. Use 1 - School/University] (b) 30 ------0.380 0.350 Door 1: Glass (> 50% glazing):Metal Frame, Non-Entrance Door, Perf. Specs.: Product ID NA, SHGC 0.40, PF 0.26, VT 0.70, [Bldg. Use 1 - School/University] (b) 21 ------0.550 0.550 Door 2: Glass (> 50% glazing):Metal Frame, Non-Entrance Door, Perf. Specs.: Product ID NA, SHGC 0.40, PF 0.26, VT 0.70, [Bldg. Use 1 - School/University] (b) 21 ------0.550 0.550 Door 3: Glass (> 50% glazing):Metal Frame, Non-Entrance Door, Perf. Specs.: Product ID NA, SHGC 0.40, PF 0.26, VT 0.70, [Bldg. Use 1 - School/University] (b) 21 ------0.550 0.550 SOUTH South Elevation: Wood-Framed, 16" o.c., [Bldg. Use 1 - School/University] 2086 19.0 0.0 0.067 0.064 Window 1: Vinyl/Fiberglass Frame, Perf. Specs.: Product ID NA, SHGC 0.48, PF 0.26, VT 0.70, [Bldg. Use 1 - School/University] (b) 25 ------0.450 0.350 Window 1 copy 1: Vinyl/Fiberglass Frame, Perf. Specs.: Product ID NA, SHGC 0.48, PF 0.26, VT 0.70, [Bldg. Use 1 - School/University] (b) 25 ------0.450 0.350 Window 1 copy 2: Vinyl/Fiberglass Frame, Perf. Specs.: Product ID NA, SHGC 0.48, PF 0.26, VT 0.70, [Bldg. Use 1 - School/University] (b) 25 ------0.450 0.350 Window 1 copy 3: Vinyl/Fiberglass Frame, Perf. Specs.: Product ID NA, SHGC 0.48, PF 0.26, VT 0.70, [Bldg. Use 1 - School/University] (b) 25 ------0.450 0.350 Window 1 copy 4: Vinyl/Fiberglass Frame, Perf. Specs.: Product ID NA, SHGC 0.48, PF 0.26, VT 0.70, [Bldg. Use 1 - School/University] (b) 25 ------0.450 0.350 Window 1 copy 5: Vinyl/Fiberglass Frame, Perf. Specs.: Product ID NA, SHGC 0.48, PF 0.26, VT 0.70, [Bldg. Use 1 - School/University] (b) 25 ------0.450 0.350 Window 7 copy 1: Vinyl/Fiberglass Frame, Perf. Specs.: Product ID NA, SHGC 0.64, PF 0.79, VT 0.70, [Bldg. Use 1 - School/University] (b) 15 ------0.380 0.350 Window 7 copy 2: Vinyl/Fiberglass Frame, Perf. Specs.: Product ID NA, SHGC 0.64, PF 0.79, VT 0.70, [Bldg. Use 1 - School/University] (b) 15 ------0.380 0.350 Window 7: Vinyl/Fiberglass Frame, Perf. Specs.: Product ID NA, SHGC 0.64, PF 0.79, VT 0.70, [Bldg. Use 1 - School/University] (b) 15 ------0.380 0.350 Window 7 copy 3: Vinyl/Fiberglass Frame, Perf. Specs.: Product ID NA, SHGC 0.64, PF 0.79, VT 0.70, [Bldg. Use 1 - School/University] (b) 15 ------0.380 0.350 Window 7 copy 4: Vinyl/Fiberglass Frame, Perf. Specs.: Product ID NA, SHGC 0.64, PF 0.79, VT 0.70, [Bldg. Use 1 - School/University] (b) 15 ------0.380 0.350 Door 1: Glass (> 50% glazing):Metal Frame, Non-Entrance Door, Perf. Specs.: Product ID NA, SHGC 0.40, PF 0.26, VT 0.70, [Bldg. Use 1 - School/University] (b) 21 ------0.550 0.550 Door 2: Glass (> 50% glazing):Metal Frame, Non-Entrance Door, Perf. Specs.: Product ID NA, SHGC 0.40, PF 0.26, VT 0.70, [Bldg. Use 1 - School/University] (b) 21 ------0.550 0.550 Project Title: Data filename: KinderCare J:\122885_814KC CrmlIN\6.0_Technical\6.1_Arch\6.1.3_Tech-Reports\122875_ComCheck.cck 09/01/20Report date: 102 ofPage Inspection Checklist Requirements: 100.0% were addressed directly in the COMcheck software COMcheck Software Version 4.1.3.0 Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Energy Code: 90.1 (2007) Standard Section # & Req.ID Plan Review Complies?Comments/Assumptions 4.2.2 [PR1]1 Plans and/or specifications provide all information with which compliance can be determined for the building envelope and document where exceptions to the standard are claimed. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: KinderCare J:\122885_814KC CrmlIN\6.0_Technical\6.1_Arch\6.1.3_Tech-Reports\122875_ComCheck.cck 09/01/20Report date: 104 ofPage Section # & Req.ID Footing / Foundation Inspection Plans Verified Value Field Verified Value Complies?Comments/Assumptions 5.5.3.3 [FO1]1 Below-grade wall insulation R- value. R-_____R-_____Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 5.5.3.5 [FO3]1 Slab edge insulation R-value.R-_____ Unheated Heated R-_____ Unheated Heated Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 5.8.1.2 [FO4]1 Slab edge insulation installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable Requirement will be met. 5.5.3.5 [FO5]1 Slab edge insulation depth/length. _____ ft _____ ft Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 5.8.1.7.3 [FO7]1 Insulation in contact with the ground has <=0.3% water absorption rate per ASTM C272. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: KinderCare J:\122885_814KC CrmlIN\6.0_Technical\6.1_Arch\6.1.3_Tech-Reports\122875_ComCheck.cck 09/01/20Report date: 105 ofPage Section # & Req.ID Framing / Rough-In Inspection Plans Verified Value Field Verified Value Complies?Comments/Assumptions 5.4.3.2 [FR1]3 Factory-built fenestration and doors are labeled as meeting air leakage requirements. Fenestration____ _ cfm/ft2 Doors_____ cfm/ft2 Fenestration____ _ cfm/ft2 Doors_____ cfm/ft2 Complies Does Not Not Observable Not Applicable Requirement will be met. 5.4.3.4 [FR4]3 Vestibules are installed where building entrances separate conditioned space from the exterior, and meet exterior envelope requirements. Doors have self-closing devices, and are >=7 ft apart. Complies Does Not Not Observable Not Applicable Requirement will be met. 5.5.4.3a [FR8]1 Vertical fenestration U-Factor.U-_____U-_____Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 5.5.4.3b [FR9]1 Skylight fenestration U-Factor.U-_____U-_____Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 5.5.4.4.1 [FR10]1 Vertical fenestration SHGC value.SHGC:_____SHGC:_____Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 5.5.4.4.2 [FR11]1 Skylight SHGC value.SHGC:_____SHGC:_____Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 5.8.2.1, 5.8.2.4 [FR12]2 Fenestration products rated in accordance with NFRC. Complies Does Not Not Observable Not Applicable Requirement will be met. 5.8.2.2 [FR13]1 Fenestration products are certified as to performance labels or certificates provided. Complies Does Not Not Observable Not Applicable Requirement will be met. 5.8.2.3, 5.5.3.6 [FR14]2 U-factor of opaque doors associated with the building thermal envelope meets requirements. U-_____ Swinging Nonswinging U-_____ Swinging Nonswinging Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: KinderCare J:\122885_814KC CrmlIN\6.0_Technical\6.1_Arch\6.1.3_Tech-Reports\122875_ComCheck.cck 09/01/20Report date: 106 ofPage Section # & Req.ID Insulation Inspection Plans Verified Value Field Verified Value Complies?Comments/Assumptions 5.4.3.1 [IN1]1 All sources of air leakage in the building thermal envelope are sealed, caulked, gasketed, weather stripped or wrapped with moisture vapor-permeable wrapping material to minimize air leakage. Complies Does Not Not Observable Not Applicable Requirement will be met. 5.5.3.1 [IN2]1 Roof R-value. For some ceiling systems, verification may need to occur during Framing Inspection. R-_____ Above deck Metal Attic R-_____ Above deck Metal Attic Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 5.8.1.2, 5.8.1.3 [IN3]1 Roof insulation installed per manufacturer’s instructions. Blown or poured loose-fill insulation is installed only where the ceiling slope is <= 3:12. Complies Does Not Not Observable Not Applicable Requirement will be met. 5.5.3.1.1 [IN5]3 High-albedo roofs meet solar reflectance of 0.70 and thermal emittance of 0.75 or SRI of 82. SR:_____ SRI:_____ SR:_____ SRI:_____ Complies Does Not Not Observable Not Applicable Requirement will be met. 5.5.3.2 [IN6]1 Above-grade wall insulation R- value. R-_____ Mass Metal Steel Wood R-_____ Mass Metal Steel Wood Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 5.8.1.2 [IN7]1 Above-grade wall insulation installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable Requirement will be met. 5.5.3.4 [IN8]1 Floor insulation R-value.R-_____ Mass Steel Wood R-_____ Mass Steel Wood Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 5.8.1.1 [IN10]2 Building envelope insulation is labeled with R-value or insulation certificate providing R-value and other relevant data. Complies Does Not Not Observable Not Applicable Requirement will be met. 5.8.1.4 [IN11]2 Eaves are baffled to deflect air to above the insulation. Complies Does Not Not Observable Not Applicable Requirement will be met. 5.8.1.5 [IN12]2 Insulation is installed in substantial contact with the inside surface separating conditioned space from unconditional space. Complies Does Not Not Observable Not Applicable Requirement will be met. 5.8.1.6 [IN13]2 Recessed equipment installed in building envelope assemblies does not compress the adjacent insulation. Complies Does Not Not Observable Not Applicable Requirement will be met. 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: KinderCare J:\122885_814KC CrmlIN\6.0_Technical\6.1_Arch\6.1.3_Tech-Reports\122875_ComCheck.cck 09/01/20Report date: 107 ofPage Section # & Req.ID Insulation Inspection Plans Verified Value Field Verified Value Complies?Comments/Assumptions 5.8.1.7 [IN14]2 Exterior insulation is protected from damage with a protective material. Verification for exposed foundation insulation may need to occur during Foundation Inspection. Complies Does Not Not Observable Not Applicable Requirement will be met. 5.8.1.7.1 [IN15]2 Attics and mechanical rooms have insulation protected where adjacent to attic or equipment access. Complies Does Not Not Observable Not Applicable Requirement will be met. 5.8.1.7.2 [IN16]2 Foundation vents do not interfere with insulation. Complies Does Not Not Observable Not Applicable Requirement will be met. 5.8.1.8 [IN17]3 Insulation intended to meet the roof insulation requirements cannot be installed on top of a suspended ceiling. Mark this requirement compliant if insulation is installed accordingly. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: KinderCare J:\122885_814KC CrmlIN\6.0_Technical\6.1_Arch\6.1.3_Tech-Reports\122875_ComCheck.cck 09/01/20Report date: 108 ofPage Section # & Req.ID Final Inspection Complies?Comments/Assumptions 5.4.3.3 [FI1]1 Weatherseals installed on all loading dock cargo doors in Climate Zones 4- 8. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: KinderCare J:\122885_814KC CrmlIN\6.0_Technical\6.1_Arch\6.1.3_Tech-Reports\122875_ComCheck.cck 09/01/20Report date: 109 ofPage Project Title: Data filename: KinderCare J:\122885_814KC CrmlIN\6.0_Technical\6.1_Arch\6.1.3_Tech-Reports\122875_ComCheck.cck 09/01/20Report date: 1010 ofPage