HomeMy WebLinkAboutExterior_Lighting_Comcheck_Report_Carmel_SignedCOMcheck Software Version 4.1.1.0
Exterior Lighting Compliance Certificate
Project Title:
90.1 (2007) Standard
Project Type:New Construction
Construction Site:
Carmel, IN
Owner/Agent:
Kindercare Learning Center
Designer/Contractor:
Lindsay Zanders
WSP
30 N. LaSalle St.
Suite 4200
Chicago, IL 60602
Project Information
Energy Code:
Kindercare Learning Center
Allowed Exterior Lighting Power
A
Area/Surface Category
B
Quantity
C
Allowed
Watts / Unit
D
Tradable
Wattage
E
Allowed Watts
(B X C)
Main Parking Lot (Parking area(s))23150 ft2 0.15 Yes 3472
Building Canopy (Attached canopy)4100 ft2 1.25 Yes 5125
Main Entrance (Main entry/exit)3 ft of door 30 Yes 90
Building Exits (Other entry/exit)45 ft of door 20 Yes 900
Main Entrance (Illuminated length of wall or surface)17 ft 5 No 85
Total Tradable Watts (a) =
Total Allowed Watts =
Total Allowed Supplemental Watts (b) =
9588
9672
484
(a)Wattage tradeoffs are only allowed between tradable areas/surfaces.
(b)A supplemental allowance equal to 484 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces.
Proposed Exterior Lighting Power
E
(C X D)
D
Fixture
Watt.
A
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast
B
Lamps/
Fixture
C
# of
Fixtures
Main Parking Lot ( Parking area(s) 23150 ft2): Tradable Wattage
LED 5: N1: LED Roadway-Parking Unit 67W:1 5 70 350
LED 5 copy 1: N2: LED Roadway-Parking Unit 67W:1 2 70 140
LED 5 copy 2: N3: LED Roadway-Parking Unit 67W:1 2 70 140
LED 5 copy 3: N4: LED Roadway-Parking Unit 67W:1 2 70 140
LED 5 copy 4: N5: LED Roadway-Parking Unit 54W:1 2 54 108
Building Canopy ( Attached canopy 4100 ft2): Tradable Wattage
LED 4: G: LED A Lamp 25W:1 9 35 315
Main Entrance ( Main entry/exit 3 ft of door width): Tradable Wattage
LED 2: G: LED A Lamp 25W:1 2 35 70
Building Exits ( Other entry/exit 45 ft of door width): Tradable Wattage
LED 1: G: Downlight: LED A Lamp 25W:1 15 35 525
Main Entrance ( Illuminated length of wall or surface 17 ft): Non-tradable Wattage
LED 3: F: LED A Lamp 12W:1 2 12 24
1788Total Tradable Proposed Watts =
Project Title:
Data filename:
Kindercare Learning Center
P:\2018 Projects\1811065.011 Carmel IN Kindercare\6_ENG-LTNG\CALCS\ENERGY\Kindercare
Carmel Exterior comcheck.cck
09/01/20Report date:
51 ofPage
Exterior Lighting Compliance Statement
Compliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans,
specifications, and other calculations submitted with this permit application. The proposed exterior lighting systems have been
designed to meet the 90.1 (2007) Standard requirements in COMcheck Version 4.1.1.0 and to comply with any applicable
mandatory requirements listed in the Inspection Checklist.
Name - Title Signature Date
Exterior Lighting PASSES: Design 82% better than code
Project Title:
Data filename:
Kindercare Learning Center
P:\2018 Projects\1811065.011 Carmel IN Kindercare\6_ENG-LTNG\CALCS\ENERGY\Kindercare
Carmel Exterior comcheck.cck
09/01/20Report date:
52 ofPage
Lindsay Zanders 8/4/2020
Inspection Checklist
Requirements: 100.0% were addressed directly in the COMcheck software
COMcheck Software Version 4.1.1.0
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Energy Code: 90.1 (2007) Standard
Section
#
& Req.ID
Rough-In Electrical Inspection Complies?Comments/Assumptions
9.4.1.3
[EL3]2
Automatic lighting controls for exterior
lighting installed.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
9.4.4
[EL7]1
Exterior grounds lighting over 100 W
provides >60 lm/W unless on motion
sensor or fixture is exempt from scope
of code or from external LPD.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Kindercare Learning Center
P:\2018 Projects\1811065.011 Carmel IN Kindercare\6_ENG-LTNG\CALCS\ENERGY\Kindercare
Carmel Exterior comcheck.cck
09/01/20Report date:
53 ofPage
Section
#
& Req.ID
Final Inspection Complies?Comments/Assumptions
9.4.5
[FI19]1
Exterior lighting power is consistent
with what is shown on the approved
lighting plans, demonstrating
proposed watts are less than or equal
to allowed watts.
Complies
Does Not
Not Observable
Not Applicable
See the Exterior Lighting fixture schedule for values.
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Kindercare Learning Center
P:\2018 Projects\1811065.011 Carmel IN Kindercare\6_ENG-LTNG\CALCS\ENERGY\Kindercare
Carmel Exterior comcheck.cck
09/01/20Report date:
54 ofPage
Project Title:
Data filename:
Kindercare Learning Center
P:\2018 Projects\1811065.011 Carmel IN Kindercare\6_ENG-LTNG\CALCS\ENERGY\Kindercare
Carmel Exterior comcheck.cck
09/01/20Report date:
55 ofPage