HomeMy WebLinkAboutFP-001-FIRE-PROTECTION-COVER-SHEETFIRE PROTECTION COVER SHEET FP-001 is a member of the IBI Group of companies DATE: ISSUE SHEET TITLE PROJECT SCALE: APPROVED BY:PROJECT MGR: PROJECT NO: SHEET NUMBER CLIENT COPYRIGHT ISSUES This drawing has been prepared solely for the intended use, thus any reproduction or distribution for any purpose other than authorized by IBI Group is forbidden. Written dimensions shall have precedence over scaled dimensions. Contractors shall verify and be responsible for all dimensions and conditions on the job, and IBI Group shall be informed of any variations from the dimensions and conditions shown on the drawing. Shop drawings shall be submitted to IBI Group for general conformance before proceeding with fabrication. IBI Group - Michigan LLC CHECKED BY:DRAWN BY: SCALE CHECKSEAL 3221 W Big Beaver, Suite 111 Troy, MI, 48084 10mm1 in Carmel, IN CONSULTANTS 122885 LZ 08/04/2020 KINDERCARE LEARNING CENTER LZ CAD LZ No. DESCRIPTION DATE As Indicated A ZONING/PLAN APPROVAL 2020-05-04 0 B 100% CD 2020-07-31 0 PERMIT 2020-08-04 1 M T S S ACV GA F SP FSP DR SPRINKLER WORK NOTES 1. THE FIRE PROTECTION CONTRACT DRAWINGS ARE THE "PRELIMINARY PLANS" DEFINED BY NFPA 13, A.14.1 PREPARED FOR PRELIMINARY SUBMISSION FOR BID DOCUMENTS. THE CONTRACT DRAWINGS INDICATE A PARTIAL DESIGN AND SPECIFY THE DESIGN CRITERIA TO BE USED BY THE INSTALLING CONTRACTOR WHO FINALIZES THE SYSTEM LAYOUT AND PROVIDES HYDRAULIC CALCULATIONS. THE PRELIMINARY PLANS ONLY SHOW THE "TENTATIVE LOCATION OF MAJOR PIPING INCLUDING MAINS, RISERS, OVERHEAD MAINS AND FIRE DEPARTMENT CONNECTIONS." THE SPRINKLER AND PIPING LAYOUTS AND PIPE SIZES SHOWN ON THE CONTRACT DRAWINGS ARE TO DEFINE THE BASIC SCOPE FOR PERMITTING AND ARE NOT INTENDED TO BE COMPLETE TAKE OFF BID DOCUMENTS FOR COMPETITIVE BIDDING. THE DRAWINGS ARE DIAGRAMMATIC AND SHALL BE USED IN CONJUNCTION WITH THE SPECIFIED REQUIREMENTS TO PROVIDE COMPLETE, FULLY FUNCTIONAL AND CODE COMPLIANT SYSTEMS. 2. THE WORK OF THE FIRE PROTECTION CONTRACT INCLUDES: - PREPARATION OF WORKING (FABRICATION) DRAWINGS AS DEFINED BY NFPA 13. - COMPLETE SPRINKLER PROTECTION IN COMPLIANCE WITH NFPA 13. - COMPLETE STANDPIPE SYSTEMS IN COMPLIANCE WITH NFPA 14. - HYDRAULIC CALCULATIONS FOR THE ACTUAL INSTALLATION CONDITIONS BASED ON THE COORDINATION DRAWINGS. - COORDINATION WITH OTHER TRADES. - ON SITE FIELD SURVEY, MEASUREMENT, DESIGN AND FABRICATION. - HYDRANT FLOW TESTING TO CONFIRM AVAILABLE WATER SUPPLY. FLOW TEST REPORT LOCATION: DATE: TEST MADE BY: TIME: REPRESENTATIVE OF: FLOW HYDRANT NO'S: SIZE NOZZLE; " STATIC: PITOT READING: GPM: TIME: FLOW HYDRANT NO'S: SIZE NOZZLE: STATIC: RESIDUAL: REFER TO CIVIL DRAWINGS FOR HYDRANT LOCATIONS. MISCELLANEOUS P = SAN, VENT STACK OR DOMESTIC WATER RISER ST = STORM DRAIN LEADER RISER F = FIRE STANDPIPE RISER EQUIPMENT DESIGNATION DETAIL DESIGNATION SHEET NOTE NUMBER REVISION NUMBER SYMBOL LEGEND Y STRAINER WITH BLOW OFF VALVE PRESSURE GAUGE AND COCK WATER FLOW SWITCH BASKET STRAINER VALVE (SPECIFICATION FOR TYPE) CHECK VALVE PRESSURE REDUCING VALVE OS&Y (OUTSIDE SCREW & YOKE) VALVE AUTOMATIC FLOW CONTROL VALVE BUTTERFLY VALVE (MANUAL) GLOBE VALVE VALVE WITH TAMPER SWITCH SEISMIC VALVE RELIEF VALVE ANGLE RELIEF VALVE FIRE DEPARTMENT CONNECTION FIRE DEPARTMENT TEST HEADER FIRE HOSE VALVE FIRE HOSE VALVE CABINET FIRE DEPT. HOSE VALVE W/ CAP & CHAIN ROOF MANIFOLD SPRINKLER FLOOR CONTROL VALVE ASSEMBLY NEW FIRE HYDRANT EXISTING FIRE HYDRANT TAMPER SWITCH SMOKE DETECTOR ABOVE FLOOR SMOKE DETECTOR BELOW FLOOR ALARM CHECK VALVE W/ ALL RELATED APPURTENANCES GRAPHIC ANNUNCIATOR PANEL SYMBOL LEGEND HYDRAULIC REF. POINTS (ELEMENT) HYDRAULIC REF. POINTS (NODE) UPRIGHT SPRINKLER HEAD PENDANT SPRINKLER HEAD CONCEALED PENDANT SPRINKLER HEAD SIDEWALL SPRINKLER HEAD EXTENDED COVERAGE SPRINKLER HEAD BOTTOM PIPE CONNECTION TOP PIPE CONNECTION VALVE IN VERTICAL PIPE DOWN PIPE UP CAP CHANGE IN PIPE ELEVATION ARROW INDICATES DIRECTION OF FLOW PITCH PIPE DOWN IN DIRECTION OF ARROW INSULATED AND HEAT TRACED PIPING WALL HYDRANT ABBREVIATIONS AFF ABOVE FINISHED FLOOR AP ACCESS PANEL BLDG BUILDING BOP BOTTOM OF PIPE CI CAST IRON CLG CEILING CONN CONNECTION CONT CONTINUATION CV CHECK VALVE DIA DIAMETER DN DOWN DROP DROP (WITHIN FLOOR) DSP DRY SPRINKLER DFS DRY FIRE STANDPIPE DWG DRAWING EL ELEVATION FD FLOOR DRAIN FDC FIRE DEPARTMENT CONNECTION FHC FIRE HOSE CABINET FHR FIRE HOSE RACK FHV FIRE HOSE VALVE FHVC FIRE HOSE VALVE CABINET FL FLOOR FLH FLOOR HYDRANT FP FIRE PUMP FS FLOW SWITCH FSK FLOOR SINK FSP FIRE STANDPIPE FT FEET GAL GALLONS GPM GALLONS PER MINUTE GV GATE VALVE HD HUB DRAIN HT HEAT TRACING ID INSIDE DIAMETER IE INVERT ELEVATION IN INCH IW INDIRECT WASTE JP JOCKEY PUMP MH MANHOLE MIN MINIMUM (N) NEW NC NORMALLY CLOSED NIC NOT IN THIS CONTRACT ABBREVIATIONS NO NORMALLY OPEN OD OUTSIDE DIAMETER OS&Y OUTSIDE SCREW & YOKE GATE VALVE POC POINT OF CONNECTION PRV PRESSURE REDUCING VALVE PSI POUNDS PER SQUARE INCH PSIG POUNDS PER SQUARE INCH (GAUGE) RISE RISE (WITH IN FLOOR) SD SMOKE DETECTOR SF SQUARE FEET SPKR SPRINKLER SSV SEISMIC SAFETY VALVE TDH TOTAL DISCHARGE HEAD TOP TOP OF PIPE TOS TOP OF SLAB TS TAMPER SWITCH TYP TYPICAL UON UNLESS OTHERWISE NOTED UP UP (PENETRATES FLOOR SLAB) Z ZONE PIPING LEGEND FIRE PROTECTION FIRE WATER SUPPLY SPRINKLER PIPING FIRE STANDPIPE SPRINKLER DRAIN PIPING METER # # P 1 CP 1 1 RISER NO. RISER EQUIPMENT EQUIPMENT NO. DWG. SHEET NO. DETAIL NUMBER1 P2.1 FIRE PROTECTION GENERAL NOTES 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. SCOPE: PROVIDE AND INSTALL ALL FIRE PROTECTION WORK AS INDICATED FOR A COMPLETE WORKING SYSTEM. INFORMATION ON THE PLANS IS DIAGRAMMATIC. CONTRACTOR IS RESPONSIBLE FOR DETERMINING FINAL PIPE ROUTING, PIPE SIZING, AND SPRINKLER HEAD LOCATIONS. PERMITS, LICENSES AND FEES: THIS CONTRACTOR SHALL PAY ALL REQUIRED FEES AND SHALL OBTAIN ALL NECESSARY PERMITS AND LICENSES FOR INSTALLATION OF THE WORK TO COMPLETION. APPLICABLE CODES AND REGULATIONS: ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE FOLLOWING CODES AND REGULATIONS: COORDINATE WORK WITH ALL TRADES. PROVIDE A COMPLETE HYDRAULICALLY CALCULATED WET PIPE AUTOMATIC SYSTEM FOR TENANT SPACE, WHICH SHALL BE FULLY SPRINKLERED. ALL PIPING AND EQUIPMENT SHALL BE ADEQUATELY SIZED BASED ON HYDRAULIC CALCULATIONS. GENERAL NOTES, DRAWINGS AND SPECIFICATIONS BY THE ARCHITECT SHALL APPLY TO SPRINKLER SCOPE. ALL MATERIAL NOT TO BE USED AND ALL DEBRIS SHALL BE REMOVED FROM SITE AND THE AREA OF WORK SHALL BE LEFT IN CLEAN CONDITION. INSTALLATION OF ALL PIPING, INSULATION, SPRINKLER HEADS AND EQUIPMENT SHALL BE PERFORMED IN A NEAT AND ORKMANLIKE MANNER, SHALL CONFORM TO THE LATEST TRADE PRACTICES AND SHALL BE FULLY COORDINATED WITH THE WORK OF ALL OTHER TRADES. ALL PIPING SHALL BE INSTALLED AS HIGH AS POSSIBLE UNLESS OTHERWISE NOTED WHILE MAINTAINING PROPER SLOPES AND ALLOWING FOR DUCTWORK, LIGHTING, STRUCTURAL BEAMS, ETC. FLEXIBLE CONNECTIONS SHALL BE PROVIDED FOR PIPING CROSSING EXPANSION JOINTS WHERE INSUFFICIENT FLEXIBILITY EXISTS. PIPE SLEEVES: PIPE SLEEVES AND PIPING INSTALLED IN FIRE SEPARATIONS SHALL BE SEALED WITH DCRA FIRE PROTECTION DIVISION APPROVED FIRE STOPPING METHODS AND MATERIALS. ALL FIRE PROTECTION PIPING INSTALLED SHALL BE TESTED AS REQUIRED BY ALL THE AUTHORITIES HAVING JURISDICTION AND TO THE SATISFACTION OF THE OWNER. ALL FIRE PROTECTION WORK SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM THE DATE OF ACCEPTANCE OF THE FINAL INSTALLATION BY OWNER. ALL AREAS OF THE BUILDING SHALL BE FULLY SPRINKLERED IN ACCORDANCE WITH THE REGULATIONS OF ALL AUTHORITIES HAVING JURISDICTION. THE SPRINKLER SYSTEMS SHALL BE HYDRAULICALLY CALCULATED. THE SPRINKLER CONTRACTOR SHALL VERIFY THE ACTUAL WATER SUPPLY AND PRESSURE AVAILABLE FROM THE WATER SUPPLY SYSTEM BEFORE DESIGN. THE ACTUAL WATER SUPPLY AND PRESSURE SHALL BE VERIFIED BY A FLOW TEST, AS REQUIRED BY DCRA FIRE PROTECTION DIVISION. FIRE SPRINKLER ZONES SHALL BE AS INDICATED ON DRAWINGS. EACH SYSTEM ZONE MUST BE FULLY COORDINATED AS NECESSARY WITH FIRE ALARM CONTRACTOR, SUBMIT SHOP DRAWINGS TO ARCHITECT/ENGINEER AND DCRA FIRE PROTECTION DIVISION FOR REVIEW AND APPROVAL PRIOR TO STARTING WORK. ALL FIRE PROTECTION SHOP DRAWING AND CALCULATIONS SHALL BE STAMPED AND SIGNED BY A REGISTERED PROFESSIONAL ENGINEER. INSTALL SPRINKLER HEADS IN THE CENTER OF CEILING TILE UNLESS NOTED OTHERWISE. ALL FIRE PROTECTION WORK SHALL BE BY AN ACCREDITED FIRE PROTECTION CONTRACTOR REGULARLY ENGAGED IN THE BUSINESS FOR AT LEAST FIVE YEARS AND FAMILIAR WITH THIS WORK AND THE REQUIREMENT OF THE APPROVING JURISDICTION. SPRINKLER SHOP DRAWING SHALL INDICATE PROXIMATE AND SPATIAL RELATIONSHIPS WITH ALL BUILDING CHARACTERISTICS AND COMPONENTS AS REQUIRED TO PRODUCE FULLY COORDINATED DRAWINGS. THE SPRINKLER CONTRACTOR SHALL ALSO REVIEW ARCHITECTURAL REFLECTED CEILING PLANS AS NECESSARY TO COORDINATE WITH SPECIAL ARCHITECTURAL FEATURES AND/OR LIGHTING LAYOUTS IN VARIOUS AREAS. EXTEND SPRINKLER PROTECTION BELOW OPEN STAIRS. HEAD LOCATIONS SHALL BE COORDINATED WITH SLOPED CEILING AND LEVEL CONDITIONS UNDER LANDING IN ACCORDANCE WITH NFPA 13. PROVIDE SPRINKLERS AT TOP OF STAIRWELLS AND UNDER FIRST ACCESSIBLE STAIR LANDING IN ACCORDANCE WITH NFPA 13. 4.1 2014 INDIANA BUILDING CODE, 2015 INDIANA FIRE CODE, 2012 INDIANA PLUMBING CODE, 2009 INDIANA ELECTRIC CODE, 2014 INDIANA MECHANICAL CODE, 2007 ASHRAE 90.1 4.2 NFPA 13, 14, AND 20 (2010 EDITIONS) FIRE PROTECTION HYDRAULIC DATA TYPE OF TYPICAL AREA DESIGNATIONS OCCUPANCY MAXIMUM MIN. HYDRAULIC MIN. HYDRAULIC MAXIMUM REMARKSHAZARD AREA of SYSTEM AREA of APPLICATION DENSITY COVERAGE per DESIGNATION SQ. FT. SQ. FT. GPM / SQ. FT. SQ. FT. DEG. F WET LOBBIES, VESTIBULES, CORRIDORS LIGHT 52000 1500 .10 165 DRY PENDENT WET CLASSROOMS, TOILET RMS. LIGHT 52000 1500 165 SYSTEM SPRINKLER TEMPERATURE RATING of SPRINKLER WET OFFICES, CONFERENCE, TOILET RMS. LIGHT 52000 1500 165 .10 .10 WET MECHANICAL, ELECTRICAL ROOMS ORDINARY 1 52000 1500 .15 130 200 DRY PENDENT DRY PENDENT DRY PENDENT PER LISTING PER LISTING PER LISTING ABOVE CEILING TO WALL AS POSSIBLE MAINTAIN AS TIGHT IN FINISHED SPACES CONNECTION VALVE ROOM OR CHECK VALVE MAIN HEADER IN TO F.D. AUTOMATIC BALL DRIP ESCUTCHEON PLATE CONNECTION WITH EXTERIOR WALL SLEEVE LINK-SEAL FIRE DEPARTMENT GRADE SIDE BEAM BRACKET HANGER PIPE RING FLAT WASHER ALL THREAD ROD SIDE BM BRACKET LAG BOLT & HEX NUT & 3 (HEADER ABOVE GRADE) NTS FIRE DEPARTMENT SIAMESE CONNECTION DETAIL 5 PIPE SUPPORT DETAILS NTS PIPE RING PIPE RING ALL THREAD RODALL THREAD ROD PIPE STAND C-CLAMP WITH LOCKNUT POWDER DRIVEN STUD ROD COUPLING C-CLAMP HANGERPOWDER DRIVEN STUD RISER CLAMP & NUT ASSMB. RISER CLAMPPIPE WET GYMNASIUM, STORAGE, LAUNDRY ORDINARY 1 52000 1500 .15 130 200 DRY PENDENT 4 INCOMING FIRE WATER SERVICE DETAIL NTS NOTES: 1. THE DOMESTIC METER AND FIRE LINE DETECTOR METER WILL BE SUPPLIED AND INSTALLED BY WATER AUTHORITY. 2. INSTALL ALL METERS IN A HORIZONTAL POSITION. (0PTIONAL VERTICAL INSTALLATION REQUIRES BFP'S TO BE USC APPROVED) 3. INSTALL REDUCED PRESSURE ZONE ASSEMBLY ON DOMESTIC POTABLE WATER. DEVICE TO BE AUTHORITY APPROVED. 4. DETECTOR METER AND DOMESTIC METER TO BE INSTALLED WITH ALL BRASS THREADED VALVES AND PIPING AT EACH METER SETTING 5. THE DETECTOR CHECK ASSEMBLIES MUST BE U.L./F/M/ AND USC APPROVED. OPTIONAL VERTICAL INSTALLATION REQUIRES USC APPROVAL. SEE AUTHORITY LIST OF APPROVED MODELS. 6. SEE AUTHORITY FOR METER SETTING DRAWING. 10/29/20