HomeMy WebLinkAboutS-000-GENERAL-NOTES-AND-ABBREVIATIONS. GRAPHIC SYMBOL STRUCTURAL GRAPHIC SYMBOLS SLOPE DIRECTION AXIAL FORCE MEMBER LOAD FLOOR ELEVATION DATUM KEY NOTE EXTERIOR GRADE OR PAVEMENT ELEVATION CONCRETE PATTERN GRADE PATTERN CONSTRUCTION FILL MATERIAL PATTERN KEY JOINT RUBBER OR VINYL WATERSTOP REINFORCING STEEL WELDED WIRE FABRIC -X' - X" OR EMBEDDED ADHESIVE REINFORCING STEEL EMBEDDED ADHESIVE ANCHOR EXPANSION ANCHOR WOOD BLOCK WOOD BLOCK/BEAM END SECTION R=xk 0.0k SLOPE ? DESCRIPTION + STRUCTURAL DETAIL SYMBOLS 1 S101 Ref S000 1 ELEVATION MARKERSECTION MARKER SECTION TITLE Scale: NTS 1 S101 View Name SECTION OR DETAIL IDENTIFICATION NUMBER DRAWING NUMBER WHICH SECTION OR DETAIL IS TAKEN SECTION, DETAIL OR ELEVATION IDENTIFICATION NUMBER DRAWING NUMBER ON WHICH SECTION DETAIL OR ELEVATION IS SHOWN ABBREVIATIONS ABV ACI ADD ADDL ADH ADJ A/E AFF AHU ALT ANCH & ANSI APPD APPROX AR ARCH ASTM @ AVG B/B BC BD BETW BEV BFF BLDG BLK BM BOF BOS BOT BPL BRCG BRDG BRG BRK BRKT BT C CANT C/C CERT CHAM CJ CL CLR CMU COL CONC CONN CONSTR CONSTR JT CONT CONTR CTR DBL DEG DET DIA DIAG DIM DL DN DWG DWGS DWL EA EF EL ELEC EMB ENCL ENG EQ EQPT ES E-W EW EXP JT EXP EXST EXT FD FDN FF FIN FLG FLR FS FT FTG GA GALV GB GC GR GYP H HD HEF HGR HGT HORIZ HP HS HSS HVAC HVY MINUS MATERIAL MAXIMUM MECHANICAL MEMBRANE MEZZANINE MANUFACTURER MINIMUM MISCELLANEOUS MASONRY OPENING METAL NORTH NEAR FACE NOT IN CONTRACT NUMBER NORTH-SOUTH NEARSIDE NOT TO SCALE ON CENTER OUTSIDE DIAMETER OUT TO OUT OPENING OPPOSITE OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION OVERHEAD PER PERCENT PLUS PRECAST CONCRETE PERIMETER PLATE PLYWOOD PANEL PROJECTION POUNDS PER SQUARE FOOT POUNDS PER SQUARE INCH PREFABRICATED PRESSURE TREATED REFERENCE REINFORCEMENT, REINFORCED, REINFORCING REQUIRED RETAINING REVISED/REVISION RIGHT HAND ROUND ROUGH OPENING SCHEDULE SQUARE FEET STEEL FIBER REINFORCED CONCRETE SHEET SHEATHING SIMILAR SLAB ON GRADE SPACE, SPACING SPLICE, SPLICING SPECIFICATIONS STAGGERED STANDARD STIFFENER STEEL STRUCTURAL SUBFLOOR SYMMETRICAL SYSTEM TOP OF TOP AND BOTTOM TOP CHORD TEMPERATURE STEEL THICK, THICKNESS THROUGH TOTAL LOAD TOP OF CONCRETE TOP OF FOOTING TRANSVERSE TOP OF SLAB TYPICAL UNLESS OTHERWISE NOTED VERTICAL EACH FACE VERTICAL WIDTH, WIDE WITH WIND LOAD WITHOUT WEIGHT WELDED WIRE MESH WELDED WIRE REINFORCEMENT ABOVE AMERICAN CONCRETE INSTITUTE ADDENDUM ADDITIONAL ADHESIVE ADJACENT ARCHITECT/ENGINEER ABOVE FINISH FLOOR AIR HANDLING UNIT ALTERNATE, ALTERNATIVE ANCHOR, ANCHORED AND AMERICAN NATIONAL STANDARDS INSTITUTE APPROVED APPROXIMATE ANCHOR ROD, ANCHOR BOLT ARCHITECTURAL, ARCHITECT AMERICAN SOCIETY FOR TESTING AND MATERIALS AT AVERAGE BACK TO BACK BOTTOM CHORD BOARD BETWEEN BEVELLED BELOW FINISHED FLOOR BUILDING BLOCK, BLOCKING BEAM BOTTOM OF FOOTING BOTTOM OF STEEL BOTTOM BASE (BEARING) PLATE BRACING BRIDGING BEARING BRICK BRACKET BOLT CHANNEL CANTILEVER CENTER TO CENTER CERTIFIED CHAMFER CONTROL JOINT, CONTRACTION JOINT CENTER LINE CLEAR, CLEARANCE CONCRETE MASONRY UNIT COLUMN CONCRETE CONNECTION CONSTRUCTION CONSTRUCTION JOINT CONTINUATION (CONTINUOUS) CONTRACT(OR) CENTER DOUBLE DEGREE DETAIL DIAMETER DIAGONAL DIMENSION DEAD LOAD DOWN DRAWING DRAWINGS DOWEL EACH EACH FACE ELEVATION ELECTRICAL EMBEDMENT ENCLOSURE ENGINEER, ENGINEERING EQUAL, EARTHQUAKE EQUIPMENT EACH SIDE EAST-WEST EACH WAY EXPANSION JOINT EXPANSION EXISTING EXTERIOR FLOOR DRAIN FOUNDATION FINISH FLOOR FINISH FLANGE FLOOR FARSIDE FEET FOOTING GAUGE GALVANIZED GRADE BEAM GENERAL CONTRACT , GENERAL CONTRACTOR GRADE GYPSUM HIGH HEAD HORIZONTAL EACH FACE HANGER HEIGHT HORIZONTAL HIGH POINT HIGH STRENGTH HOLLOW STRUCTURAL STEEL HEATING VENTILATING AND AIR CONDITIONING HEAVY - MATL MAX MECH MEMB MEZZ MFR MIN MISC MO MTL N NF NIC NO OR # N-S NS NTS O/C OD O/O OPNG OPP OSHA OVRH / % + PC PERIM PL PLYWD PNL PROJ PSF PSI PREFAB PT REF REINF REQ RET REV RH RND RO SCH SF SFRC SHT SHTHG SIM SOG SP SPL SPECS STAG STD STIFF STL STRU SUB FL SYM SYS T/ T&B TC TEMP STL THK THRU TL TOC TOF TRANS T/SLAB TYP UON VEF VERT W W/ WL W/O WT WWM WWR ID IF IN INCL INFO INSUL INT JST JT K KSF KSI L LB/LBS LEV LF LG LL LLH LLV LONG LP INSIDE DIAMETE0R INSIDE FACE INCHES INCLUDE INFORMATION INSULATION INTERIOR JOIST JOINT KIPS KIPS PER SQUARE FOOT KIPS PER SQUARE INCH LENGTH POUNDS LEVEL PER LINEAR FOOT LONG LIVE LOAD LONG LEG HORIZONTAL LONG LEG VERTICAL LONGITUDINAL LOW POINT is a member of the IBI Group of companies DATE: ISSUE SHEET TITLE PROJECT SCALE: APPROVED BY:PROJECT MGR: PROJECT NO: SHEET NUMBER CLIENT COPYRIGHT ISSUES This drawing has been prepared solely for the intended use, thus any reproduction or distribution for any purpose other than authorized by IBI Group is forbidden. Written dimensions shall have precedence over scaled dimensions. Contractors shall verify and be responsible for all dimensions and conditions on the job, and IBI Group shall be informed of any variations from the dimensions and conditions shown on the drawing. Shop drawings shall be submitted to IBI Group for general conformance before proceeding with fabrication. IBI Group Engineering Services (USA) Inc. CHECKED BY:DRAWN BY: SCALE CHECKSEAL 3221 W Big Beaver, Suite 111 Troy, MI, 48084 10mm1 in CARMEL, IN CONSULTANTS As indicated 0 C:\Users\jon.fairbanks\Documents\REVIT2018\122885_814KC CrmlIN_STRU_v18_jon.fairbanks.rvtGENERAL NOTES AND ABBREVIATIONS 122885 M.STOCK 2020-08-04 S-000 KINDERCARE LEARNING CENTER R.AECK M.MULLEN J.FAIRBANKS 1. THE CONTRACT STRUCTURAL DOCUMENTS REPRESENT THE FINISHED STRUCTURE. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS AND METHODS OF CONSTRUCTION. PROVIDE ALL MEASURES REQUIRED TO PROTECT THE STRUCTURE, WORKMEN AND OTHER PERSONS DURING CONSTRUCTION. PROVIDE ADEQUATE BRACING, SHORING FOR CONSTRUCTION EQUIPMENT AND FOR THE BUILDING, FORMWORK AND SCAFFOLDING, SHEETING AND BRACING OF EXCAVATIONS AND OTHER TEMPORARY SUPPORTS AS REQUIRED. COMPLY WITH APPLICABLE REQUIREMENTS OF THE OSHA CODE, STATE CODES, LOCAL CODES AND OTHER MISCELLANEOUS REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION AT THE SITE. 2. CONSTRUCTION SHALL BE PERFORMED IN A SAFE MANNER BY ERECTING AND MAINTAINING SAFETY BARRICADES EQUAL TO OR EXCEEDING OSHA REQUIREMENTS AND ALL LOCAL CODES AROUND THE CONSTRUCTION AREA AT ALL TIMES. ALL EMPLOYEES SHALL AT ALL TIMES WORK IN COMPLIANCE WITH THE OWNERS SAFETY REGULATIONS. 3. CONTRACTOR TO PERFORM CONSTRUCTION IN A MANNER TO PREVENT DAMAGE TO EXISTING AND NEW STRUCTURES, UTILITIES AND OTHER PROPERTY. REPAIR SURFACES THAT HAVE BEEN DAMAGED. NEW WORK SUCH AS, BUT NOT LIMITED TO PATCHING, PAINTING AND INSULATION SHALL MATCH EXISTING. CONSTRUCTION GENERAL NOTES 4. EXISTING UTILITIES AND ALL OTHER OBSTRUCTIONS TO WORK SHALL BE TEMPORARILY REMOVED BY THE CONTRACTOR AND RE-INSTALLED UNLESS OTHERWISE NOTED, INCLUDING NECESSARY MODIFICATIONS BY THE CONTRACTOR AFTER COMPLETION OF WORK. 5. CONTRACTOR TO PLAN AND SCHEDULE CONSTRUCTION AND DEMOLITION ACTIVITIES TO AVOID INTERFERENCE AND MINIMIZE DISRUPTION OF THE OWNER'S OPERATIONS. 6. CONTRACTOR TO BECOME FAMILIAR WITH THE EXISTING FIELD CONDITIONS AND MAKE NECESSARY FIELD SURVEYS AS REQUIRED FOR PROPER EXECUTION OF THE WORK. BEFORE PROCEEDING WITH THE DETAILING, CAREFULLY EXAMINE AND SURVEY ALL EXISTING STRUCTURES AND CONDITIONS TO VERIFY DIMENSIONS AND SIZES THAT ARE SHOWN ON THE DRAWINGS. REPORT ANY DISCREPANCIES IN THE EXISTING CONDITIONS IMMEDIATELY TO THE OWNER'S REPRESENTATIVE. 7. REFER TO ARCHITECTURAL DRAWINGS FOR DIMENSIONS AND ELEVATIONS NOT SHOWN ON THE STRUCTURAL DRAWINGS. REPORT ANY DISCREPANCIES BETWEEN THE ARCHITECTURAL AND STRUCTURAL DRAWINGS TO THE OWNER'S REPRESENTATIVE PRIOR TO CONSTRUCTION. 8. DETAILS LABELED "TYPICAL DETAILS" ON DRAWINGS APPLY TO SITUATIONS OCCURRING THAT ARE THE SAME OR SIMILAR TO THOSE SPECIFICALLY DETAILED. SUCH DETAILS APPLY WHETHER OR NOT DETAILS ARE REFERENCED AT EACH LOCATION. NOTIFY THE OWNER'S REPRESENTATIVE OF CONFLICTS REGARDING APPLICABILITY OF "TYPICAL DETAILS". 9. PRINCIPAL OPENINGS THROUGH THE FRAMING ARE SHOWN ON DRAWINGS. EXAMINE THE ARCHITECTURAL AND MECHANICAL DRAWINGS FOR THE REQUIRED OPENINGS AND PROVIDE FOR REQUIRED OPENINGS WHETHER SHOWN ON THE STRUCTURAL DRAWINGS OR NOT. VERIFY SIZE AND LOCATION OF OPENINGS WITH THE MECHANICAL CONTRACTOR. DEVIATIONS FROM THE OPENINGS SHOWN ON THE STRUCTURAL DRAWINGS MUST BE APPROVED PRIOR TO IMPLEMENTING CHANGES. 10. DO NOT STORE OR STACK CONSTRUCTION MATERIALS ON ERECTED FLOORS OR ROOFS IN EXCESS OF 80 PERCENT OF SPECIFIED DESIGN LIVE LOAD. MINIMIZE DYNAMIC IMPACT WHEN PLACING MATERIALS ON FLOORS OR ROOFS. 11. THE OWNER WILL RETAIN AN INDEPENDENT TESTING AGENCY TO PROVIDE ALL REQUIRED CONSTRUCTION MATERIAL TESTING, INSPECTION AND OBSERVATIONS. 12. ALL TEST REPORTS SHALL BE RECEIVED WITHIN THREE WORKING DAYS OF THE TEST BEING PERFORMED. TWO COPIES OF THESE REPORTS SHALL BE FORWARDED TO THE OWNER'S REPRESENTATIVE. TEST RESULTS NOT IN CONFORMANCE WITH PROJECT SPECIFICATIONS SHALL BE HIGHLIGHTED. 1. FOR WALLS OR GRADE WALLS HAVING FILL ON EACH SIDE PROCEED WITH BACKFILLING OPERATIONS SIMULTANEOUSLY IN MAX 8" UNIFORM LIFTS DIFFERENTIAL ELEVATION OF TOP OF LIFTS BETWEEN EACH SIDE SHALL NOT EXCEED 18 INCHES. BACKFILLING 2. PLACE BACKFILL ALONG RETAINING WALLS ONLY AFTER THE CONCRETE HAS ATTAINED ITS DESIGN STRENGTH. 1. DESIGN, DETAILING, AND CONSTRUCTION OF REINFORCED CONCRETE SHALL CONFORM TO THE FOLLOWING PUBLICATIONS PER THE IBC UNLESS OTHERWISE NOTED: a. BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE (ACI 318) b. ACI DETAILING MANUAL (ACI SP66) c. SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS (ACI 301) CAST-IN-PLACE CONCRETE 2. CONCRETE SHALL BE NORMAL WEIGHT AND SHALL DEVELOP A MINIMUM COMPRESSIVE STRENGTH OF 4000 PSI AT 28 DAYS UNLESS HIGHER STRENGTH IS NOTED ON THE DRAWINGS. 3. NORMAL WEIGHT CONCRETE USED FOR SPREAD AND STRIP FOOTINGS SHALL DEVELOP A MINIMUM COMPRESSIVE STRENGTH OF 3500 PSI AT 28 DAYS UNLESS OTHERWISE NOTED. 5. PROVIDE ADEQUATE SHEETING, SHORING AND BRACING OF EXCAVATIONS AS REQUIRED FOR SAFE CONSTRUCTION. DESIGN OF TEMPORARY EARTH RETENTION SYSTEMS OR STRUCTURES IS THE RESPONSIBILITY OF THE CONTRACTOR. 6. REINFORCING SHALL BE DEFORMED BARS CONFORMING TO ASTM A615 (GRADE 60) AND SHALL HAVE A MINIMUM YIELD STRENGTH OF 60 KSI. 7. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185 AND SHALL BE FURNISHED IN FLAT SHEETS (NOT ROLLS). 8. WHERE DEVELOPMENT OR SPLICING IS REQUIRED, REINFORCING SHALL HAVE EITHER TENSION EMBEDMENT OR TENSION CLASS "B" LAP SPLICE UNLESS OTHERWISE NOTED. 9. PROVIDE 2-#5 ADDITIONAL BAR PER LAYER OF REINFORCING AROUND OPENINGS LARGER THAN ONE FOOT SQUARE OR DIAMETER UNLESS OTHERWISE NOTED. EXTEND BARS A MINIMUM OF 24 INCHES BEYOND OPENINGS UNLESS OTHERWISE NOTED. PROVIDE 2-#5 x 4'-0" LONG DIAGONAL BARS PER LAYER OF REINFORCEMENT AT ALL RE-ENTRANT CORNERS. 10. PROVIDE HORIZONTAL BENT BARS AT CORNERS AND INTERSECTIONS OF CONCRETE WALLS USING THE SAME SIZE AND SPACING AS FOR HORIZONTAL WALL REINFORCING. USE BENT DOWELS IF NECESSARY TO DEVELOP ANCHORAGE. 11. PROVIDE VERTICAL DOWELS FROM PIER FOOTINGS TO PIERS AND FROM WALL FOUNDATIONS TO WALLS OF SAME SIZE AND SPACING AS VERTICAL REINFORCING AND OFFSET FOR SPLICE AS REQUIRED. 12. CONSTRUCTION JOINTS SHALL HAVE A KEY (OR KEYS) CENTERED ON THE MEMBER. WHERE THE SIZE OF KEY IS NOT SHOWN ON THE DRAWINGS, THE KEY WIDTH SHALL BE ONE FOURTH OF THE CROSS SECTION DIMENSION OF THE MEMBER AND THE KEY DEPTH SHALL BE 10 PERCENT OF THE CROSS SECTION DIMENSION OF THE MEMBER WITH A MINIMUM DIMENSION OF 3/4 INCH. 13. PLACE WALLS, GRADE BEAMS AND STRIP FOOTINGS TO A MAXIMUM LENGTH OF 100 FEET BETWEEN CONSTRUCTION JOINTS. 14. PROVIDE SMOOTH FORMED FINISH ON EXPOSED CONCRETE. 15. PROVIDE 3/4 INCH BY 45 DEGREE BEVELED EDGES ON EXPOSED CORNERS UNLESS OTHERWISE NOTED. 16. FORMS AND REINFORCING STEEL SET IN PLACE MUST BE INSPECTED AND APPROVED BY THE OWNER'S REPRESENTATIVE PRIOR TO PLACING CONCRETE. 17. BEFORE PLACING CONCRETE, REFER TO OTHER TRADE DRAWINGS AND COORDINATE THE LOCATION AND SIZE OF ITEMS SUCH AS, BUT NOT LIMITED TO, OPENINGS, EQUIPMENT PADS, PIPING, CONDUIT, DRAINS, DEPRESSED FLOORS, DOOR HOLD DOWNS IN GRADE WALLS AND EMBEDDED ITEMS. 18. CONSULT WITH THE OWNER'S REPRESENTATIVE FOR APPROVAL OF EXCAVATIONS WHEN CONDITIONS SUCH AS, BUT NOT LIMITED, TO POOR SOIL, WATER, OBSTRUCTIONS, PIPING, AND ADJACENT SEWERS. 19. PROTECT ALL CONSTRUCTION SUCH AS, BUT NOT LIMITED TO, SLABS, GRADE WALLS, OTHER WALLS, AND FOUNDATIONS FROM DAMAGE DUE TO FROST HEAVE. 4. NORMAL WEIGHT CONCRETE USED FOR EXTERIOR SLABS ON GRADE, GRADE WALLS AND EXTERIOR FORMED PIERS SHALL DEVELOP A MINIMUM COMPRESSIVE STRENGTH OF 4500 PSI AT 28 DAYS UNLESS OTHERWISE NOTED. 1. BEAMS AND HEADERS SHALL BE OF HEM-FIR, SPRUCE-PINE-FIR OR DOUGLAS FIR- LARCH NUMBER 2 OR BETTER WITH THE FOLLOWING MINIMUM PROPERTIES: a. Fb = 850 PSI b. Fv = 135 PSI c. Ft = 450 PSI d. Fc = 1,150 PSI e. Fcperp = 405 PSI f. E = 1,300 KSI 2. STUDS AND PLATES SHALL BE OF SPRUCE-PINE-FIR No. 2 OR BETTER WITH THE FOLLOWING MINIMUM PROPERTIES: a. Fb = 675 PSI b. Fv = 135 PSI c. Fc = 725 PSI d. Fcperp = 425 PSI e. E = 1,200 KSI 3. ALL MULTIPLE PLY MEMBERS SHALL BE FASTENED TOGETHER WITH 3 ROWS OF 16d COMMON NAILS AT 12 INCH ON CENTER. DIMENSIONAL LUMBER 4. ALL LUMBER IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESERVATIVE TREATED TO RESIST DECAY. 5. ALL HARDWARE, ANCHORS, ETC FOR USE WITH PRESERVATIVELY TREATED LUMBER SHALL BE HOT-DIPPED GALVANIZED TO G185. ALL HARDWARE, ANCHORS, FASTENERS, ETC IN EXTERIOR APPLICATIONS SHALL BE GALVANIZED TO G90. 6. UNLESS SPECIFICALLY NOTED OTHERWISE FASTENING OF ALL DIMENSIONAL LUMBER SHALL BE PER TABLE 2304.9.1 OF THE SPECIFIED BUILDING CODE. 1. ALL PLYWOOD SHALL BE AMERICAN PLYWOOD ASSOCIATION "CDX" RATED SHEATHING OR BETTER AND SHALL BEAR THE STAMP OF AN APPROVED TESTING AGENCY. 2. LAY UP PLYWOOD WITH FACE GRAIN PERPENDICULAR TO SUPPORTS. ON ROOFS WHERE PLYWOOD IS LAYED UP WITH FACE GRAIN PARALLEL TO SUPPORTS, USE A MINIMUM OF 5-PLY PLYWOOD. STAGGER JOINTS. APA RATED SHEATHING 3. ALL NAILING, COMMON NAILS, WHERE SCREWS ARE INDICATED FOR WOOD TO WOOD ATTACHMENTS USE WOOD SCREWS. 4. ALL PLYWOOD SHALL BE OF THE FOLLOWING NOMINAL THICKNESS, SPAN/INDEX RATIO AND SHALL BE ATTACHED AS FOLLOWS UNLESS NOTED OTHERWISE: SPAN PANEL EDGE PANEL FIELD USE THICKNESS RATIO FASTENER SPACING FASTENER SPACING FLOOR 23/32" T&G 48/24 SCREWS @ 6" OC SCREWS @ 12" OC ROOF 19/32" T&G 40/20 8d NAILS @ 6" OC 8d NAILS @ 12" OC WALL 7/16" 24/16 8d NAILS @ 6" OC 8d NAILS @ 12" OC 5. SCREWS AT FLOOR SHEATHING SHALL BE #8X2 1/2" LONG FOR SHEATHING LESS THAN 1" THICK. 6. ALL FLOOR SHEATHING SHALL BE GLUED TO SUPPORTING MEMBERS WITH APA AFG-01 QUALIFIED GLUE. 7. ALL SHEATHING PANELS FOR WOOD SHEAR WALLS MUST BE A MINIMUM 24" WIDE 1. SLABS ON GRADE SHALL REST ON A MINIMUM OF 6 INCHES OF COMPACTED GRANULAR MATERIAL OVER COMPACTED SUB GRADE. REFER TO PLAN FOR THICKNESS OF SLABS. 2. PROVIDE 2-#5 x 4'-0" LONG DIAGONAL TOP BARS AT ALL RE-ENTRANT CORNERS AROUND GRADE WALLS AND SLAB HOLD DOWNS. 3. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATION AND DETAILS OF SLAB HOLD DOWNS FOR FLOOR FINISHES AND SLOPED FLOOR PROFILES AROUND FLOOR DRAINS, SUMPS, ENTRY DOORS, ETC. SLAB-ON-GROUND 4. REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FOR SIZE AND LOCATION OF UNDER SLAB AND EMBEDDED PIPING, PLUMBING, FLOOR DRAINS, DUCTS, CONDUIT, ETC. 5. DO NOT LOAD SLABS ON GRADE WITH ERECTION CRANES OR ERECTION EQUIPMENT. SLABS HAVE NOT BEEN DESIGNED FOR CRANE LOADS AND WILL REQUIRE TEMPORARY CRIBBING OR OTHER MEANS TO DISTRIBUTE CONCENTRATED LOADS. OBTAIN ENGINEER'S APPROVAL ON PROPOSED CRANE SUPPORT PLAN FOR SLABS PRIOR TO COMMENCING WORK. 1. ALL FOOTINGS SHALL BEAR ON UNDISTURBED VIRGIN SOIL OR ENGINEERED FILL. IF EXISTING FILL MATERIAL IS ENCOUNTERED AT BEARING ELEVATION, REMOVE FILL, TEST SOIL AND REPLACE WITH ENGINEERED FILL OR LEAN CONCRETE TO ACHIEVE REQUIRED BEARING CAPACITY. ENGINEERED FILL SHALL BE PLACED UNDER THE DIRECT SUPERVISION OF GEOTECHNICAL CONSULTANT. TEST BEARING STRATUM PER SPECIFICATIONS. a. SPREAD FOOTINGS SHALL HAVE A MINIMUM NET ALLOWABLE BEARING CAPACITY OF 2.5 KSF. b. CONTINUOUS STRIP FOOTINGS SHALL HAVE A MINIMUM NET ALLOWABLE BEARING CAPACITY OF 2.5 KSF. 2. PROVIDE AS-BUILT DRAWINGS SHOWING ACTUAL BOTTOM ELEVATION OF FOOTINGS AND OTHER APPROVED DEVIATIONS FROM THE DRAWINGS IN ACCORDANCE WITH THE SPECIFICATIONS. 3. REFER TO CIVIL DRAWINGS AND TO SPECIFICATIONS FOR EXCAVATION, BACKFILLING, GRADING AND COMPACTION REQUIREMENTS AND FOR DETAILS OF EXISTING SITE CONDITIONS. SPREAD AND CONTINUOUS FOOTINGS 4. FOUNDATION DESIGN CRITERIA IS BASED ON GEOTECHNICAL ENGINEERING SERVICE REPORT PROJECT # 0016-1263 BY INTERTEK PSI DATED 10/29/2019 5. FROST DEPTH IS 2'-6" BELOW FINISH GRADE. 1. DESIGN, FABRICATION AND ERECTION OF ALL WOOD TRUSSES SHALL BE IN ACCORDANCE WITH LATEST EDITION OF THE FOLLOWING: a. NATIONAL DESIGN SPECIFICATION FOR WOOD STRESS GRADED LUMBER AND ITS FASTENING. b. TRUSS PLATE INSTITUTE PUBLICATION, DESIGN SPECIFICATIONS FOR LIGHT METAL CONNECTED WOOD TRUSSES. c. TRUSS PLATE INSTITUTE PUBLICATION, BTW BRACING WOOD TRUSSES COMMENTARY AND RECOMMENDATIONS. 2. TRUSS MATERIAL SHALL BE SOUTHERN YELLOW PINE OF SIZE AND GRADE DETERMINED BY THE TRUSS MANUFACTURER. MINIMUM GRADE SHALL BE NUMBER 2. WOOD TRUSSES 3. WEB MEMBER CONFIGURATIONS FOR EACH PARTICULAR TRUSS SHALL BE DETERMINED BY THE TRUSS MANUFACTURER AND SUBMITTED TO THE ENGINEER OF RECORD FOR REVIEW AND COMMENT. 4. EACH TRUSS SHALL BE DESIGNED TO ACT AS PART OF A ROOF FRAMING SYSTEM. THE DESIGN OF ANY TEMPORARY OR PERMANENT BRACING REQUIRED FOR STABILITY OF THE TRUSS SYSTEM SHALL BE THE RESPONSIBILITY OF THE TRUSS MANUFACTURER. 5. ALL TRUSS CONNECTIONS SHALL BE DESIGNED BY THE TRUSS MANUFACTURER TO SUPPORT THE DESIGN LOADS SPECIFIED IN THE DESIGN CRITERIA PER THE LATEST TRUSS PLATE INSTITUTE STANDARD. PROVIDE MINIMUM 20 GAGE G60 GALVANIZED SHEET STEEL CONNECTION PLATES CONFORMING TO ASTM A 653, GRADE 33. 6. WHEN TRUSSES ARE REQUIRED TO FRAME INTO OTHER TRUSSES (ie. JACK TRUSSES INTO A GIRDER TRUSS), THE CONNECTION AND HANGER DESIGN SHALL BE THE RESPONSIBILITY OF THE TRUSS MANUFACTURER. THE TRUSS MANUFACTURER SHALL MAKE THE NECESSARY PROVISIONS IN THE SUPPORTING TRUSS TO ACCEPT ANY NECESSARY HARDWARE OR HANGERS FOR THE SUPPORTED TRUSS. 7. ALL MULTIPLE PLY TRUSSES SHALL BE FASTENED TOGETHER USING 16d COMMON NAILS AT 8" ON CENTER. 8. SUBMITTALS FOR WOOD TRUSSES SHALL INCLUDE: a. IN GENERAL WOOD TRUSS SUBMITTALS SHALL CONFORM TO SECTION 2303.4.1 OF THE SPECIFIED BUILDING CODE. b. DIAGRAM AND DESIGN INFORMATION FOR EACH UNIQUE TRUSS BEING SUPPLIED. c. LAYOUT DRAWING INCLUDING THE LOCATION OF EACH SPECIFIC TRUSS. d. HANGER TYPE AND INFORMATION FOR EACH TRUSS TO TRUSS CONNECTION. e. ERECTION DRAWINGS INCLUDING THE LOCATION OF ALL PERMANENT BRACING OF THE TRUSS FRAMING SYSTEM. (FOR RECORD PURPOSES ONLY) 9. THE TRUSS DESIGN SHALL CONSIDER ALL APPLICABLE LOADING COMBINATIONS AS LISTED IN SPECIFIED BUILDING CODE. 10. LOADING FOR TRUSS DESIGN AND SUPPORT REACTIONS: a. TOP CHORD LIVE LOAD = 20.0 psf b. TOP CHORD SNOW LOAD = SEE SNOW DESIGN CRITERIA c. TOP CHORD DEAD LOAD = 6.0 psf d. BOTTOM CHORD DEAD LOAD = 11.0 psf e. REFER TO DIAGRAM ON SHEET S-001 FOR UNBALANCED SNOW LOAD 11. THE TRUSS SYSTEM DESIGN AND SUPPORT REACTIONS SHALL CONSIDER THE EFFECTS OF WIND UPLIFT PRESSURES AS INDICATED. 1. CONTRACTOR SHALL FURNISH, ERECT, AND REMOVE AS NOTED ALL ELEMENTS OF THE TEMPORARY EARTH RETENTION SYSTEM NECESSARY TO SAFELY MAINTAIN THE REQUIRED OPEN-CUT EXCAVATION DURING THE CONSTRUCTION OF ALL BELOW GROUND WORK. ACTUAL SIZE AND LOCATION OF ALL ELEMENTS OF SYSTEM SHALL BE DETERMINED BY CONTRACTOR AND INDICATED ON SHOP DRAWINGS. CONTRACTOR DESIGN SHALL BE PERFORMED UNDER THE DIRECTION OF, AND SEALED BY, A LICENSED PROFESSIONAL ENGINEER EXPERIENCED IN THIS TYPE OF WORK. SHOP DRAWINGS, INCLUDING DETAILED SEQUENCE OF WORK, SHALL BE SUBMITTED TO ARCHITECT-ENGINEER FOR REVIEW PRIOR TO COMMENCEMENT OF ANY WORK. TEMPORARY EARTH RETENTION SYSTEM 2. VERIFY LOCATION OF ALL UNDERGROUND UTILITIES. ELEMENTS OF RETENTION WALL SHALL BE DESIGNED, INSTALLED, AND REMOVED SO AS TO AVOID DAMAGE TO ANY EXISTING UTILITIES. CONTRACTOR SHALL PROVIDE TEMPORARY SUPPORT AND/OR PROTECTION OF EXISTING UTILITIES WITHIN OR ADJACENT TO EXCAVATED AREA DURING CONSTRUCTION PERIOD. 3. PROVIDE SUFFICIENT CLEARANCE AROUND RETENTION SYSTEM TO ALLOW COMPLETION OF ALL WORK WITHIN EXCAVATION WITHOUT INTERFERENCE FROM ELEMENTS OF RETENTION SYSTEM. 4. PROVIDE TIEBACKS AND WALES, AS REQUIRED, OF SUFFICIENT SIZE AND SPACING TO RESIST ALL LOADS. 1. PROVIDE DETAILING, FABRICATION, AND INSTALLATION OF REINFORCING AND ACCESSORIES IN ACCORDANCE WITH ACI 315 AND ACI 318. 2. PROVIDE NEW BILLET STEEL REINFORCING BARS IN ACCORDANCE WITH ASTM A615, GRADE 60. 3. COORDINATE PLACEMENT OF CAST-IN-PLACE EMBEDS AND ANCHOR RODS. SET ANCHOR RODS WITH A TEMPLATE. SECURELY ATTACH EMBED ITEMS TO FORMWORK OR REINFORCING. REINFORCING STEEL 4. PROVIDE CLASS "B" REINFORCEMENT SPLICES FOR CONTINUOUS REINFORCEMENT. PROVIDE STANDARD 90-DEGREE HOOKS IN ACCORDANCE WITH ACI 318, UNLESS NOTED OTHERWISE. 5. MAINTAIN THE FOLLOWING CONCRETE COVERAGE FOR REINFORCING STEEL UNLESS NOTED OTHERWISE. a. CONCRETE CAST AGAINST EARTH: 3 INCHES b. CONCRETE EXPOSED TO WEATHER i. NUMBER 6 AND LARGER: 2 INCHES ii. NUMBER 5 AND SMALLER: 1 1/2 INCHES c. CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH THE GROUND: i. SLABS AND WALLS 1. NUMBER 14 AND NUMBER 18: 1 1/2 INCHES 2. NUMBER 11 AND SMALLER: 3/4 INCHES 6. DO NOT WELD OR BEND REINFORCEMENT IN THE FIELD UNLESS SPECIFICALLY SHOWN OR APPROVED BY THE STRUCTURAL ENGINEER. 7. WHEN SPECIFICALLY APPROVED, PROVIDE WELDED REINFORCEMENT ACCORDANCE WITH ASTM A 706 GRADE 60. USE LOW HYDROGEN ELECTRODES FOR WELDING OF REINFORCEMENT IN CONFORMANCE WITH "RECOMMENDED PRACTICES FOR WELDING REINFORCING STEEL, AMERICAN WELDING SOCIETY, AWS D12.1. PROVIDE ASTM GRADE 40 REINFORCING BARS WHERE DETAILED BARS ARE TO BE WELDED TO A STEEL SECTION. 8. WHERE REQUIRED, PROVIDE DOWELS TO MATCH SIZE AND SPACING OF MAIN REINFORCING. 9. PROVIDE CONTINUOUS HORIZONTAL WALL REINFORCEMENT WITH 90-DEGREE BENDS AND EXTENSIONS AT CORNERS AND INTERSECTIONS AS SHOWN ON TYPICAL BAR PLACING DETAILS. 10. WHEN SHOWN ON DRAWINGS PROVIDE FIBER REINFORCING IN ACCORDANCE WITH SPECIFICATIONS. ADD FIBER REINFORCING TO THE CONCRETE MIX IN ACCORDANCE WITH ASTM C 1116 AND THE MANUFACTURERS RECOMMENDATIONS. 11. REFER TO S-200 FOR CONCRETE REINFORCING TENSION LAP SPLICE AND DEVELOPMENT LENGTH SCHEDULE 1. LAMINATED VENEER LUMBER (LVL) MEMBERS SHALL CONFORM TO THE FOLLOWING MINIMUM PROPERTIES: a. Fb = 2600 PSI b. Fv = 285 PSI c. Ft = 1555 PSI d. Fcperp = 750 PSI e. Fcpar = 2510 PSI f. E = 1,900,000 PSI 2. ALL MULTIPLE PLY MEMBERS SHALL BE FASTENED TOGETHER IN ACCORDANCE WITH THE FOLLOWING FASTENER PATTERN: a. UP TO 3 - PLY'S OF 1 3/4" WIDE MEMBERS USE 2 - ROWS OF 10d NAILS @ 12" OC, EACH FACE b. 4 - PLY 1 3/4" WIDE MEMBERS, USE 2 - ROWS OF SIMPSON STRONG TIE 6" LONG SDS SCREWS @ 16" OC, EACH FACE. STANDARD WOOD SCREWS ARE NOT TO BE USED IN LIEU OF SDS SCREWS. c. THE ABOVE FASTENER SIZE AND SPACINGS ARE MINIMUMS. IN ALL CASES, REFER TO MANUFACTURER'S PRODUCT MANUAL AND SPECIFICATIONS TO DETERMINE FASTENER SIZE AND SPACING. 3. DO NOT CUT CUT OR DRILL LVL MEMBERS, EXCEPT AS DIRECTED BY THE LVL MANUFACTURER. CONTRACTOR TO REVIEW MANUFACTURER'S PRODUCT MANUAL AND BECOME FAMILIAR WITH ALL CONSTRUCTION DETAILS AND TABLES. 4. DO NOT PLACE ENGINEERED LUMBER DIRECTLY IN CONTACT WITH CONCRETE OR MASONRY, UNLESS USING PRESERVATIVELY TREATED LUMBER TO RESIST DECAY. 5. FOR ANY TYPICAL FASTENING AND DETAILS NOT SHOWN IN THE DRAWINGS, CONSULT WITH MANUFACTURER'S PRODUCT MANUAL. ENGINEERED WOOD 1. DESIGN, DETAILING, FABRICATION AND ERECTION OF STRUCTURAL STEEL SHALL CONFORM TO THE LATEST EDITION OF THE FOLLOWING PUBLICATIONS EXCEPT AS SPECIFICALLY INDICATED IN THE CONTRACT DOCUMENTS: a. AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) STEEL CONSTRUCTION MANUAL b. AISC SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS (ANSI/AISC 360) c. SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS BY RESEARCH COUNCIL ON STRUCTURAL CONNECTIONS (RCSC) d. AMERICAN WELDING SOCIETY (AWS) STRUCTURAL WELDING CODE D1.1 STRUCTURAL STEEL 3. MAKE FIELD CONNECTIONS WITH ASTM A325-N TYPE 1 HIGH STRENGTH BEARING TYPE BOLTS (THREADS ASSUMED IN THE SHEAR PLANE) UNLESS OTHERWISE NOTED. 4. FOR STEEL TO WOOD CONNECTIONS, PROVIDE SNUG TIGHTENED BOLTS FOR ALL CONNECTIONS, WITH ANCO LOCKING NUTS OR APPROVED EQUAL. 2. MATERIALS SHALL CONFORM TO THE FOLLOWING SPECIFICATIONS UON: a. ALL OTHER STRUCTURAL SHAPES (L, C, S, M & PLATE).... ASTM A36 5. PERFORM ALL WELDING BY ELECTRIC ARC METHOD IN ACCORDANCE WITH THE AWS STRUCTURAL WELDING CODE D1.1. WELDING ELECTRODE SHALL BE LOW HYDROGEN E70XX. 6. FOR THE EXTERIOR STEEL PRIMER, CONTRACTOR TO PROVIDE AN EXTERIOR ALKYD OR LATEX BASED RUST INHIBITING PRIMER RECOMMENDED BY THE MANUFACTURER OF THE FINISH COAT, FOR THE STEEL SUBSTRATE. 7. FOR EXTERIOR STEEL, CONTRACTOR TO PROVIDE A FINISH COAT USING A ZINC RICH PAINT. SEE BELOW FOR A LIST OF APPROVED MANUFACTURER'S AND PAINT TYPES: a. BENJAMIN MOORE; ULTRA SPEC EXTERIOR b . GLIDDEN PROFESSIONAL; FORTIS 350 EXTERIOR c. INTERNATIONAL PAINT / DEVOE COATINGS; DEVCRYL d. SHERWIN WILLIAMS; A-100 No. DESCRIPTION DATE 0 PERMIT 2020-08-04 2020-08-04 10/29/20