Loading...
HomeMy WebLinkAboutAE0-001-GEN-NOTES,-ABBREVWOOD BLOCKING WOOD (FINISH) PLYWOOD EARTH CONCRETE MORTAR / GROUT / PLASTER / GYP BD CMU (CUT) BRICK (CUT) STEEL (CUT) INSULATION (RIGID) INSULATION (LOOSE OR BATT) is a member of the IBI Group of companies DATE: ISSUE SHEET TITLE PROJECT SCALE: APPROVED BY:PROJECT MGR: PROJECT NO: SHEET NUMBER CLIENT COPYRIGHT ISSUES This drawing has been prepared solely for the intended use, thus any reproduction or distribution for any purpose other than authorized by IBI Group is forbidden. Written dimensions shall have precedence over scaled dimensions. Contractors shall verify and be responsible for all dimensions and conditions on the job, and IBI Group shall be informed of any variations from the dimensions and conditions shown on the drawing. Shop drawings shall be submitted to IBI Group for general conformance before proceeding with fabrication. IBI Group Engineering Services (USA) Inc. CHECKED BY:DRAWN BY:SCALE CHECKSEAL 3221 W Big Beaver, Suite 111 Troy, MI, 48084 10mm1 in CONSULTANTS 12" = 1'-0" 0 C:\Users\heather.gulla\Documents\REVIT2018\122885_814KC CrmlIN_arch_v18_roofedit_heather.gulla.rvtGEN NOTES, ABBREV 122885 M.STOCK 2020-02-19 AE0-001 KINDERCARE LEARNING CENTER L.SMIGLIANI CARMEL, IN C.GREER E.SHELINE SOAP DISPENSER, SMOKE DETECTOR, SUPPLY DIFFUSER SPACES OR SPARK PROOF FLOOR FINISH STRUCTURAL STEEL OR SERVICE SINK TOP CHORD OR TOP OF CURB ELEVATION WORKING POINT OR WEATHER PROOF DRAWING NUMBER ON WHICH SECTION OR DETAIL IS DRAWN TITLE WHERE SECTION IS DRAWN ELEVATION SYMBOL SYMBOL WHERE SECTION IS TAKEN DETAIL SYMBOLS MH MANHOLE OR MOUNTING HEIGHT SPR SINGLE-PLY ROOF CORR CORRIDOR CUBIC YARD CABINET UNIT HEATER CARPET CARPET TILE CONTROLLED ROOF DRAIN CARBON STEEL COUNTERSINK CERAMIC TILE CENTER DOUBLE DEPARTMENT DETAIL DRINKING FOUNTAIN DOOR HEADER DIAMETER DIAGRAM DIFFUSER OR DIFFERENCE DIMENSION DISPENSER DOOR JAMB DOWN DOOR OPENING DAMPPROOFING DAMPER DOOR DRAIN DOWNSPOUT DOOR SWITCH DRAWING DOMESTIC WATER HEATER DIA DP DPR DR DR DS DSW DWG DWH DIAG DIFF DIM DJ DN DO DISP CY CUH DBL DET DF DH DEPT CPT CPTT CRD CS CSK CT CTR CB CATCH BASIN CEMENT CENTER TO CENTER CERTIFIED CUBIC FEET CUBIC FEET PER MINUTE CHALK BOARD CHECKERED PLATE CAST IRON CONSTRUCTION JOINT CEILING CONTROL JOINT CAULKING CLOSET CLEAR CLOSURE CENTIMETER CERAMIC MOSAIC TILE CONCRETE MASONRY UNIT CLEANOUT COLUMN CONFERENCE CONNECTION CONSTRUCTION CONTINUOUS OR CONTINUATION CONTRACT(OR) CONVECTOR CORRUGATED CONCRETE CENTERLINE CHEMICAL CONC CONSTR CONTR CONF CONN CONV CORG CONT CLR CLS CM CMU CO COL CMT CHKD PL CI CJ CL CLG CLJ CLKG CLO CEM C/C CERT CFM CHBD CHEM CF BEAM BACK TO BACK BULLETIN BOARD BOTTOM CHORD OR BACK OF CURB BOARD BETWEEN BEVEL BELOW FINISH FLOOR BELOW HUNG CEILING BITUMINOUS BUILDING BLOCKING BOTTOM OF FOOTING BOTTOM OF STEEL BOTTOM BRACING BEARING BRICK BRACKET BOTH SIDES BIRD SCREEN BASEMENT BRITISH THERMAL UNIT BRITISH THERMAL UNIT PER HOUR BULLETIN BUILT-UP ROOFING COURSE OR COVE BLOCK CONTROLLED ACCESS SYSTEM CABINET BOT BTU BULL BUR C BTUH CAS CAB BRG BRK BRKT BS BSC BSMT BRCG BHC BM BITUM BLDG BLK BOF BOS BLKG B/B BBD BC BET BEV BFF BD EXPLOSION PROOFXP RECEPTACLE PANEL RIGHT OF WAY ROOFING ROOM OR RECESSED MAT RAILROAD RIGHT HAND ROUGH OPENING ROOF HOSE HOUSE RAISED FACE OR RETURN FAN REGISTER RETURN AIR REGISTER RETURN AIR GRILLE PARTITION REQUIRED PAPER TOWEL RECEPTACLE PAVEMENT PAPER TOWEL DISPENSER/RECEPTACLE QUARRY TILE RISER, RESINOUS FLOORING OR RADIUS RECEPTACLE RESILIENT (SHEET RUBBER) REMOVABLE REINFORCED (REINFORCEMENT) REFERENCE RAISED ACCESS FLOOR ROOF CONDUCTOR RUBBER TILE ROOF DRAIN OR ROAD RETURN AIR LBS POUNDS LOCKWASHER LCKW RP RR INSTRUMENTATION AND CONTROLS INSULATED ACOUSTICAL METAL SIDING HEATING, VENTILATING & AIR CONDITIONING HEATING AND VENTILATING UNIT INCORPORATED OR INCANDESCENT INSUL INSULATION POUND LAMINATE LABORATORY LENGTH OR LONG LAVATORY INVERT INTERIOR JUNCTION BOX JANITOR CLOSET KITCHEN KICK PLATE KIT L LAM LAV LB LAB KPL INV INTR JB JC K JT KIPS JOINT HYDRANT INCLUDE INCH(ES) INSIDE DIAMETER INVERT ELEVATION INSULATED METAL PANEL INSULATED METAL SIDING INFORMATION HOT WATER HEATER ID INCL IE IMP IN INC INFO IMS HYD I&C IAMS HVAC HVU HWH RC RES ROW RFG RM RO RHH RH RF REG REINF REF RECPT REQD REMV RD RAR RAG R RAF RBT RA PWR PTN PVMT PTR QT PTD/R POWER YD YARD W/O WMP WO WSCT WS WP WWF WT WOM WF WC WGL WDW WD WJ WH VIN VOL VT VWC W/ W VTR VAV VERT VCT VAC VEST VENT V WITHOUT WASH FOUNTAIN WATER CLOSET WINDOW HEAD OR WATER HEATER WOOD OR WIDE WINDOW SILL OR WATERSTOP WOMEN'S TOILET OR WEIGHT WINDOW OPENING WIRE MESH PARTITION WELDED WIRE FABRIC WAINSCOT WOMEN'S WIRE GLASS WINDOW WINDOW JAMB VARIABLE AIR VOLUME VINYL COMPOSITION TILE VINYL WALL COVERING VENT THRU ROOF WEST OR WIDTH VINYL VOLUME VINYL TILE WITH VESTIBULE VERTICAL VACUUM VENTILATOR VENT OR PERSONAL COMPUTER NATIONAL ELECTRIC CODE MOLDING NOMINAL OBSCURE OPENING OPPOSITE POST INDICATOR VALVE PLATFORM PLYWOOD MICROPHONE MISCELLANEOUS MILLIMETER MOVABLE METAL PARTITION MASONRY OPENING MOVABLE PARTITION METAL SHAKE MEN'S TOILET MOUNTED MOUNTING NOT IN CONTRACT NON-SLIP OR NEAR SIDE NOT TO SCALE ON CENTER OUTSIDE DIAMETER OVERHEAD DOOR OPERATOR PLASTIC LAMINATE PERFORATED PENETRATION PUSH BUTTON STATION PANIC BAR PIECE, PROTECTIVE COATING POWER PANEL MISCELLANEOUS IRON OUT TO OUT PORCELAIN PROPERTY PROJECT OR PROJECTION POINT OR PORCELAIN TILE POUNDS PER SQUARE FOOT PREFABRICATED PAPER TOWEL DISPENSER POUNDS PER SQUARE INCH OHDR GLAZE (GLAZING) G HIGH POINT OR HORSEPOWER GYPSUM WALL BOARD (DRYWALL) HIGH H HIGH VOLTAGE HEAD OR HEAVY DUTY HOSE BIBB HOLLOW CORE HANDICAPPED HARDWARE HEXAGON HANGER HEIGHT HOLLOW METAL HORIZONTAL HANDRAIL HIGH STRENGTH HEATER HGT HV HM HP HORIZ HR HS HTR HB HC HCP HDWE HEX HGR HD GLASS GAGE (GAUGE) GALVANIZED GRAB BAR GENERAL CONTRACT(OR) GENERATOR GENERAL GALVANIZED IRON GYPSUM GYPSUM LATH GYPSUM TILE GRATING GRADE OR GRILLE GL GP GR GPB GPL GPT GRT GA GB GC GEN GALV GI GENL PL PLATE PROP PROJ PREFAB PTD PSI PT PSF PR PAIR PLAM PLAS PLTF PLYWD PP PNL PORC PLASTER PANEL PB PH PC PBS PERF PEN PIV PHASE OPER OPNG O/O OZ OPP P OUNCE PAINT FOF FACE OF FINISH FACE OF MASONRY FACE OF STUDS FOLDING PARTITION FEET PER MINUTE FIREPROOF FRAME FRAMING FIBER REINFORCED PLASTIC FOOTING FURRING FUTURE FABRIC WALL COVERING FABRIC WRAPPED PANELS FT FRP FTG FURR FUT FWC FWP FEET FP FOM FOS FR FPM FPRF FRMG FIRE EXTINGUISHER CABINET FINISH FLOOR FOUNDATION FIRE EXTINGUISHER FACE TO FACE FACTORY FINISH FIRE HOSE CABINET FIRE HOSE RACK/REEL FLAT HEAD WOOD SCREW FLASHING FLUORESCENT FLEXIBLE FACE OF CONCRETE FIXTURE FHWS FIN FL FIXT FLUOR FLX FOC FLASH FEC FE FDN FFIN FHC FHR F/F MTD NOM NOS NS OBS OC OD OFF NTS NOSING OFFICE NEC MTG MUL N NIC NO MULLION NORTH NUMBER MMP MO MOD MRBL MS MT MP MODULE MARBLE MIC MI MIR MISC MLDG MM MIN MIRROR MINIMUM TUBULARTBLR TP UG UH UON UNF UMS UR UL TW TR TRD TPD TYP TV UC TOF THD TH THK TOS TKBD THRES TC TEL TEMP TE TERM TER TD TOILET PARTITION TOP OF WALL ELEVATION TOILET PAPER DISPENSER UNDERGROUND UNLESS OTHERWISE NOTED UNINSULATED METAL SIDING UNDERWRITERS LABORATORY TREAD (NOTES) UNIT HEATER URINAL UNFINISHED TRAP ROCK TYPICAL TELEVISION UNDERCUT TEMPERED OR TEMPERATURE TOP OF FOOTING TOP ELEVATION TOP OF STEEL TRENCH DRAIN TOWEL HOOK THREAD THICK TACKBOARD THRESHOLD TERRAZZO TERMINAL TELEPHONE T & G T & B TBD SYS SYM T TB STOR SURF SUSP SV SWBD SWP SUBST STRU SST ST STA STIFF STD STN STL STAGG SSC SQ YD SR SQ FT SQ SSM SS TO BE DETERMINED SHEET VINYL OR SMOKE VENT TONGUE AND GROOVE TREAD OR THERMOSTAT TOP AND BOTTOM STRETCH WALL PANEL SYSTEM SYMMETRICAL TOWEL BAR STRUCTURAL STORAGE SURFACE SUSPENDED SWITCHBOARD SUBSTATION STRUCTURAL STEEL CONTRACT SHEET ROLLED RESILIENT STAINLESS STEEL SOLID SURFACE MATERIAL STAIN (WOOD) STATION STEEL STIFFENER STANDARD STONE STAGGERED SQUARE YARD SQUARE FOOT SQUARE MATERIAL INDICATIONS ADD ADDENDUM AIR HANDLING UNIT ADHESIVE ADJACENT ADJUSTABLE ADMINISTRATIVE ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AGGREGATE AUTOMATIC GUIDED VEHICLE ABOVE HUNG CEILING ALUMINUM ACTIVE LEAF ALUMINUM THRESHOLD ALTERNATE ACOUSTICAL METAL PANEL ANCHOR ACID PROOF FINISH ACCESS PANEL APPROXIMATE ARCHITECTURAL AUTOMATIC SPRINKLERS ASPHALT AUTOMATIC SPRINKLER RISER ASSOCIATION / ASSOCIATES ASSEMBLY ASTRAGAL ATHLETIC FLOORING AVERAGE ACOUSTIC WALL COVERING AMP ASR ASSOC ASSY ASTR ATH AWC AVG APPROX AP APNL AS ASPH ARCH ANC AHU AHC AL ALF AGV AL/T ALT ADH ADJ ADJT ADMIN AFF AFG AGGR ANCHOR BOLT ABOVE BOTTOM CHORD ABRASIVE ABOVE ACCESS ACOUSTICAL ACOUSTICAL CEILING TILE AB ABC ABR ACC ACST ACT ABV OR LOUVER HEAD MANUFACTURER LIGHTING MACHINE MATERIAL ABBREVIATIONS LIQUID HARDENER OR LEFT HAND LOUVER JAMB LONG LEG HORIZONTAL LONG LEG VERTICAL LOUVER OPENING LOCATION (LOCATE) LOW POINT OR LIGHTING PANEL MASONRY MAXIMUM MEDICINE CABINET MOTOR CONTROL CENTER MAIN CONTROL PANEL MECHANICAL MEMBRANE METAL EDGE STRIP LOUVER SILL METAL DIVIDER STRIP MAKE UP AIR UNIT MANUFACTURING METAL FRAME WITH GLASS METAL GRATE MANAGER MEZZANINE LLH EC EXPOSED CONSTRUCTION EXHAUST FAN OR EACH FACE EMERGENCY SHOWER AND EYE WASH ESW ELECTRIC WATER HEATER EACH WAY ELECTRIC WATER COOLER EXCAVATED EXHAUST EXPANSION EXPOSED EXISTING EXTERIOR FAHRENHEIT FABRIC FLOOR CLEAN OUT ELECTRIC UNIT HEATER FLOOR DRAIN EXPO EXST EXT F FB FCO FD EWH EW EUH EXCV EXH EXP EWC EQUAL EXPANSION JOINT ELEVATION ELECTRICAL OR ELECTRIC ELEVATOR EMERGENCY EMERGENCY SHOWER EMERGENCY EYE WASH ENCLOSURE EPOXY EQUIPMENT ELECTRIC OPERATED EMERY SHAKE EO EW ENCL EQ EPX EQPT ES EF EJ EL ELEC ELEV EMER EMS MES MFR MET MFG MG MF/GL MGR MEZZ METAL MC MCC MCP MECH MED MDS MEMB MEDIUM LVR LTG MACH MAS MATL MAX MAU M LOUVER METER LLV LNDG LO LOC LP LT LS LIGHT LANDING DOWELS DRAWER DWL DWR E EA EAST EACH LKR LIN LG LH LJ LEV LOCKER LINEAR LONG LEVEL ROOF VENTRV SF SPEC SNR SND SLV SO SPKR SP SH SHR SHLD SLTD SIM SHTG SHT SC SCH SCD SECY SD SECT SCR SEP RVC SAR SAN SAG S SA SUPPLY FAN SASH OPENING SANITARY NAPKIN RECEPTACLE SANITARY NAPKIN DISPENSER SPECIFICATION SLEEVE SPEAKER SHELF SIMILAR SLOTTED SHEATHING SHEET SHOWER SHIELDED ROLLING VINYL CURTAIN SUPPLY AIR REGISTER SANITARY SEWER SUPPLY AIR GRILLE SOUTH OR SEALER SUPPLY AIR OR SOUND ABSORBING SEAT COVER DISPENSER SOLID CORE SECRETARY SECTION SCHEDULE SCREW SEPARATE RTU RS RSC RST RSR RTN RSB A-35 35C ROOFTOP UNIT RESILIENT TILE ROLLING STEEL CURTAIN ROLLED SHEET RESILIENT RESILIENT BASE ROOF SUMP RETURN DRAWING ON WHICH ELEVATION IS DRAWN ELEVATION NUMBER IS IDENTIFIED SECTION OR DRAWING NUMBER ON WHICH SECTION OR DETAIL AREA DETAIL IDENTIFICATION NUMBER A-4 4C SECTION OR DETAIL IDENTIFICATION NUMBER A-5 5B GENERAL NOTES A-35 35C DETAIL TITLE 3/4 "=1'-0" A-5 5B HAND DRYER HDRY WR WASTE RECEPTACLE CONSTRUCTION SITE NOTES GENERAL COORDINATION NOTES 1. CONFORM TO ALL OWNER'S GENERAL AND SPECIAL CONDITIONS IN THE PERFORMANCE OF THE WORK OR AS HEREIN SPECIFIED. 2. ALL WORK IS TO BE PERFORMED IN ACCORDANCE WITH THE APPLICABLE BUILDING CODE AND ALL APPLICABLE STATE AND LOCAL CODES, ACCESSI BILITY STANDARDS AS WELL AS ANY APPLICABLE OWNER'S CORPORATE STANDARDS. THE LOCAL CODE AUTHORITY HAS THE AUTHORITY TO INTERPRET CODE REQUIREMENTS AND THESE INTERPRETATIONS MAY VARY FROM NORMAL INTERPRETATION AND INFORMATION REPRESENTED IN THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL INFORM THE OWNER'S REPRESENTATIVE OR THE ARCHITECT-ENGINEER OF ANY DISCREPANCIES OR DIFFERENCES AND SHALL PROCEED WITH THE WORK ONLY UPON RECEIVING WRITTEN AUTHORIZATION. 3. THE DRAWINGS SHALL NOT BE USED FOR CONSTRUCTION PURPOSES UNTIL THE SEAL AND SIGNATURE OF THE RESPONSIBLE REGISTRANT APPEARS O N THE DRAWING, AND PROPER PERMIT FORMS AND RELATED FEES ARE TRANSMITTED BY THE OWNER, OWNER'S AGENT, OR CONTRACTOR TO THE AUTHORITY HAVING JURISDICTION. 4. CONTRACTOR TO OBTAIN ALL REQUIRED CONSTRUCTION PERMIT FORMS, PAY ALL RELATED FEES, AND ARRANGE FOR ALL REQUIRED INSPECTIONS AND APPROVALS. 5. BIDDER/CONTRACTOR SHALL VISIT THE SITE, EXAMINE AND VERIFY EXISTING CONDITIONS UNDER WHICH THE WORK SHALL BE CONDUCTED AND AC COUNT FOR EXISTING FIELD CONDITIONS AND ACTUAL FIELD DIMENSIONS IN ALL BIDS SUBMITTED AND ALL WORK PERFORMED. REPORT ANY DISCREPANCIES IN THE EXISTING CONDITIONS IMMEDIATELY TO THE OWNER'S REPRESENTATIVE OR ARCHITECT/ ENGINEER. 6. CONTRACTOR SHALL REVIEW ALL CONTRACT DOCUMENTS, INCLUDING SPECIFICATIONS, OF INTERFACING TRADES AND OTHER RELATED CONTRACTS PRIOR TO BIDDING AND COMMENCEMENT OF WORK TO ENSURE COMPLETE COORDINATION OF FINISHED WORK. 7. EACH SUBCONTRACTOR IS RESPONSIBLE TO COORDINATE AND SCHEDULE THEIR WORK WITH THE GENERAL CONTRACTOR AND ALL OTHER CONTRACTORS WHO'S WORK WILL BE AFFECTED. SPECIFICATIONS ARE APPLICABLE AND BINDING TO ALL CONTRACTORS AND SUBCONTRACTORS. REPORT ALL DISCREPANCIES, PRIOR TO CONSTRUCTION, TO THE OWNER'S REPRESENTATIVE OR ARCHITECT/ ENGINEER FOR REVIEW AND CLARIFICATION. 8. BEFORE AWARD OF CONTRACT, IF THERE ARE QUESTIONS ABOUT INTENT, CLARITY, APPLICATION OF NOTES, OR WORK SHOWN OR SPECIFIED, OR IF CONFLICTING DIRECTIONS ARE FOUND IN THE DOCUMENTS, THE GENERAL CONTRACTOR SHALL REQUEST WRITTEN CLARIFICATION FROM THE OWNER'S REPRESENTATIVE OR ARCHITECT/ENGINEER. ANY CLARIFICATIONS OR INTERPRETATIONS OF THE CONTRACT DOCUMENTS PROVIDED AFTER CONTRACT AWARD SHALL BE AT NO ADDITIONAL COST. 9. CONTRACTOR SHALL NOT SCALE DRAWINGS FOR CONSTRUCTION PURPOSES. IN THE EVENT OF AN OMISSION OF NECESSARY DIMENSIONS OR INFORMATION, CONTRACTOR SHALL NOTIFY THE OWNER'S REPRESENTATIVE OR ARCHITECT/ ENGINEER. FIGURED AND CALCULATED DIMENSIONS TAKES PRECEDENCE OVER SCALED MEASUREMENTS. DETAIL DRAWINGS AND LARGER SCALE DRAWINGS TAKES PRECEDENCE OVER SMALLER SCALE DRAWINGS. ALL PLAN DETAILS AND WALL SECTIONS ARE ASSUMED TO BE TYPICAL CONDITIONS UNLESS DETAILED OR NOTED OTHERWISE. 10. SOME STANDARD SYMBOLS, ABBREVIATIONS AND DETAILS INDICATED IN CONTRACT DOCUMENTS MAY NOT BE APPLICABLE TO THIS SPECIFIC CONTRACT ISSUE. 11. DRAWING DETAILS ARE CONCEPTUAL IN NATURE AND ACTUAL FIELD CONDITIONS MAY VARY SLIGHTLY FROM CONCEPTUAL DEPICTIONS. DETAILS LABELED "TYPICAL DETAILS" ON DRAWINGS APPLY TO SITUATIONS THAT ARE THE SAME OR SIMILAR TO THOSE SPECIFICALLY DETAILED. SUCH DETAILS APPLY WHETHER OR NOT DETAILS ARE REFERENCED AT EACH LOCATION. 12. SUBSTITUTIONS ARE SUBJECT TO THE APPROVAL OF THE OWNER. IF A SUBSTITUTION IS PROPOSED, SUBMIT COMPLETE SPECIFICATION AND PERFORMANCE DETAILS FOR EVALUATION. IF SUBSTITUTIONS ARE APPROVED, NOTIFY ALL OTHER CONTRACTORS AND SUBCONTRACTORS AFFECTED BY THE CHANGE AND FULLY COORDINATE ALL RELATED WORK. ANY COSTS RESULTING FROM THE SUBSTITUTION AND CHANGE IS THE RESPONSIBILITY OF THE CONTRACTOR. 13. COORDINATE AND PERFORM WORK BASED ONLY ON REVIEWED/ CERTIFIED SHOP DRAWINGS, A FIELD CHECK OF EXISTING CONDITIONS, AND INSPECTION OF NEWLY INSTALLED WORK. VERIFY THE LATEST REVISION OF CONTRACT DOCUMENTS, INCLUDING ALL INTERFACING DISCIPLINE DRAWINGS, BEFORE PROCEEDING WITH THE PROCUREMENT, DETAILING, FABRICATION OR INSTALLATION OF THE WORK. ANY SYSTEMS OR EQUIPMENT INSTALLED PRIOR TO REVIEW OF SHOP DRAWINGS BECOMES THE RESPONSIBILITY OF THE CONTRACTOR. 14. ALL EQUIPMENT SHALL BE INSTALLED IN FULL ACCORDANCE WITH MANUFACTURER'S DATA AND INSTALLATION INSTRUCTIONS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO CHECK AND CONFORM TO MANUFACTURER SPECIFICATIONS AND REQUIREMENTS PRIOR TO STARTING THE WORK. VERIFY SIZE, LOCATIONS AND CHARACTERISTICS OF ALL EQUIPMENT TO BE FURNISHED WITH MANUFACTURER OR SUPPLIERS BEFORE COMMENCEMENT OF CONSTRUCTION. VERIFY SIZE AND LOCATIONS OF ALL OPENINGS AND SUPPORTS WITH ACTUAL EQUIPMENT PURCHASED. REFER TO MANUFACTURERS STANDARD DETAILS FOR INSTALLATION. 15. ALL EQUIPMENT AND SYSTEMS SHALL BE COMPLETE AND OPERATIONAL IN ALL RESPECTS, SECURED IN LOCATION AND PROPERLY ADJUSTED. PROVIDE OPERATIONS AND MAINTENANCE MANUALS FOR THE OWNER AT THE COMPLETION OF THE WORK. 16. FULLY WARRANT ALL MATERIALS, EQUIPMENT AND WORKMANSHIP FOR ONE (1) YEAR FROM DATE OF ACCEPTANCE, UNLESS OTHERWISE SPECIFIED. REPAIR OR REPLACE WITHOUT CHARGE TO THE OWNER ALL ITEMS FOUND DEFECTIVE DURING THE WARRANTY PERIOD. 17. BEFORE PENETRATING EXISTING CONCRETE OR SOIL SURFACES, CONSULT WITH ALL LOCAL UTILITIES' PROGRAMS FOR THE AREA OF WORK AND VE RIFY LOCATION OF ALL EXISTING UNDERGROUND UTILITIES AND STRUCTURES BY USE OF "ELECTRONIC" OR SIMILAR NON -INVASIVE DETECTOR DEVICES. IF POTENTIAL INTERFERENCES ARE DISCOVERED, PROPOSE ALTERNATE ROUTING AND ASSOCIATED COSTS TO THE OWNER'S REPRESENTATIVE OR ARCHITECT/ENGINEER FOR APPROVAL BEFORE PROCEEDING. 18. MAINTAIN MINIMUM CLEARANCE REQUIREMENTS OF EQUIPMENT MANUFACTURER'S SPECIFICATIONS OR RECOMMENDATIONS, OWNER STANDARDS, NATIO NAL ELECTRICAL CODE (NEC), AND ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES, AND REGULATIONS. 19. MAINTAIN A MINIMUM OF 6'-8" HEADROOM CLEARANCE FOR BULKHEADS, SUPPORTS AND UTILITIES PASSING OVER WALKWAYS, PLATFORMS OR CATWALKS. ARCHITECTURAL NOTES MISCELLANEOUS SUPPORT RELATED NOTES 1. PROVIDE SUPPLEMENTARY OR MISCELLANEOUS STEEL FOR SUPPORT, SWAY BRACING, CROSS -BRACING, AND ANCHORAGE OF BUILDING SYSTEMS OR UTILITIES, IN ORDER TO MEET SITE SEISMIC AND SYSTEM SPECIFIC INSTALLATION AND OPERATING CONDITIONS. 2. COORDINATE SUPPLEMENTARY OR MISCELLANEOUS STEEL WITH THE PRIMARY STRUCTURAL STEEL WORK. SUPPORT, BRACE, CROSS-BRACE, GUIDE AND ANCHOR AS REQUIRED SO AS TO IMPOSE NO OVER STRESSING OF THE BUILDING STRUCTURE BEYOND STATED LOADS INDICATED ON THE STRUCTURAL DRAWINGS. 3. DO NOT WELD TO, CUT OR DRILL BUILDING STEEL. 4. DO NOT WELD SUPPLEMENTARY OR MISCELLANEOUS STEEL TO BUILDING STEEL WITHOUT PRIOR WRITTEN APPROVAL OF PROPOSED DETAIL BY THE S TRUCTURAL ENGINEER. WELDING TO SUPPLEMENTARY STEEL IS PERMITTED. 5. DO NOT HANG SUPPORTS FROM TOP CHORD OF TRUSS. USE ONLY APPROVED BEAM CLAMPS, C-CLAMPS ARE PROHIBITED. DEMOLITION NOTES 1. PLAN AND SCHEDULE CONSTRUCTION AND DEMOLITION ACTIVITIES TO AVOID INTERFERENCE AND TO MINIMIZE DISRUPTION OF THE OWNER'S OPERATIONS. 2. SCHEDULE AND COORDINATE ALL DEMOLITION WORK AND UTILITY SHUT DOWNS AND TIE-INS WITH THE OWNERS REPRESENTATIVE. PROCEED WITH WORK ONLY AFTER RECEIPT OF WRITTEN AUTHORIZATION. 3. DEMOLISHED MATERIALS, UNLESS OTHERWISE DIRECTED, SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE PROMPTLY REMOVED FROM THE SITE BEFORE THE END OF EACH WORKDAY. OWNER RETAINED SALVAGED EQUIPMENT SHALL BE PROPERLY PROTECTED FOR REUSE OR CRATED FOR PROTECTION AND DELIVERED TO THE OWNER'S SITE STORAGE. ALL HAZARDOUS MATERIALS SHALL BE PROPERLY DISPOSED OF OFF SITE AND PER ALL APPLICABLE FEDERAL, STATE ANDLOCAL CODES. 4. PERFORM CONSTRUCTION AND SELECTIVE DEMOLITION IN A MANNER TO PREVENT DAMAGE TO ANY EXISTING AND NEW STRUCTURES, UTILITIES AND OTHER PROPERTY. 5. ALL CUTTING AND CHASING OF BUILDING CONSTRUCTION SHALL BE IN A NEAT AND WORKMANLIKE MANNER. NEATLY SAWCUT ALL RECTANGULAR OPENINGS, SET SLEEVES THROUGH OPENINGS, AND FINISH PATCH OR PROVIDE TRIM AROUND OPENINGS. CORE DRILL AND SLEEVE ALL ROUND OPENINGS. 6. REPAIR SURFACES THAT HAVE BEEN DAMAGED BY THE WORK. REPAIR DAMAGE TO MATCH EXISTING CONSTRUCTION, INCLUDING BUT NOT LIMITED TO WEATHER AND FIRE SEALING, INSULATING, PATCHING AND PAINTING TO MATCH. 1. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR SITE SAFETY AND CONSTRUCTION MEANS AND METHODS IN THE PERFORMANCE OF THE WORK. PROVIDE ALL MEASURES REQUIRED TO PROTECT THE STRUCTURE, WORKERS AND OTHER PERSONS DURING CONSTRUCTION OPERATIONS. 2. CONTRACTOR TO COMPLY WITH ALL OSHA REGULATIONS, AND ANY OTHER SITE SAFETY REQUIREMENTS OF THE OWNER IN THE PERFORMANCE OF THE WORK. ALL WORK SHALL BE PERFORMED IN A SAFE MANNER AND ALL CONTRACTOR EMPLOYEES SHALL AT ALL TIMES WORK IN COMPLIANCE WITH THE OWNER'S SAFETY REGULATIONS AND ANY GENERAL CONTRACTOR SAFETY REQUIREMENTS. 3. PROVIDE ADEQUATE BRACING AND SHORING FOR CONSTRUCTION EQUIPMENT AND FOR THE BUILDING. PROVIDE SCAFFOLDING, SHEETING, TEMPORARY BARRIERS, BRACING OF EXCAVATIONS AND OTHER TEMPORARY SUPPORTS AS REQUIRED. DO NOT STORE OR STACK CONSTRUCTION MATERIALS ON ERECTED FLOORS OR ROOFS IN EXCESS OF 80 PERCENT OF THE SPECIFIED DESIGN LIVE LOAD. MINIMIZE DYNAMIC IMPACT TO EXISTING STRUCTURES WHEN PLACING MATERIALS ON FLOORS OR ROOFS. 4. DO NOT OBSTRUCT EXISTING BUILDING DOORS OR EGRESS PATHS DURING THE PERFORMANCE OF THE WORK. 5. CONTRACTOR SHALL CLEAN THE SITE OF CONSTRUCTION DEBRIS TO MAINTAIN A SAFE ENVIRONMENT ON A DAILY BASIS. LEGALLY DISPOSE OF ALL HAZARDOUS MATERIALS. 1. ALL FINISH FLOOR ELEVATIONS ARE FOR ARCHITECTURAL PURPOSES ONLY. REFER TO CIVIL AND STRUCTURAL DRAWINGS FOR ACTUAL ELEVATIONS AND RELATIONSHIP TO SITE BENCHMARKS. 2. COORDINATE WITH MECHANICAL CONTRACTOR THE LOCATIONS OF ALL FLOOR DRAINS. 3. TRANSITION OF DIFFERENT FLOORING MATERIALS AT DOORWAYS SHALL OCCUR AT CENTERLINE OF DOORS AND SHALL BE ½" HIGH MAXIMUM. 4. ALL PLAN DIMENSIONS ARE TO FINISHED FACE OF FINISHED WALLS, FACE OF MASONRY, AND CENTERLINE OF COLUMNS, UNLESS NOTED OTHERWIS E. 5. PARTITIONS ARE TO EXTEND AND SEAL AGAINST THE BOTTOM OF THE DECK ABOVE UNLESS OTHERWISE NOTED. 6. INSTALL METAL TRIM ON ALL GYPSUM BOARD EDGES ABUTTING OTHER MATERIALS OR STOPS SHORT OF OTHER MATERIALS TO FORM A REVEAL OR RECESS. USE METAL CORNER BEADS ON ALL GYPSUM BOARD EXTERIOR CORNERS. 7. ADD SUFFICIENT BLOCKING IN STUD WALLS TO SUPPORT ALL ITEMS OR EQUIPMENT SHOWN OR SPECIFIED TO BE ATTACHED TO WALLS. PROVIDE ADDITIONAL STRUCTURAL SUPPORT (PLATES, ANGLES, CHANNELS, ETC.) WITHIN WALLS WHERE WEIGHT OF ATTACHED ITEMS EXCEED WALL CAPACITY. PROVIDE BACKING PLATES OR BLOCKING FOR ANY OWNER FURNISHED OR INSTALLED ITEMS. 8. PAINT ALL WALL SURFACES, DOOR FRAMES, BULKHEADS AND CEILINGS IN ROOMS WHERE INDICATED ON PLANS OR ROOM FINISH SCHEDULE. PAINT BEHIND ALL MOVEABLE ITEMS ADJACENT TO WALLS RECEIVING PAINT AND RELOCATE ITEMS AS NECESSARY. 9. ALL EXTERIOR SURFACES TO HAVE A TEMPORARY OR PERMANENT WEATHER RESISTIVE BARRIER DURING CONSTRUCTION OPERATIONS TO PROTECT TH E BUILDING INTERIOR AND WALL SURFACES. EXTERIOR OPENINGS SHALL BE FLASHED IN SUCH A MANNER AS TO MAKE THEM WATERPROOF. 10. THE AREA OF WORK SHALL BE MAINTAINED WEATHER TIGHT AND IN A SECURED CONDITION AT ALL TIMES. THE CONTRACTOR SHALL TAKE ALL PRECAUTIONS NECESSARY TO SECURE THE AREA OF WORK. 11. REFER TO FLOOR AND REFLECTED CEILING PLANS AND MECHANICAL AND ELECTRICAL DRAWINGS FOR SPACE ALLOCATIONS IN ROUTING OF ALL MECHANICAL AND ELECTRICAL WORK INCLUDING DIFFUSERS, REGISTERS, GRILLES, LIGHTS, ETC. THE REFLECTED CEILING PLAN LOCATIONS SHALL BE ADHERED TO UNLESS OTHERWISE NOTED ON DRAWINGS. EXCEPTIONS SHALL REQUIRE SPECIFIC WRITTEN APPROVAL BY THE OWNER'S REPRESENTATIVE OR ARCHITECT/ ENGINEER. NOTE THAT ELECTRIC LIGHT FIXTURE LOCATIONS AND FIRE SPRINKLER HEADS SHALL TAKE PRECEDENCE OVER OTHER UTILITY ITEMS IN ANY AND ALL LOCATIONS FOR AREAS WITH OR WITHOUT CEILINGS; THE CONTRACTOR SHALL COORDINATE AS REQUIRED, AND IF THERE IS NO APPARENT SOLUTION TO COORDINATION ISSUE, CONTACT TH E OWNER'S REPRESENTATIVE OR ARCHITECT-ENGINEER FOR A RESOLUTION. 12. REFER TO STRUCTURAL DRAWINGS FOR SUPPORT STRUCTURE INFORMATION, DETAILS AND DIMENSIONS NOT INDICATED ON THE ARCHITECTURAL DRAWINGS. REPORT ANY DISCREPANCIES BETWEEN THE ARCHITECTURAL AND STRUCTURAL DRAWINGS TO THE ARCHITECT/ ENGINEER OR OWNER'S REPRESENTATIVE, PRIOR T O CONSTRUCTION. 13. COORDINATE MECHANICAL AND ELECTRICAL EQUIPMENT CONCRETE PADS AND ROOF CURB LOCATIONS, SIZES, SUPPORTS AND CONSTRUCTION REQUIREMENTS, ONLY WITH REVIEWED AND CERTIFIED SHOP DRAWINGS OF THE RELATED TRADES. 14. REFER TO AND COORDINATE WITH STRUCTURAL DRAWINGS FOR ALL FLOOR AND EXTERIOR WALL PENETRATIONS. INSULATE AND WATERTIGHT SEAL ALL EXTERIOR WALL PENETRATIONS. 15. REFER TO MECHANICAL AND ELECTRICAL DRAWINGS AND THE SPECIFICATIONS FOR WALL, FLOOR AND BUILDING SURFACES PENETRATION AND SEALING REQUIREMENTS. FIRE STOP ALL PENETRATIONS OF FIRE RATED WALL OR FIRE RATED FLOOR OPENINGS PER TESTED UL ASSEMBLIES AND AS REQUIRED BY CODE. 16. PROVIDE WALL AND CEILING ACCESS DOORS OR AS MAY BE REQUIRED BY CODE OR TO PROPERLY SERVICE OR ADJUST ALL VALVES, DAMPERS, CLEAN-OUTS, ELECTRICAL JUNCTION BOXES AND OTHER DEVICES. 1. CONTRACTOR TO VERIFY ALL DIMENSIONS AND CONDITIONS AT THE SITE AND NOTIFY THE OWNER OF ANY DISCREPANCIES PRIOR TO PROCEDING WITH THE WORK. 2. ALL OPENINGS IN EXISTING WALLS AND FLOORS WHERE MECHANICAL AND ELECTRICAL EQUIPMENT, DUCTS, CONDUITS, ETC. ARE REMOVED ARE TO BE FILLED IN WITH CORRESPONDING MATERIALS AND PATCHED AND PAINTED TO MATCH ADJACENT SURFACES, SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR LOCATIONS. BID ALTERNATES 1. TRENCH FOOTING VS FLOATING SLAB CONDITION. ESTIMATE PRICES AND VERIFY WITH OWNER WHICH DIRECTION TO GO WITH. REFER TO AE3 SHEET SERIES IN ARCHITECTURAL DRAWING AND STRUCTURAL DRAWINGS. 2. ADDITIONAL EXTERIOR WATER FOUNTAIN IF APPROVED BY OWNER. REFER TO SHEET AE1-100 AND PLUMBING DRAWINGS. No. DESCRIPTION DATE 0 PERMIT 2020-08-04 1. CONTRACTOR TO PROVIDE AND INSTALL INTERIOR BARRIER-FREE SIGNAGE FOR ADULT RESTROOM(S) AND ANY OTHER BARRIER-FREE SIGNAGE AS REQUIRED BY THE LOCAL AUTHORITY HAVING JURISDICTION. 2. ALL BARRIER-FREE SIGNAGE SHALL COMPLY WITH ICC/ANSI A117.1. 3. REFER TO CIVIL DRAWINGS FOR SITE RELATED SIGNAGE. ADA/BARRIER-FREE SIGNAGE 10/29/20