Loading...
HomeMy WebLinkAbout13441 Kingsbury Dr- Proposed Floor Plan26'-2" 13'-4" 11'-11"8'-1"9'-5"13'-4"21'-6"4'-5"19'-2"11'-11" 12'-3"13'-1"51'-5" 1073 OLIVER AVENUE | INDIANAPOLIS, IN 46221 (317) 328 - 1704 email: admin@riveragroupindy.com DRAWN BY IZEL CHACON DATE CERTIFIED BY OCTOBER 13,2020 13441 KINGSBURY DRCARMEL, INDIANA 46032A2.21SCALE: 1/8" =1' Proposed SECOND FLOOR NORTH 1 PROPOSED PLAN KEYNOTES: x PROPOSED BARN DOORS GENERAL INT. FINISH NOTES: 1. ALL INTERIOR FINISH MATERIALS SHALL BE SELECTED BY OWNER- OBTAIN OWNER APPROVAL PRIOR TO ORDERING. 2. REFER TO PROPOSED FLOOR PLANS FOR FURNITURE AND FIXTURE LAYOUT (VERIFY WITH OWNER ). GENERAL PLAN NOTES: 1. THESE DRAWINGS ARE INTENDED TO OUTLINE THE GENERAL SCOPE OF THE WORK. CONTRACTORS SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE STARTING ANY WORK. CONTRACTORS SHALL ALSO BE RESPONSIBLE FOR ADHERING TO ALL APPLICABLE CODES AND GENERALLY ACCEPTED TRADE PRACTICES. 2. ALL DIMENSIONS ARE FROM FACE OF STUD TO FACE OF STUD, MASONRY, OR EXISTING WALL SURFACE, UNLESS NOTED OTHERWISE. FIELD VERIFY ALL EXISTING DIMENSIONS AS REQUIRED TO CONFIRM LAYOUT. 3. PROVIDE NECESSARY BLOCKING CONCEALED WITHIN THE CONSTRUCTION, AS REQUIRED FOR ANY AND ALL ITEMS THAT MUST BE SECURED TO THE WALL. 4. REFER TO PROPOSED FLOOR PLANS FOR ALL PLUMBING FIXTURE LOCATIONS. PROPOSED FLOOR PLANS ARE FOR DESIGN INTENT ONLY. 5. EACH CONTRACTOR SHALL VERIFY EXISTING CONDITIONS. CONTRACTOR SHALL REPORT ANY DISCREPANCIES OR OMISSIONS THAT MAY OCCUR TO THE ARCHITECT OR OWNER. WALL LEGEND EXISTING WALLS TO REMAIN NEW DOOR AND FRAME NEW INTERIOR / EXTERIOR WALL 2 EGRESS WINDOWS 3 SMOKE DETECTOR AND CARBON MONOXIDE MASTER BEDROOM MASTER CLOSETBEDROOM BEDROOM BEDROOM BATHROOM HALLWAYBATHROOM CLOSET CLOSETCLOSET CLOSETCLOSET BATHROOMCLO.CLO. DOWNDOWN S/C S/C S/C S/C S/C S/C 1 1 WINDOW SCHEDULE MARK COUNT WIDTHHEIGHT 100 101 102 103 104 105 106 2 2 1 3 2 2 1 23 35 32.5 30.5 25.5 20.5 44.5 53 61.5 61.5 53 66 55.5 55.5 XXX 100 100 101 101 102 103 104 104 103 103 105 105106 3 3 3 3 3 322 2 2 2 EGRESS NOTE: ALL SLEEPING ROOM WINDOWS ARE SIZED TO MEET EGRESS AS REQUIRED BY 2018 INTERNATIONAL RESIDENTIAL CODE WITH INDIANA CLEAR OPENING FOR TYPE 101: S/C SMOKE DETECTOR WITH INTEGRATED CARBON MONOXIDE ·2'-11" x 5'-1.5" double hung ·Opening area 35" x 61.5" ·Net opening area : 2.916 x 5.125 = 14.945 CLEAR OPENING FOR TYPE 102: ·2'-8.5" x 5'-1.5" double hung ·Opening area 32.5" 61.5" ·Net opening area : 2.708 x 5.125 = 14.879 CLEAR OPENING FOR TYPE 103: ·2'-6.5" x 4'-5" double hung ·Opening area 30.5" 53" ·Net opening area : 2.542 x 4.416 = 11.225 CLEAR OPENING FOR TYPE 104: ·2'-1.5" x 5'-6" double hung ·Opening area 25" x 66" ·Net opening area : 2.125 x 5.5 = 11.687 CLEAR OPENING FOR TYPE 105: ·1'-8.5" x 4'-7.5" double hung ·Opening area 20.5" x 55.5" ·Net opening area : 1.708 x 4.625 = 7.90 CLEAR OPENING FOR TYPE 106: ·3'-8.5" x 4'-7.5" double hung ·Opening area 44.5" x 55.5" ·Net opening area : 3.708 x 4.625 = 17.15 4 2-2 x 12 4 10/30/20