HomeMy WebLinkAbout13441 Kingsbury Dr- Proposed Floor Plan26'-2"
13'-4"
11'-11"8'-1"9'-5"13'-4"21'-6"4'-5"19'-2"11'-11"
12'-3"13'-1"51'-5"
1073 OLIVER AVENUE | INDIANAPOLIS, IN 46221
(317) 328 - 1704 email: admin@riveragroupindy.com
DRAWN BY
IZEL CHACON
DATE
CERTIFIED BY
OCTOBER 13,2020
13441 KINGSBURY DRCARMEL, INDIANA 46032A2.21SCALE: 1/8" =1'
Proposed
SECOND FLOOR
NORTH
1
PROPOSED PLAN KEYNOTES: x
PROPOSED BARN DOORS
GENERAL INT. FINISH NOTES:
1. ALL INTERIOR FINISH MATERIALS SHALL BE SELECTED BY
OWNER- OBTAIN OWNER APPROVAL PRIOR TO ORDERING.
2. REFER TO PROPOSED FLOOR PLANS FOR FURNITURE AND
FIXTURE LAYOUT (VERIFY WITH OWNER ).
GENERAL PLAN NOTES:
1. THESE DRAWINGS ARE INTENDED TO OUTLINE THE GENERAL
SCOPE OF THE WORK. CONTRACTORS SHALL FIELD VERIFY
ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE
STARTING ANY WORK. CONTRACTORS SHALL ALSO BE
RESPONSIBLE FOR ADHERING TO ALL APPLICABLE CODES
AND GENERALLY ACCEPTED TRADE PRACTICES.
2. ALL DIMENSIONS ARE FROM FACE OF STUD TO FACE OF STUD,
MASONRY, OR EXISTING WALL SURFACE, UNLESS NOTED
OTHERWISE. FIELD VERIFY ALL EXISTING DIMENSIONS AS
REQUIRED TO CONFIRM LAYOUT.
3. PROVIDE NECESSARY BLOCKING CONCEALED WITHIN THE
CONSTRUCTION, AS REQUIRED FOR ANY AND ALL ITEMS THAT
MUST BE SECURED TO THE WALL.
4. REFER TO PROPOSED FLOOR PLANS FOR ALL PLUMBING
FIXTURE LOCATIONS. PROPOSED FLOOR PLANS ARE FOR
DESIGN INTENT ONLY.
5. EACH CONTRACTOR SHALL VERIFY EXISTING CONDITIONS.
CONTRACTOR SHALL REPORT ANY DISCREPANCIES OR
OMISSIONS THAT MAY OCCUR TO THE ARCHITECT OR OWNER.
WALL LEGEND
EXISTING WALLS TO REMAIN
NEW DOOR AND FRAME
NEW INTERIOR / EXTERIOR WALL
2 EGRESS WINDOWS
3 SMOKE DETECTOR AND CARBON MONOXIDE
MASTER
BEDROOM
MASTER
CLOSETBEDROOM
BEDROOM
BEDROOM
BATHROOM
HALLWAYBATHROOM
CLOSET
CLOSETCLOSET CLOSETCLOSET
BATHROOMCLO.CLO. DOWNDOWN
S/C
S/C
S/C
S/C
S/C
S/C
1
1
WINDOW SCHEDULE
MARK COUNT WIDTHHEIGHT
100
101
102
103
104
105
106
2
2
1
3
2
2
1
23
35
32.5
30.5
25.5
20.5
44.5
53
61.5
61.5
53
66
55.5
55.5
XXX
100
100
101
101
102
103
104 104
103 103
105 105106
3
3
3
3
3
322
2
2
2
EGRESS NOTE:
ALL SLEEPING ROOM WINDOWS ARE SIZED TO MEET
EGRESS AS REQUIRED BY 2018 INTERNATIONAL RESIDENTIAL
CODE WITH INDIANA
CLEAR OPENING FOR TYPE 101:
S/C SMOKE DETECTOR WITH INTEGRATED
CARBON MONOXIDE
·2'-11" x 5'-1.5" double hung
·Opening area 35" x 61.5"
·Net opening area : 2.916 x 5.125 = 14.945
CLEAR OPENING FOR TYPE 102:
·2'-8.5" x 5'-1.5" double hung
·Opening area 32.5" 61.5"
·Net opening area : 2.708 x 5.125 = 14.879
CLEAR OPENING FOR TYPE 103:
·2'-6.5" x 4'-5" double hung
·Opening area 30.5" 53"
·Net opening area : 2.542 x 4.416 = 11.225
CLEAR OPENING FOR TYPE 104:
·2'-1.5" x 5'-6" double hung
·Opening area 25" x 66"
·Net opening area : 2.125 x 5.5 = 11.687
CLEAR OPENING FOR TYPE 105:
·1'-8.5" x 4'-7.5" double hung
·Opening area 20.5" x 55.5"
·Net opening area : 1.708 x 4.625 = 7.90
CLEAR OPENING FOR TYPE 106:
·3'-8.5" x 4'-7.5" double hung
·Opening area 44.5" x 55.5"
·Net opening area : 3.708 x 4.625 = 17.15
4 2-2 x 12
4
10/30/20