HomeMy WebLinkAboutT 100 (100520)PROPERTY LINE 73.00'
PROPERTY LINE 73.00'PROPERTY LINE 165.46'PROPERTY LINE 165.45'LOT #2 IN CARMEL VIEW PER REPLAT
THEREOF, RECORDED IN PLAT BOOK 2,
PAGES 36 AND 37 IN THE OFFICE OF
HAMILTON COUNTY RECORDER
PARCEL ID NO. 16-10-30-03-04-028.000
OWNERS: CONNOR & LYDIA RAY 15'-0"UTILITY EASEMENT7'-6"
DRAINAGE
AND
UTILITY
EASEMENT
C/L CARMEL VIEW DRIVE 25'-0"NOTE: SITE INFORMATION IS FROM A
SURVEY PREPARED BY WEIHE
ENGINEERS, INC. DATED 1970.
EXISTING
RESIDENCE
PROPOSED
MASTER
SUITE
ADDITION
PROPOSED
GARAGE/
HOME
OFICE
ADDITION
PROPOSED
SCREENED
PORCH
ADDITION
PREVIOUS
ADDITION TO BE
DEMOLISHED
55.00' 44.00' 35.00'20.00'10.50' 55.00' 7.50' 20.00' 46.45'EXISTING
DRIVE
NEW FRONT
PORCH
NEW 5' CONC
WALK
STRUCTURAL & MATERIAL SPECIFICATIONS
DESIGN LOADS
DEAD LIVE USE (LB./ SQUARE FOOT)
LOAD LOAD
10 20 ATTICS ACCESSIBLE BY SCUTTLE OR MEANS
OTHER THAN STAIR; CLEAR HEIGHT PERMITS LIMITED
STORAGE OF HOUSEHOLD ITEMS
20 20 (SNOW) ROOF
10 10 ALL OTHER ATTIC SPACES, NO STORAGE, ROOF
SLOPE 3:12 MAX
10 40 EXTERIOR DECKS
16.4 WIND PRESSURE: BUILDINGS UP TO 30 FT AT 90 MPH.
90 MPH WIND SPEED
1500 PSF MINIMUM SOIL BEARING PRESSURE
ALLOWABLE DEFLECTIONS H = HEIGHT L = LENGTH
L/180 RAFTERS HAVING SLOPES GREATER THAN
3/12 WITH NO FINISHED CEILING ATTACHED
TO RAFTERS
H/180 INTERIOR WALLS AND PARTITIONS
CONCRETE
ALL CONCRETE WORK SHALL BE DONE IN ACCORDANCE WITH ALL APPLICABLE
SECTIONS OF THE AMERICAN CONCRETE INSTITUTE (ACI)'S MOST RECENT
EDITION OF THE FOLLOWING GUIDELINES AND SPECIFICATIONS:
ACI 318.1 BUILDING CODE REQUIREMENTS FOR STRUCTURAL PLAIN CONCRETE ACI 301
SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS
ACI 318 & ACI 318R BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE
CAST-IN-PLACE CONCRETE SHALL BE READY MIX ASTM C94; CONCRETE FOR
FOOTINGS TO BE F'C = 3,000 PSI; CONCRETE FOR GARAGE SLABS TO BE
F'C = 4,000 PSI; ALL OTHER CONCRETE TO BE F'C = 3,500 PSI, ALL
STRENGTHS MEASURED AT 28 DAYS.
ALL REINFORCING STEEL TO BE ASTM 615 (GRADE 60) WITH 60,000 PSI (MINIMUM) YIELD
TRENGTH. ALL WELDED WIRE FABRIC (WWF) SHALL BE ASTM 185. CONCRETE
COVER: 3" AT EARTH FORM, 1 1/2" AT FORMWORK, SLABS--MID DEPTH,
UNLESS OTHERWISE NOTED.
CONCRETE FORMWORK TO BE ADEQUATELY TIED AND BRACED. FORM SHALL NOT
BE STRIPPED UNTIL THE WALL HAS CURED FOR SEVEN DAYS.
ALL CAST-IN-PLACE CONCRETE SHALL BE POURED CONTINUOUSLY WITH NO
COLD JOINTS, AND VIBRATED ADEQUATELY TO PREVENT AIR POCKETS AND
HONEYCOMB EFFECTS. IF A COLD JOINT CANNOT BE AVOIDED,
REINFORCING SHALL EXTEND THROUGH THE COLD JOINT UNLESS
OTHERWISE NOTED, COLD JOINTS ARE THE RESPONSIBILITY OF THE
CONTRACTOR
ALL CONTINUOUS FOOTINGS ARE TO BE 24" X 10" WITH (2) #5 BARS CONTINUOUS
UNLESS OTHERWISE NOTED.
CONCRETE SLABS TO BE 4" THICK, OVER 6 MIL VAPOR BARRIER, OVER 4" MINIMUM
WASHED GRAVEL (3/4" MINIMUM DIAMETER) WITH 6 X 6 X10/10 WELDED WIRE
FABRIC (WWF) OR #4 BARS AT 24" O.C. EACH WAY UNLESS OTHERWISE
NOTED. CONTROL JOINTS TO BE PROVIDED AT 10'-0" O.C. MAXIMUM AND 1"
DEEP. SLOPE BASEMENT SLABS TO FLOOR DRAINS. SLOPE GARAGE SLABS
1/8" PER FOOT MINIMUM AND 1/4" PER FOOT MAXIMUM TOWARDS GARAGE
DOORS.
BEAM POCKETS TO BE SET TO MATCH DEPTH OF STEEL, TO BE 1" WIDER THAN
THE BEAM FLANGES, AND TO HAVE A MINIMUM OF 6" BEAM BEARING AREA
INTO THE WIDTH OF THE CONCRETE WALL.
OPENINGS IN CONCRETE WALLS TO HAVE (2) #4 BARS VERTICAL AT EACH SIDE
OF OPENING, FULL HEIGHT OF THE CONCRETE POUR. CONCRETE LINTELS
TO HAVE (2) #4 BARS DIRECTLY ABOVE THE OPENINGS AND EXTEND 30"
PAST OPENING (UNLESS OTHERWISE NOTED). (2) #4 BARS AT TOP OF WALL
TO BE CONTINUOUS ACROSS LINTEL AREA.
WOOD
WALL STUDS TO BE STUD GRADE SO. YELLOW PINE or SPF. ALL OTHER LUMBER TO
BE SOUTHERN YELLOW PINE OR SPF #1 MIN. MICRO-LAM MEMBERS TO HAVE
AN FB = 2800
PSI; E = 2,000,000 PSI.
PRESSURE TREATED LUMBER TO BE AWPA, WATERBORNE (CCA) TREATED
YELLOW PINE, GRADE 2 FOR ABOVE GROUND USE. ALL CONSTRUCTION
GRADE WOOD IN CONTACT WITH CONCRETE OR WITHIN 8" OF GRADE TO BE
PRESSURE TREATED. ALL BOTTOM PLATES FOR WOOD WALLS RESTING ON
CONCRETE TO BE PRESSURE TREATED. ALL STRUCTURAL LUMBER
EXPOSED TO EXTERIOR TO BE PRESSURE TREATED OR APPROVED SPECIES.
PLYWOOD TO BE APA PANEL SPECIFICATIONS RATED FOR SPECIES, PANEL
GRADE, SPAN RATING, THICKNESS, EXPOSURE CLASSIFICATION, AND MILL
LUMBER. PLYWOOD SHALL BE GAPPED AS PER APA RECOMENDATIONS ON
WALL, FLOOR AND ROOF SHEATING. USE CLIPS AT ALL FREE EDGES.
TYPICAL
HEADER SIZE AT THE FRAME OPENING TO BE (2)2X10 UNLESS
OTHERWISE NOTED.
ALL DOUBLE 2X HEADERS TO BE FASTENED TOGETHER AT THE TOP AND
BOTTOM INTO EACH ADJACENT MEMBER WITH (MINIMUM) 2 ROWS OF 16D
NAILS AT 12" O.C., UNLESS OTHERWISE NOTED. FOR HEADERS GREATER
THAN TWO MEMBERS WIDE, CONTACT DESIGNER FOR FASTENING, UNLESS
NOTED ON PLAN.
LAMINATED VENEER LUMBER (LVL) BEAMS TO BE FASTENED TOGETHER
PER MANUFACTURERS SPECIFICATIONS. ALL TJI'S AND LVL BEAMS TO BE
INSTALLED, BRACED, JOIST HUNG, ETC., ACCORDING TO MANUFACTURERS'
SPECIFICATIONS. BEARING STIFFENERS TO BE ADDED TO ENDS OF ALL
T.J.I.'S.
FIRESTOPPING OF TWO INCH NOMINAL LUMBER SHALL BE PROVIDED TO FORM AN
EFFECTIVE FIRE BARRIER BETWEEN ALL CONCEALED DRAFT OPENINGS,
BOTH VERTICAL AND HORIZONTAL.
BRIDGING IN FLOOR JOISTS TO BE FABRICATED METAL BRIDGING (SECURED AT
BOTH ENDS), OR SOLID BRIDGING OFFSET AND END NAILED. SOLID
BRIDGING TO BE MADE OF 2X MATERIAL OF ONE SIZE SMALLER THAN FLOOR
JOIST DEPTH. ALIGN BOTTOM CHORDS OF SOLID BRIDGING AND BOTTOM OF
FLOOR JOISTS. BRIDGING SHALL NEVER TOUCH BOTTOM OF FLOOR
SHEATHING. SET BRIDGING AT 6'0" O.C.MAXIMUM, UNLESS OTHERWISE
NOTED.
SITE PLAN
SCALE: 1" = 20'-0"
BUILDING CODE NOTES
AUTHORITY HAVING JURISDICTION: HAMILTON COUNTY, INDIANA
GOVERNING CODE: 2020 RESIDENTIAL CODE OF INDIANA
ENERGY CODE COMPLIANCE SHALL BE VIA PRESCRIPTIVE METHOD
INDEX OF DRAWINGS
T 100 COVER SHEET; CODE NOTES; SITE PLAN; CONSTRUCTION NOTES
A 100 EXISTING FIRST FLOOR PLAN AND SELECTIVE DEMO PLAN
A 101 EXISTING AND PROPOSED FOUNDATION PLAN
A 102 PROPOSED FIRST FLOOR PLAN
A 200 EXISTING EXTERIOR ELEVATIONS AND SELECTIVE DEMO
A 201 PROPOSED EAST AND WEST EXTERIOR ELEVATIONS
A 202 PROPOSED NORTH ELEVATION & BUILDING SECTIONS
ROOF SLOPES GREATER THAN 4:12 TO HAVE ONE LAYER OF 15# FELT PAPER
UNDERLAYMENT MINIMUM. ROOF SLOPES BETWEEN 2:12 AND 4:12 TO HAVE 2
LAYERS MINIMUM 15# FELT PAPER PER MANUFACTURER'S RECOMMENDATION.
GUTTERS AND DOWNSPOUTS. PROVIDE METAL GUTTERS AND DOWNSPOUTS
PER PLAN. ALL GUTTERS TO SLOPE TOWARDS DOWNSPOUTS. PROVIDE
GUTTER DRIP FLASH UNDER ROOFING AT ALL GUTTER LOCATIONS.
DOWNSPOUTS TO DISCHARGE TO THE EXISTING UNDERGROUND STORM WATER
REMOVAL SYSTEM.
GLAZING. DOORS, WINDOWS, AND MIRRORS IN HAZARDOUS LOCATIONS
DESCRIBED BELOW SHALL BE EITHER LAMINATED, HEAT STRENGTHENED OR
TEMPERED.
A. INGRESS DOORS, EGRESS DOORS EXCEPT JALOUSIES.
B. FIXED AND SLIDING PANELS OF SLIDING-TYPE DOORS AND PANELS IN
SWINGING DOORS.
C. STORM DOORS
D. ALL UNFRAMED SWINGING DOORS.
E. DOORS AND ENCLOSURES OF HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM
ROOMS, BATHTUBS AND SHOWERS. GLAZING IN ANY PART OF THE BUILDING
WALL ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EDGE OF THE
GLAZING IS LESS THAN 60" ABOVE THE DRAIN INLET AND 36" HORIZONTALLY
FROM THE INSIDE EDGE OF THE TUB OR COMPARTMENT.
F. OPERABLE OR INOPERABLE PANELS ADJACENT TO A DOOR IN ALL
BUILDINGS AND WITHIN THE SAME WALL PLANE AS THE DOOR WHOSE NEAREST
VERTICAL EDGE IS WITHIN 24" ARC OF THE DOOR IN A CLOSED POSITION AND
WHOSE BOTTOM EDGE IS LESS THAN 60" ABOVE THE FLOOR OR WALKING
SURFACE.
G. IN A FIXED OR OPERABLE PANEL HAVING A GLAZED AREA IN EXCESS OF 9
SQUARE FEET WITH LOWEST EDGE LESS THAN 18" ABOVE THE FINISHED FLOOR
LEVEL AND TOP EDGE GREATER THAN 36" ABOVE THE FLOOR OR WALKING
SURFACE WITHIN 36" HORIZONTALLY OF SUCH GLAZING.
H. OPERABLE WINDOWS. EVERY SLEEPING ROOM SHALL HAVE ONE OPERABLE
WINDOW OR EXTERIOR DOOR EGRESS LIMITED TO 44" MAXIMUM SILL HEIGHT X
20" MINIMUM CLEAR OPENING WIDTH X 24" CLEAR OPENING HEIGHT X 5.7
SQUARE FEET MINIMUM NET CLEAR OPENING. GRADE FLOOR EGRESS
WINDOWS SHALL COMPLY EXCEPT REQUIRING 5.7 SQUARE FEET MINIMUM NET
CLEAR OPENING.
COMBO SMOKE/CO DETECTORS. INSTALL U.L. APPROVED DETECTORS, WIRED
TO AC 110 VOLT ELECTRICAL HOUSE CURRENT WITH BATTERY BACKUP. INSTALL
ONE AT EVERY OCCUPIED FLOOR AND BASEMENT; AUDIBLE DISTANCE FROM
SLEEPING AREAS AND STAIR AREAS (EXCLUDING CRAWL SPACES AND
UNFINISHED ATTICS); AND ONE DETECTOR IN EVERY SLEEPING ROOM. WIRE
ALARMS SUCH THAT WHEN ONE ALARM SOUNDS, ALL THE ALARMS WILL SOUND.
WALL BRACING SHALL BE ACCOMPLISHED VIA CONTINUOUS APA RATED WALL
SHEATHING. PROVIDE PANEL BRACING, FULL HEIGHT, NAILED OR SCREWED @ 3"
O.C. AT PANEL EDGES AND @ 6" O.C. AT THE PANEL INTERIOR.
INTERIOR PARTITIONS ARE 2 X 4 WOOD STUDS @ 16" O.C. WITH 1/2" GYPSUM
BOARD, PAINTED, BOTH SIDES, UNLESS NOTED OTHERWISE.
DRYER VENTILATION. DRYER VENT SYSTEMS SHALL BE INDEPENDENT OF ALL
OTHER SYSTEMS AND SHALL CONVEY MOISTURE TO THE OUTDOORS.
EXHAUST. EXHAUST FANS TO VENT DIRECTLY TO EXTERIOR THROUGH
NON-COMBUSTIBLE DUCTS. ALL EXHAUSTS VENTS, ROOF VENTS AND PLUMBING
VENT STACKS SHALL BE LOCATED AT REAR OF STRUCTURE WHENEVER
POSSIBLE.
ALL INTERIOR DOORS TO BE PAINTED IN COLOR AS SELECTED BY THE OWNER.
ALL BASE TRIM BOARD AT HARDWOOD FLOORS TO BE 5-1/4" HIGH WOOD, STYLE
AS SELEVTED, PAINTED IN COLOR AS SELECTED BY OWNER.
CONSTRUCTION NOTES
sheet
scale
issue date
checked
no.
revisions
date
TITLE SHEET
CODE NOTES
DRAWING INDEX
SITE PLAN
THIS DOCUMENT, AND THE IDEAS AND DESIGNS
INCORPORATED HEREIN, IS THE PROPERTY OF LARRY N.
KEITH/ARCHITECT AND IS NOT TO BE USED, IN WHOLE OR
IN PART, FOR ANY OTHER PROJECT,WITHOUT THE
WRITTEN AUTHORIZATION OF LARRY N. KEITH/ARCHITECT.
ALL RIGHTS RESERVED.
1
for
T100
10/05/2020
LARRY N. KEITH
INDIANA REG ARCHITECT N0. AR00033860
EXP DATE: 12/31/2021
Larry N. Keith
11/02/20