HomeMy WebLinkAboutA 101 (100520)44'-0"24'-0" 30'-0"10'-0" 10'-0"55'-0"
16'-4" 18'-8" 20'-0"
10'-0" 10'-0"6'-0" 4'-0" 20'-0"16'-4" 11'-1" 3'-7" 24'-0"21'-1" 3'-11" 5'-0"2 x 10@ 16" O.C.2 x 10@ 16" O.C.2 x 10@ 16" O.C.2 x 10@ 16" O.C.2 x 10@ 16" O.C.2 x 10@ 16" O.C.TREATED
2 x 8
@ 16" O.C.
TREATED
2 x 8
@ 16" O.C.6'-0"7'-11" 3'-6" 7'-7" 2 X 6@ 16" O.C.30'-0"84'-0"A101
GENERAL NOTES:
A. ALL DIMENSIONS TO THE FACE OF FINISHED SURFACE,
CENTERLINE OF POST/COLUMN, OR FACE
OF EXISTING SURFACE UNLESS NOTED
OTHERWISE.
B. ALL WOOD IN CONTACT WITH CONCRETE,
MASONRY OR EARTH SHALL BE PRESSURE
TREATED.
C. CRAWL SPACE ACCESS SHALL BE PROVIDED IN EXISTING
BASEMENT, VIA 24" W X 18" HIGH ACCESS PANELS IN THE
BASEMENT WALL
sheet
scale
issue date
checked
no.
revisions
date
EXISTING AND
PROPOSED
FOUNDATION
PLAN
THIS DOCUMENT, AND THE IDEAS AND DESIGNS
INCORPORATED HEREIN, IS THE PROPERTY OF LARRY N.
KEITH/ARCHITECT AND IS NOT TO BE USED, IN WHOLE OR
IN PART, FOR ANY OTHER PROJECT,WITHOUT THE
WRITTEN AUTHORIZATION OF LARRY N. KEITH/ARCHITECT.
ALL RIGHTS RESERVED.
1
for
1....4" CONC FLOOR SLAB OVER 8 MIL VAPOR BARRIER
OVER 4" DRAINAGE FILL
2....CRAWL SPACE
3....4 X 4 TREATED WOOD POST IN 18" DIA POST HOLE WITH 12"
DEEP CONCRETE FOOTING.
4....EXISTING FLOOR SLAB ON GRADE. PROVIDE 2 X 8 @ 16" O.C.
OVER 8 MIL VAPOR BARRIER ON EXISTING SLAB. INSTALL 3 4"
SUBLOOR TO ALIGN WITH EXISTING SUBFLOOR. FILL CAVITY
WITH 8" THICK BATT INSULATION.
5....THIS AREA HAS 2 X 8@ 16" O.C. WITH 3/4 " PLYWOOD
SUBFLOOR. REMOVE SUBFLOOR. CHECK CONDITION OF
EXISTING FRAMING AND REPLACE IF NECESSARY. INSULATE
PER NOTE 4 ABOVE.
6....THREE 2 X 10 BEAM
7....16" X 16" CONCRETE BLOCK PIER ON 36" X 36" X 12" D
CONCRETE PAD. PAD TO BE REINFORCED WITH THREE #5
REBAR @ 12" O.C. BOTH WAYS
8....EXISTING CONCRETE SLAB ON GRADE
9....EXISTING CRAWL SPACE
10..APPROX LOCATION OF EXISTING CRAWL SPACE ACCESS
11..NEW CRAWL SPACE ACCESS
12..TREATED 2 X 8
13..INFILL AS REQUIRED
SELECTIVE DEMO NOTES:
10/05/2020
EXISTING AND PROPOSED
FOUNDATION PLAN
SCALE: 1/4" = 1'-0"
WALL LEGEND:
EXISTING 8" CONCRETE BLOCK
FOUNDATION WALL AND
REINFORCED CONCRETE FOOTING
NEW 8" CONCRETE BLOCK
FOUNDATION WALL ON 24" W X 12" H
CONCRETE FOOTING W/ TWO #5 REBAR
CONTINUOUS
1
2
2
2
4
3 3 3
5
6
6 7
7
98
10
11
11
12
13
LARRY N. KEITH
INDIANA REG ARCHITECT N0. AR00033860
EXP DATE: 12/31/2021
Larry N. Keith
11/02/20