HomeMy WebLinkAboutCU501 UTILITY DETAILSLSTRUCTURE C
VARIES
RIM ELEV. SEE PLANS
INSTALL RISERS TO RAISE
TOP A", WITH A MAXIMUM
COMBINED HEIGHT OF 12".
INLET PIPE
FINISH GRADE
AGROUT INTERNAL PIPES
AROUND BOOTS
REPLACE LID TO
WATERTIGHT NEENAH
R-1916-F OR EQUAL
CONCRETE ADJUSTING
RINGS LIMITED TO (3) RINGS.
RINGS MUST BE BUTYL
RUBBER COATED WITH
PLASTIC WRAP COVER.
EXISTING MANHOLE
DIA VARIES 4'-0" SUMPOUTLET PIPE
SEE PLANS FOR SIZE & INVERT
INLET PIPE
SEE PLANS FOR SIZE & INVERT
DIA. VARIES
MANHOLE STEPS
ORIFICE SEE TABLE FOR
INVERT AND DIAMETER
RIM ELEV.
WATERTIGHT FLEXIBLE BOOTS MUST
BE USED AT ALL OPENINGS
BED BASE SECTION IN MIN. 6"
COMPACTED #8 GRANULAR MATERIAL
APPLY MINIMUM 10 MIL
BITUMINOUS COATING TO
EXTERIOR OF STRUCTURE
0.80'
ORIFICE SEE TABLE FOR
INVERT AND DIAMETER
CONTROL WEIR SEE
TABLE FOR CREST
ELEV.
CONTROL WEIR SEE
TABLE FOR CREST
ELEV.
RIM ELEV .
GALVANIZED STEEL TRASH RACK GALVANIZED STEEL TRASH RACK
GALVANIZED STEEL TRASH RACK SHALL BE J.R. HOE
(TRASHRACK.COM) LDR OR EQUAL.
UTILITY DETAILS
11640
CU501
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
WEST PARK:
THE CORE
2700 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroup.com
ISSUED FOR CONSTRUCTION 09/10/2020
NOT TO SCALE
EXISTING SANITARY MANHOLE REPAIR2
NOT TO SCALE
CONTROL STRUCTURE1
NOT TO SCALE
CATCH BASIN PIPE3
NOT TO SCALE
WATER MAIN THRUST RESTRAINT7NOT TO SCALE
DRAIN GRATE INLET CASTING TYPE 45NOT USED#
NOTES:
1.PROVIDE IN-BELL GRATE
MATCHING DIMENSION OF
APPROVED PIPE.
2.CATCH BASIN PIPE DIAMETER
SHALL BE LARGE ENOUGH TO
ACCOMMODATE CONNECTING
PIPES, BUT IN NO CASE SHALL BE
LESS THAN 22" DIAMETER
NOTES:
1.NEENAH R-4030 SERIES OR EQUAL
MAY BE USED IN LIEU OF R-4342 IN
ORDER TO MATCH DIAMETER OF
REQUIRED PIPE BELL.
PER CITY STORMWATER RVW 09/21/2020
PER CITY STORMWATER RVW 10/16/2020