HomeMy WebLinkAboutCS512 BRIDGE DETAILSBRIDGE DETAILS
11640
CS512
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
WEST PARK:
THE CORE
2700 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroup.com
ISSUED FOR CONSTRUCTION 09/10/2020
SCALE: NTS
BRIDGE1
FIELD VERIFY
PLAN DIMENSION = 54"
FIELD VERIFY
PLAN DIMENSION = 20'-0"
FIELD VERIFY
PLAN DIMENSION = 20'-0"
PLAN VIEWISOMETRIC VIEW
END ELEVATION FRONT ELEVATION
43" GUARDRAIL
TRANSITION FROM BRIDGE TO ADJACENT
WALK TO BE ADA COMPLIANT
BRIDGE ATTACHMENT PER
MANUFACTURER'S RECOMMENDATION
CONCRETE ABUTMENT, SEE STRUCTURAL
DETAIL 51 SHEET S2.1.1
CUSTOM STEEL COVER UNDER BRIDGE TO
PREVENT CLIMBING OR HANGING ON
BRIDGE STRUCTURE, POWDERCOAT TO
MATCH RAILING
NOTES:
1.PRODUCT BASIS OF DESIGN:
·MANUFACTURER: STREETLIFE
·MODEL #: BRG-BOW-610-137-ARCHED-PC
·DESCRIPTION: 20-FT X 68.9” (OUTSIDE DIMENSION OF BRIDGE RAILING) ARCHED
BOWIE BRIDGE WITH CUSTOM POWDERCOATED STEEL UNDERSIDE, CUMARU
HARDWOOD DECK, POWDERCOATED STEEL RAILING WITH CUMARU HARDWOOD
TOP HANDRAIL.
·POWDERCOAT COLOR: MANUFACTURER'S STANDARD, JET BLACK, RAL 9005
·STREETLIFE SITE FURNISHINGS PRODUCT REPRESENTATIVE:
CONTACT: ALEXANDER VAN ZWEEDEN
WEBSITE: WWW.STREETLIFE.NL
EMAIL: AVZW@STREETLIFEAMERICA.COM
PHONE: 484.496.8280
ESTIMATED LEAD TIME: 13-15 WEEKS AFTER DRAWING AND STRUCTURAL
ANALYSIS APPROVAL
2.CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR THE ENTIRE BRIDGE ASSEMBLY,
INCLUDING BRIDGE ATTACHMENT AND GUARDRAIL, SEALED BY A QUALIFIED
PROFESSIONAL ENGINEER LICENSED IN THE STATE OF INDIANA. STRUCTURAL DESIGN
AND ACCESSIBILITY SHALL BE CODE COMPLIANT FOR THE PROJECT LOCATION.
3.BRIDGE SHALL BE WARRANTED AGAINST DEFECTS IN MATERIAL, CRAFTSMANSHIP, AND
INSTALLATION PER MANUFACTURER'S STANDARD WARRANTY FROM DATE OF
SUBSTANTIAL COMPLETION. PROVIDE OPERATIONS AND MAINTENANCE INSTRUCTIONS
TO OWNER.
4.FOR THE ARCHED WALKING SURFACE OF THE BRIDGE, THE LONGITUDINAL GRADE /
SLOPE OF THE PATH TO CROSS THE BRIDGE SHALL NOT EXCEED 5% IN ORDER TO
MAINTAIN ADA ACCESSIBILITY.
FIELD VERIFY
PLAN DIMENSION = 68.9"
PER CITY STORMWATER RVW 09/21/2020