HomeMy WebLinkAboutCU101 UTILITY PLAND co co D co co D DwDD EG-MH-01 EG-MH-02 EG-CO-01 REPAIR EXISTING SANITARY MANHOLE 2 CU501 REPAIR EXISTING SANITARY MANHOLE 2 CU501 RETROFIT TO TYPE II CLEANOUT 5 CU500 4 CU500 CU500 4 CU500 4 CU500 1,2,3 CU500 1 CU501 CO-4 RIM: 899.00 6" SW INV: 897.33 FES-02 15" NE INV: 897.00 900 905899901 902903904900 899 901 902 903 900 89 9 9 0 1 9 05 902 90 3 904900 897 898 899 901 902 9008 9 6 8 9 7 8 9 8 8 9 9 900899900899900899 901902900 8978988 9 9 9008988999 0 1 9 0 0 8988 9 9 900900900 901 90 190190 1 901 9 0 1 901 901902 90190 1 900 900 8 9 8 900901A B D 4" PVC F E FIBER OPTIC BY OTHERS AS MARKED UP ON SITE PREP PLANS TERMINATE CONDUIT FOR FUTURE VEHICLE COUNTER WITH ELECTRICAL HANDHOLE F E CS-02 RIM: 902.05 12" NE INV: 897.00 6" E INV: 897.00 12" S INV: 897.00 CB-03 RIM: 901.00 6" NE INV: 899.50 FES-04 12" SW INV: 897.16 6" NW INV: 898.50 6" S INV: 898.50 CO-3 RIM: 900.00 6" N INV: 898.50 6" SW INV: 898.50 END 6 6" INV: 898.47 FES-01 15" SW INV: 897.50 CO-5 RIM: 899.00 6" NE INV: 897.33 6" W INV: 897.33 CS-01 RIM: 899.09 12" N INV: 896.00 EXIS. 15" S INV. 895.48 +/- FES-05 12" N INV: 896.12 56 LF - 15" CL IV RCP @ 0.90%27 LF - 12" RCP @ 0.59%207 LF - 12" RCP @ 0.42%74 LF - 6" @ 0.00% 38 LF - 6" PVC @ 0.08%94 LF - 6" @ 0.00%131 LF - 6" @ 0 . 2 5 % 20 LF - 6" PVC @ 1.00% 43 LF - 6" PVC @ 0.46% CB-04 RIM: 898.41 15" W INV: 896.46 91 LF - 15" RCP @ 0.50% FES-06 15" INV: 896.00 3,5 CU501 FES-03 12" INV: 896.00 1 CU501 END 4 6" INV: 899.50 END 3 6" INV: 899.50 END 5 6" INV: 899.50 3,5 CU501 10" TRENCH DRAIN TD-5 12 LF @ 8.33% REFER TO GRADING PLAN FOR RIM ELEVATIONS E INV: 898.3 W INV: 898.2 4" GATE VALVE. CONNECT TO EXIS. 4" SERVICE. 3 CS505 1,2,3 CU500 1,2,3 CU500 1,2,3 CU500 1,2,3 CU500 1,2,3 CU500 GATE VALVE BOX GATE VALVE VAULT FIRE HYDRANT ASSEMBLY SANITARY MANHOLE CLEANOUT STORM STRUCTURE CURB INLET CATCH BASIN FLARED END SECTION HANDHOLE REPAIR STRUCTURE WATER MAIN SANITARY SEWER FORCE MAIN STORM SEWER UNDERDRAIN DRAINAGE SWALE ELECTRICAL LINE UNDERGROUND FIBER-OPTIC LINE UNDERGROUND EXISTING WATER MAIN EXISTING SANITARY SEWER EXISTING STORM SEWER w W S UTILITY CROSSING CALLOUT D co WATER EDGE ELEVATION: 895.40' JANUARY 2, 2020 LIMITS OF CONSTRUCTION WETLAND MITIGATION SITE BOUNDARY EXISTING WETLAND UTILITY PLAN 11640 CU101 LEGEND N KEYED NOTES SEALS AND SIGNATURES KEY PLAN DRAWING TITLE PROJECT NUMBER SCALE DRAWING NUMBER DATEREVISSUED FOR 500 PARK BOULEVARD SUITE 800 ITASCA, IL 60143 630.221.1212 www.williams-architects.com WEST PARK: THE CORE 2700 W. 116TH STREET CARMEL, IN 46032 Owner: 44 EAST MIFFLIN STREET SUITE 500 MADISON, WI 53703 608.251.1177 www.smithgroup.com ISSUED FOR CONSTRUCTION 09/10/2020 MATCHLINE CU102MATCHLINE CU103 0'80'40'20' SCALE: 1" = 40' CONNECT WATER MAIN INTO EXISTING STUB INTO THE BUILDING 2" PVC CONDUITS FOR FUTURE SECURITY CAMERAS, CAP ENDS INSIDE RESTROOM MECHANICAL ROOM (101) AND ON NORTHWEST FACE OF PICNIC SHELTER COLUMNS CONNECT PIPE INTO EXISTING STRUCTURE RELOCATE ELECTRICAL SERVICE PROVIDE 2" PVC CONDUIT FOR FUTURE FIBER-OPTIC EXTENSION TO RESTROOM. CONNECT SOUTH END TO HANDHOLE INSTALLED BY OTHERS, TAKING CARE NOT TO DISTURB SPOOLED FIBER CABLE INSIDE. CAP NORTH END INSIDE RESTROOM MECHANICAL ROOM (101) AT LOCATION DESIGNATED OWNER. CONDUIT MAY EITHER BE DIRECTIONAL DRILLED OR OPEN TRENCHED AT CONTRACTOR'S DISCRETION. IF OPEN TRENCHED, ALL DISTURBED PAVEMENT AREAS MUST BE REPAIRED IN-KIND TO OWNER'S SATISFACTION. PROVIDE 2" PVC CONDUIT FOR FUTURE VEHICLE COUNTER. CAP NORTH END INSIDE RESTROOM MECHANICAL ROOM (101) AT LOCATION DESIGNATED BY OWNER. PROVIDE ELECTRICAL HANDHOLE AT SOUTH END. CONDUIT MAY EITHER BE DIRECTIONAL DRILLED OR OPEN TRENCHED PER KEY NOTE E. A B C D E F PER CITY STORMWATER RVW 09/21/2020 PER CITY STORMWATER RVW 10/16/2020