HomeMy WebLinkAboutCU103 UTILITY PLANco co D co D w co co D D co co DD D EG-MH-02 EG-CO-01 REPAIR EXISTING SANITARY MANHOLE 2 CU501 RETROFIT TO TYPE II CLEANOUT 5 CU500 4 CU500 4 CU500 900 899 901 902 903 901 901902 90290190 1 910909911905910 902 903 904 906 907908909911912913 901905903904906 907 90 8 900901900901 901A B C C D 4" PVC 20" TRENCH DRAIN TD-2 REFER TO GRADING PLAN FOR RIM ELEVATIONS 110 LF @0.4% N INV: 901.44 S INV: 901.00 8" TRENCH DRAIN TD-4 24 LF @6.17% REFER TO GRADING PLAN FOR RIM ELEVATIONS N INV: 901.18 S INV: 899.70 8" TRENCH DRAIN TD-3 24 LF @5.67% REFER TO GRADING PLAN FOR RIM ELEVATIONS N INV: 901.06 S INV: 899.70 F E CB-01 RIM: 900.09 CB-03 RIM: 901.00 6" NE INV: 899.50 CO-2 RIM: 900.00 6" NW INV: 898.50 6" S INV: 898.50 CO-3 RIM: 900.00 6" N INV: 898.50 6" SW INV: 898.50 END 6 6" INV: 898.47 74 LF - 6" @ 0.00% 38 LF - 6" PVC @ 0.08% 287 LF - 8" PVC @ 0.13% 20 LF - 6" PVC @ 1.00% 43 LF - 6" PVC @ 0.46% 36 LF - 6" @ 2.43% CO-1 RIM: 901.10 6" SE INV: 899.37 CO-6 RIM: 913.79 6" N INV: 909.92 34 LF - 6" PVC UD @ 1.20% 4 CU500 4 CU50097 LF - 6" PVC @ 2.00 % 128 LF - 6" PVC @ 0.78% CONNECT 6" RETAINING WALL UD TO TRENCH GRATE 10 LF 6" PVC INV: 901.60 (AT UD CONNCTION) INV: 901.50 (AT TRENCH GRATE CONNECTION) 6" RUD INV: 901.60 6" RUD INV: 902.50 6" RUD INV: 903.00 6" RUD INV: 903.50 6" RUD INV: 903.30 6" RUD INV: 903.00 6" RUD INV: 903.50 RETAINING WALL UNDERDRAIN (RUD): 50 LF - 6" UD @ 0.5% MIN 6" RUD INV: 908.50 902END 2 6" INV: 908.27 6" INV: 909.51 CO-7 RIM: 911.23 6" SE INV: 910.21 6" NE INV: 910.21 CO-8 RIM: 912.98 6" SW INV: 911.96 3,5 CU501 4 CU500 4 CU500 RETAINING WALL UNDERDRAIN (RUD): 135 LF - 6" UD @ 0.5% MIN 6" RUD INV: 911.0 43 LF - 6" UD @ 2.61% 12 LF - 6" UD @ 3.94% 10 LF - 6" UD @ 1.50% 6" END 1 6" INV: 902.00 END 4 6" INV: 899.50 END 3 6" INV: 899.50 END 5 6" INV: 899.50 3,5 CU501 30" TRENCH DRAIN TD-1 REFER TO GRADING PLAN FOR RIM ELEVATIONS 15 LF @0.4% N INV: 901.50, SW INV 901.44 3 CS505 3 CS505 3 CS505 3 CS505 1B EX CB1 EX CB2 GATE VALVE BOX GATE VALVE VAULT FIRE HYDRANT ASSEMBLY SANITARY MANHOLE CLEANOUT STORM STRUCTURE CURB INLET CATCH BASIN FLARED END SECTION HANDHOLE REPAIR STRUCTURE WATER MAIN SANITARY SEWER FORCE MAIN STORM SEWER UNDERDRAIN DRAINAGE SWALE ELECTRICAL LINE UNDERGROUND FIBER-OPTIC LINE UNDERGROUND EXISTING WATER MAIN EXISTING SANITARY SEWER EXISTING STORM SEWER w W S UTILITY CROSSING CALLOUT D co WATER EDGE ELEVATION: 895.40' JANUARY 2, 2020 LIMITS OF CONSTRUCTION WETLAND MITIGATION SITE BOUNDARY EXISTING WETLAND UTILITY PLAN 11640 CU103 LEGEND N KEYED NOTES SEALS AND SIGNATURES KEY PLAN DRAWING TITLE PROJECT NUMBER SCALE DRAWING NUMBER DATEREVISSUED FOR 500 PARK BOULEVARD SUITE 800 ITASCA, IL 60143 630.221.1212 www.williams-architects.com WEST PARK: THE CORE 2700 W. 116TH STREET CARMEL, IN 46032 Owner: 44 EAST MIFFLIN STREET SUITE 500 MADISON, WI 53703 608.251.1177 www.smithgroup.com ISSUED FOR CONSTRUCTION 09/10/2020MATCHLINE CU102MATCHLINE CU101 0'80'40'20' SCALE: 1" = 40' CONNECT WATER MAIN INTO EXISTING STUB INTO THE BUILDING 2" PVC CONDUITS FOR FUTURE SECURITY CAMERAS, CAP ENDS INSIDE RESTROOM MECHANICAL ROOM (101) AND ON NORTHWEST FACE OF PICNIC SHELTER COLUMNS CONNECT PIPE INTO EXISTING STRUCTURE RELOCATE ELECTRICALSERVICE PROVIDE 2" PVC CONDUIT FOR FUTURE FIBER-OPTIC EXTENSION TO RESTROOM. CONNECT SOUTH END TO HANDHOLE INSTALLED BY OTHERS, TAKING CARE NOT TO DISTURB SPOOLED FIBER CABLE INSIDE. CAP NORTH END INSIDE RESTROOM MECHANICAL ROOM (101) AT LOCATION DESIGNATED OWNER. CONDUIT MAY EITHER BE DIRECTIONAL DRILLED OR OPEN TRENCHED AT CONTRACTOR'S DISCRETION. IF OPEN TRENCHED, ALL DISTURBED PAVEMENT AREAS MUST BE REPAIRED IN-KIND TO OWNER'S SATISFACTION. PROVIDE 2" PVC CONDUIT FOR FUTURE VEHICLE COUNTER. CAP NORTH END INSIDE RESTROOM MECHANICAL ROOM (101) AT LOCATION DESIGNATED BY OWNER. PROVIDE ELECTRICAL HANDHOLE AT SOUTH END. CONDUIT MAY EITHER BE DIRECTIONAL DRILLED OR OPEN TRENCHED PER KEY NOTE E. ALL UNDERDRAIN (UD) PIPING SHALL BE WRAPPED WITH UNDRDRAIN GEOXTILE UNLES OTHERWISE NOTED. SEE SHEET PS1.1- SITE PLUMBING PLAN FOR CONTINUATION OF WATER LINE INTO SPLASH PAD CONNECT PIPE TO ALL EXISTING DRAINTILE CONNECTIONS IT CROSSES A B C D E F G H I H I H PER CITY STORMWATER RVW 09/21/2020 PER CITY STORMWATER RVW 10/16/2020