Loading...
HomeMy WebLinkAboutALB13 Roof Truss Placement Plan49- HUS26 HANGERS: LD1LD1 LD2 LD2 LD3LD3 K01 K02A01A02A02A02A02A02A02 A02A02A02A03A03A04A04A04A04A04A04A05C01C02C02C02C02C02C02C02C02C02B01B01B01B01B01B01B01B01B01B01B02E01E01E01E01E01E01E01E01E01E01E02D01D01D01D01D01D01D01D01D01D01D02L01 L02 L02 L02 L02 L02 L03 L03 L04 W01 W01 P01P02P02P02P02P02P02P02P02P02P02P01V01 V02 V03 V04 V05 V06 V07 V08 V09 V10 V11 V12 V13 V14PB01PB02PB02PB02PB02PB02PB02PB02PB02PB02PB02PB02PB02PB02PB02 PB02PB02PB02PB03A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A 5-08-12 35-03-08 18-03-0059-03-045-08-12 2-00-003-00-00 8-00-00 22-03-08 18-03-0059-03-0422-02-08 14-00-00 21-08-08 57-11-00 19-06-08 17-10-00 20-06-08 57-11-00 48-06-08IMPORTANT THIS DRAWING IS FOR FIELD PLACEMENT OF INDIVIDUAL COMPONENTS ONLY,AND DOES NOT CONSTITUTE AN ENGINEERED DOCUMENT. NOTE PROPER BEARING ANDBEARING DESIGN INCLUDING ANCHORAGE,IS THE RESPONSIBILITY OF THE BUILDING DESIGNER,ARCHITECT AND /OR BUILDING ENGINEER. REFER TO INDIVIDUAL TRUSS DESIGNS FOR REACTIONS,MINIMUM REQUIRED BEARING SIZE,UPLIFT,AND ADDITIONAL LOADS. 84 COMPONENTS DOES NOT ASSUME RESPONSIBILITY IN THESE AREAS OF CONCERN. BRACING ERECTION,TEMPORARY,AND PERMANENT BRACING IS THE RESPONSIBILITY OF THE CONTRACTOR AND /OR BUILDING DESIGNER. REFER TO INDIVIDUAL TRUSS DESIGNS FOR ADDITIONAL BRACING REQUIREMENTS. REFER TO BCSI-B1 SUMMARY SHEET. THE STRUCTURAL BUILDING COMPONENTS ASSOCIATION COMMENTARY,AND RECOMMENDATIONS FOR HANDLING,INSTALLING &BRACING METAL PLATE CONNECTED WOOD TRUSSES. www.sbcindustry.com INSTALLATION DO NOT CUT,DRILL,OR ALTER TRUSSES. ANY QUESTIONS CALL 84 COMPONENTS. PROPER INSTALLATION,AND HANDLING OF COMPONENTS IS THE RESPONSIBILITY OF THE ERECTING CONTRACTOR. 84 COMPONENTS MUST BE NOTIFIED OF ANY PROBLEMS,AND AFFORDED THE OPPORTUNITY TO REVIEW,AND MAKE NECESSARY CORRECTIONS,OR NO BACK CHARGES WILL BE ACCEPTED ORAPPROVED. WARNING WARNINGS,AND INSTRUCTIONS FOR ERECTION OF COMPONENTS ARE INCLUDED IN THE DELIVERY PACKAGE. KEEP THIS INFORMATION ON THE JOB SITE. THESE DOCUMENTS WILL ALSO BE NEEDED FOR JOB SITE INSPECTION. MISUSE AND IMPROPER INSTALLATION OF COMPONENTS MAY RESULT IN FAILURE,BODILY INJURY,LOSS OF PROPERTY,AND /OR LIFE. RoofArea: Overhang Length: Eave Length: HipLength: ValleyLength: Ridge Length: SHEETNUMBER: R1.1 RoofTruss Placement Plan SCALE: NTS Job#: PO#: Date: 2/5/2020 Drawn By: KLD Designed By: KLD Checked By: ROOF LOADS: TCLL: 20.0 lb/ft² TCDL: 10.0 lb/ft² BCLL: 0.0 lb/ft² BCDL:10.0 lb/ft² Building Code: IBC 2012 Wind Speed: 90 mph On-Center Spacing: 24" U.N.O. 3977.09SF 142.94 LF 317.01 LF 0 LF 117.55 LF 119.76 LF ROOF DATA THIS LAYOUTIS INTENDED FOR THE PURPOSE OF TRUSS LOCATION AND PLACEMENTONLY. REFER TO THE BUILDINGPLANS FOR ACTUAL BUILDINGCONSTRUCTION.MOTICELLO A BASE, ,ROOF TRUSS PLACEMENTPLANOffice:Fax:12/03/20