HomeMy WebLinkAboutALB13 Roof Truss Placement Plan49- HUS26 HANGERS:
LD1LD1
LD2 LD2
LD3LD3
K01
K02A01A02A02A02A02A02A02 A02A02A02A03A03A04A04A04A04A04A04A05C01C02C02C02C02C02C02C02C02C02B01B01B01B01B01B01B01B01B01B01B02E01E01E01E01E01E01E01E01E01E01E02D01D01D01D01D01D01D01D01D01D01D02L01
L02
L02
L02
L02
L02
L03
L03
L04
W01
W01
P01P02P02P02P02P02P02P02P02P02P02P01V01
V02
V03
V04
V05
V06
V07
V08
V09
V10
V11
V12
V13
V14PB01PB02PB02PB02PB02PB02PB02PB02PB02PB02PB02PB02PB02PB02PB02 PB02PB02PB02PB03A A A A A A A A A A A
A A A A A A A A A
A A A A A A A A A
A A A A A A A A A A
A A A A A A A A A A
A
5-08-12 35-03-08 18-03-0059-03-045-08-12 2-00-003-00-00 8-00-00 22-03-08 18-03-0059-03-0422-02-08 14-00-00 21-08-08
57-11-00
19-06-08 17-10-00 20-06-08
57-11-00
48-06-08IMPORTANT
THIS DRAWING IS FOR FIELD PLACEMENT OF INDIVIDUAL
COMPONENTS ONLY,AND DOES NOT CONSTITUTE AN
ENGINEERED DOCUMENT.
NOTE
PROPER BEARING ANDBEARING DESIGN INCLUDING
ANCHORAGE,IS THE RESPONSIBILITY OF THE BUILDING
DESIGNER,ARCHITECT AND /OR BUILDING ENGINEER. REFER
TO INDIVIDUAL TRUSS DESIGNS FOR REACTIONS,MINIMUM
REQUIRED BEARING SIZE,UPLIFT,AND ADDITIONAL LOADS.
84 COMPONENTS DOES NOT ASSUME RESPONSIBILITY IN
THESE AREAS OF CONCERN.
BRACING
ERECTION,TEMPORARY,AND PERMANENT BRACING IS THE
RESPONSIBILITY OF THE CONTRACTOR AND /OR BUILDING
DESIGNER. REFER TO INDIVIDUAL TRUSS DESIGNS FOR
ADDITIONAL BRACING REQUIREMENTS. REFER TO BCSI-B1
SUMMARY SHEET. THE STRUCTURAL BUILDING COMPONENTS
ASSOCIATION COMMENTARY,AND RECOMMENDATIONS FOR
HANDLING,INSTALLING &BRACING METAL PLATE CONNECTED
WOOD TRUSSES. www.sbcindustry.com
INSTALLATION
DO NOT CUT,DRILL,OR ALTER TRUSSES. ANY QUESTIONS
CALL 84 COMPONENTS. PROPER INSTALLATION,AND
HANDLING OF COMPONENTS IS THE RESPONSIBILITY OF THE
ERECTING CONTRACTOR. 84 COMPONENTS MUST BE
NOTIFIED OF ANY PROBLEMS,AND AFFORDED THE
OPPORTUNITY TO REVIEW,AND MAKE NECESSARY
CORRECTIONS,OR NO BACK CHARGES WILL BE ACCEPTED
ORAPPROVED.
WARNING
WARNINGS,AND INSTRUCTIONS FOR ERECTION
OF COMPONENTS ARE INCLUDED IN THE DELIVERY PACKAGE.
KEEP THIS INFORMATION ON THE JOB SITE. THESE
DOCUMENTS WILL ALSO BE NEEDED FOR JOB SITE
INSPECTION. MISUSE AND IMPROPER INSTALLATION OF
COMPONENTS MAY RESULT IN FAILURE,BODILY INJURY,LOSS
OF PROPERTY,AND /OR LIFE.
RoofArea:
Overhang Length:
Eave Length:
HipLength:
ValleyLength:
Ridge Length:
SHEETNUMBER:
R1.1
RoofTruss
Placement Plan
SCALE: NTS
Job#:
PO#:
Date: 2/5/2020
Drawn By: KLD
Designed By: KLD
Checked By:
ROOF LOADS:
TCLL: 20.0 lb/ft²
TCDL: 10.0 lb/ft²
BCLL: 0.0 lb/ft²
BCDL:10.0 lb/ft²
Building Code: IBC 2012
Wind Speed: 90 mph
On-Center Spacing: 24" U.N.O.
3977.09SF
142.94 LF
317.01 LF
0 LF
117.55 LF
119.76 LF
ROOF DATA
THIS LAYOUTIS INTENDED FOR THE PURPOSE OF TRUSS LOCATION AND PLACEMENTONLY. REFER TO THE BUILDINGPLANS FOR ACTUAL BUILDINGCONSTRUCTION.MOTICELLO A BASE, ,ROOF TRUSS PLACEMENTPLANOffice:Fax:12/03/20