HomeMy WebLinkAboutALB13 S100.1 First Floor StructualLATERAL BRACING & SHEAR WALL SHEATHING SPECIFICATIONS THIS MODEL HAS BEEN DESIGNED TO RESIST LATERAL FORCES RESULTING FROM: 115 MPH WIND IN 2020 InRC MAP (115 MPH WIND SPEED IN ASCE 7-16 WIND MAP, PER IRC R301.2.1.1) EXP. B, RISK CAT. 2 & SEISMIC CAT. A/B. THE DESIGN WAS COMPLETED PER 2018 IBC (SECTION 1609) & ASCE 7-16, AS PERMITTED BY R301.1.3 OF THE 2020 InRC, OR THE SIMPLIFIED PRESCRIPTIVE PROCEDURE IN ACCORDANCE WITH THE 2020 InRC IF THE PARAMETERS OFSECTION R602.12 COMPLY. ACCORDINGLY, THISMODEL, AS DOCUMENTED AND DETAILED HEREWITHIN, IS ADEQUATE TO RESIST THE CODE REQUIRED LATERAL FORCES. SEE CONNECTION SPECIFICATIONS CHART FOR STANDARD SHEAR TRANSFER DETAILING. IFADDITIONAL CAPACITY IS REQUIRED BY DESIGN, IT WILL BE SPECIFICALLY NOTED ON PLAN. ALL STRUCTURAL PANELS ARE TO BE DIRECTLY APPLIED TO STUD FRAMING. NOTES M&K STND. - OCT. 2015 PRE-MANUFACTURED PANELIZED WALLS: FASTEN TOGETHER END STUDS OF WALL PANELSSHEATHED w/ OSB OR PLYWOOD w/ 10d NAILS @ 4" O.C. (THRU ONE SIDE ONLY) 3" O.C. EDGE NAILING 7/16" OSB OR 15/32" PLYWOOD: FASTEN SHEATHING w/ 2-3/8"x0.113 NAILS @ 6" O.C. AT EDGES & @ 12" O.C. IN THE PANEL FIELD. (TYP, U.N.O.) ALL SHEATHING PANELS SHALL BE ORIENTEDVERTICALLY (LONG DIRECTION PARALLEL TO STUDS) AND INSTALLED FULL HEIGHT OF SHEAR WALL - OR -2x HORIZONTAL BLOCKING SHALL BE PROVIDED TO SUPPORT ALL UNSUPPORTED PANEL EDGES & EDGEFASTENING. EXT. WALL SHEATHING SPECIFICATION ALL EXT. WALLS SHALL BE CONTINUOUSLY SHEATHED AND ARE CONSIDERED SHEAR WALLS. ALT. STAPLE CONNECTION SPEC: 1-3/4" 16 GA STAPLES (7/16" CROWN) @ 3" O.C. AT EDGES & @ 6"O.C IN FIELD. AT DESIGNATED AREAS - FASTEN PANEL EDGES OFWOOD STRUCTURAL WALL SHEATHING TO FRAMING w/ 2-3/8"x0.113" NAILS @ 3" o.c. AND 12" o.c. IN THEPANEL FIELD. NO STAPLE ALTERNATIVE AVAILABLE AT THIS SPEC. ALL SHEATHING PANELS SHALL BEORIENTED VERTICALLY (LONG DIRECTION PARALLEL TO STUD) AND INSTALLED FULL HEIGHT OF SHEARWALL - OR - 2x HORIZONTAL BLOCKING SHALL BE PROVIDED TO SUPPORT UNSUPPORTED PANEL EDGESAND 3" O.C. EDGE FASTENING. DESIGN ASSUMES 16" O.C MAX. STUD SPACING, U.N.O. INDICATES HOLDOWN INDICATES EXTENT OF INT. OSB SHEARWALL AND/OR 3" O.C. EDGE NAILING INDICATES POST ABOVE (P.A.) PROVIDE SOLID BLOCKING UNDER POST OR JAMBABOVE. ã COLUMN TOP PLATE BOLTED TO BEAM WITH AT LEAST (4) 12" DIAMETER BOLTS BOTTOM FLANGE OF STEEL BEAM FASTENED TO SUPPORTING WOOD FRAMING w/ (2) 12" DIA. X 3 12" LONG LAG SCREWS. CLIP ANGLES EITHER WELDED TO THE BEAM ALONG EACH CLIP ANGLE'S ENTIRE LENGTH OR BOLTED TO THE BEAM USING A MINIMUM OF 12" DIAMETER BOLTS. CLIP ANGLE ATTACHED TO THE FOUNDATION WALL USING NO LESS THAN (1) 12" DIAMETER ANCHOR OR (2) 14" DIA. x 214" LONG TAPCON SCREWS. BEAM POCKET GROUTED SOLID AROUND STEEL BEAM STEEL BM SUPPORTED ON WOOD FRAME STEEL BEAM IN BEAM POCKET ANCHORED TO CONCRETE FOOTING PAD WITH (2) 12" DIAMETER CONC. ANCHORS THROUGH THE STEEL BASE PLATE TO THE CONCRETE FOUNDATION. ANCHORED TO CONCRETE FOOTING PAD WITH (4) 12" DIAMETER CONC. ANCHORSTHROUGH THE STEEL BASE PLATE TO THE CONCRETE FOUNDATION. ENCASED IN CONCRETE SLAB STEEL CONNECTIONS CHART CONNECTION SPECIFICATION CAP COLUMN TOP PLATE EITHER WELDED ALONG THE TWO SIDES PERPENDICULAR TO THE BEAM'S LENGTH OR BOLTED WITH (2) 1#2" DIAMETER BOLTS PLACED DIAGONALLY THROUGH THE TOP PLATE CONNECTION TYPE TO STL. COLUMN (INTERIOR CONDITION) BASE OR TO STL. COLUMN (END CONDITION) CAP BASE ENCASED IN CONCRETE SLAB OR OR REISSUED: 10/07/2020 12/03/20