Loading...
HomeMy WebLinkAboutLandscape Plan_Stamped Approved 12-03-20PROPOSED 50' DRAIN& UTILITY EASEMENTPROPOSED 50' DRAINAGE& UTILITY EASEMENTPE-7 PE-5 PE-5 PE-7 PE-11 PE-11 146290 SF FIELDHOUSE 107 391 SF CORRIDOR108 149 SF ELECTRICAL112 315 SF WOMEN109 73 SF RESTROOM110 319 SF MEN111 PE-1 PE-2 PE-1 PE-1 PE-1 PE-1 PE-1 209 SF CORRIDOR101 235 SF TICKETS102 78 SF STORAGE103 59 SF RESTROOM104 463 SF VESTIBULE100 PE-4 W82 W82 433 SF MEETING106337 SF TRAINING105 2633 SF STORAGE114 71 SF MEZZANINE ACCESS115 PE-1 PE-2 PE-1 PE-1 PE-1PE-1 PE-1 PE-1 PE-2 PE-1 PE-1 PE-1 PE-1 PE-1 PE-1 PE-2 PE-1 PE-1 PE-1PE-1 PE-1 FUTURE SOCCER FIELD 7 7 1 1 1 1 1 1 1 2 3 3 33 3 3 3 4 10 66 2 3 3 2 2 3 3 3 6 6 3 3 3 9 8 10 4 10 6 6 6 6 6 1 222 2 9 8 8 1 3 1 1 3 3 1 1 3 8 10 4 10 10 3 3 9 7 3 GENERAL NOTES 1. SEE SHEET G0.1 FOR GENERAL NOTES, LEGEND AND ABBREVIATIONS. 2. REFER TO SURVEY SHEET FOR BOUNDARY AND TOPOGRAPHIC SURVEY INFORMATION. KEYNOTES 4" DEEP SHREDDED HARDWOOD MULCH LANDSCAPE BED PER SPECIFICATIONS 4" DEEP WASHED RIVER ROCK BED - PER DETAIL F/L1.3 SEEDED LAWN PER SPECIFICATIONS SEED WITH DETENTION BASIN SEED MIX - SEE PLANT SCHEDULE FOR REQUIREMENTS TREE RING - PER DETAIL A/L1.3 PROTECT EXISTING TREE TO REMAIN (TREE PROTECTION FENCE TO FOLLOW TREE LINE) - PER DETAIL C/L1.3 ASPHALT PATH - SEE DETAIL R/ G6.1 TRENCH BED EDGE - PER DETAIL E/L1.3 STEEL EDGING - PER DETAIL G/L1.3 SEED WITH SLOPE STABILIZATION SEED MIX ON SIDE SLOPE - SEE PLANT SCHEDULE FOR REQUIREMENTS 1 2 3 4 5 6 7 8 9 10 Know what'sbelow. before you dig.Call R Call 811 or 1-800-382-5544 Before You Begin Any Digging Project. Call 48 hours or 2 working days before you dig. It's Fast, It's Easy and It's the Law in the state of Indiana! INLETS, VALVES, AND MARKS MADE UPON THE GROUND BY ALSO BE OTHER EXISTING UNDERGROUND UTILITIES FOR WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR EXACT LOCATIONS OF EXISTING UNDERGROUND UTILITIES SHALL BE VERIFIED BY CONTRACTOR PRIOR TO ANY AND WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE OTHERS) AND ARE SPECULATIVE IN NATURE. THERE MAY ALL CONSTRUCTION. THE LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES EVIDENCE (INCLUDING, BUT NOT LIMITED TO, MANHOLES, SHOWN ON THE PLAN ARE BASED UPON ABOVE GROUND CAUTION !! LANDSCAPE PLAN SCALE: 1"= 30'N 30 900 30 60 LEGEND EXISTING TREE DECIDUOUS TREE EVERGREEN TREE ORNAMENTAL TREE SHRUB SEEDED LAWN SEEDED DETENTION BASIN PLANTINGS SLOPE STABILIZATION PLANTINGS WASHED RIVER ROCK BED TREE PROTECTION FENCE NEW BUILDING BUILD LIMIT LINE - EDGE OF TREELINE AND SLOPE PLANNORTHN WS ECOPYRIGHT 2019 BY FANNING/HOWEY ASSOCIATES, INC. WWW.FHAI.COM ARCHITECT CONSULTANT PROJECT NUMBER: 2019199.00 INDOOR FACILITY AT BADGER FIELDS CLAY TOWNSHIP 5459 E MAIN STREET CARMEL, INDIANA PROJECT ISSUE DATE: 06.08.2020 DRAWN BY: MTP REV. NO. DESCRIPTION DATE 11300453 SOI STATE OF ORPFE S NEER N LA E N G IANAINIDERDAHC IIGS No. TERE DA C NIK.N DCONSTRUCTION DOCUMENTS PROJECT MANAGER: CNK ADDENDUM #1 6/25/2020 ADDENDUM #2 7/1/2020 ADDENDUM #3 7/8/2020 COC REVISIONS 10/5/2020 LANDSCAPE PLAN - SOUTH L1.2 10 JCK 2 LSR 6 JCK 2 UAV 2 QB 8 RAG MATCH LINE - SEE SHEET L1.1 2 UAV 2 QB 2 LSR 12 JCK 2 RAG 12 JCK 10 JCK 10 JCK 12 RAG 12 RAG 12 RAG 9 RAG 13 RAG FINAL CONSTRUCTION PLANS Indoor Facility at Badger Fields 20-Oct-2020 12/03/20 Daren Mindham TREE PLANTING DETAIL SHRUB PLANTING DETAIL TRENCH EDGE SCALE : 1" = 6" NO SCALE NO SCALE A L1.3 B L1.3 E L1.3 H L1.3SCALE: 3/4" = 1'-0" BICYCLE PARKING RACK PLAN VIEW SECTION G.1 TOOLED CONTROL JOINT 1/2" EXPANSION JOINT TOOLED CONTROL JOINT TOOLED CONTROL JOINT CONCRETE SIDEWALK TREE PRESERVATION DETAIL NO SCALE C L1.3 1/2" EXPANSION JOINT WITH SEALANT CONCRETE SIDEWALK #4 DOWELS X 1'-4" LONG @ 2'-0" O.C. STAINLESS STEEL ANCHORS 2" Ø INVERTED U-TYPE BIKE RACK WITH BLACK THERMOPLASTIC POWDER COATING MODEL : SU 20-F-T AS MANUFACTURED BY CREATIVE PIPE INC. (800)644-8467 OR APPROVED EQUAL G.1 L1.2 4" 4" DO NOT BREAK ROOTBALL. 1. ROTOTILL TO 12" DEPTH. SPREAD 4" MIN. LAYER OF PLANTING SOIL MIX OVER BED. NOTE: ROTOTILL SOIL MIX INTO TOP OF BED. INSTALL PLANTS AND MULCH. WATER THROUGHLY. LIRIODENDRON TULIPIFERA SHRUBS LT QUANTITY TREES ABBR. BOTANICAL NAME TULIP TREE SIZE COMMON NAME NOTESROOT B&B SPACING JCK JUNIPERUS CHINENSES 'KALLAY'S COMPACT' KALLAY PFITZER JUNIPER AS SHOWN CONT. #3 2 1/2" RAG RHUS AROMATICA 'GRO-LOW' GROW LOW SUMAC B&B AS SHOWN CONT. QUERCUS BICOLOR QB 2 1/2" SWAMP WHITE OAK B&B 2 1/2" B&B AS SHOWN DENSE BRANCHING, MATCHED2 1/2" DENSE BRANCHING, MATCHED DENSE BRANCHING, MATCHED DENSE BRANCHING, MATCHED #3 24" HEIGHT & 18" WIDTH MIN., 24" HEIGHT & 24" WIDTH MIN. EVERGREEN TREES PO PICEA OMORIKA 6' HT. SERBIAN SPRUCE B&B AS SHOWN DENSE BRANCHING, MATCHED15 25 8 60 4 4 ORNAMENTAL TREES AGA AMELANCHIER X GRANDIFLORA 'AUTUMN BRILLIANCE' AUTUMN BRILLIANCE SERVICEBERRY B&B AS SHOWN DENSE, MULTI-STEM6 6' HT. AS SHOWN 68 PA PICEA ABIES 6' HT. NORWAY SPRUCE B&B AS SHOWN DENSE BRANCHING, MATCHED10 NOTES: 1. TRENCH EDGE SHALL CREATE A CLEAN SEPARATION BETWEEN MULCHED PLANTING BEDS & LAWN AREAS. THE EDGE SHALL CREATE A SMOOTH AND EVEN LINE AS SHOWN ON PLANS. 2. PLACE SOIL FROM TRENCH EDGE WITHIN BED. 3. TRENCH BED EDGE SHALL BE USED AT THE EDGES OF ALL MULCHED PLANTING BEDS THAT ABUT LAWN AREAS FOR CONTAINMENT. VERTICAL EDGE 4" SHREDDED HARDWOOD MULCH FINISH GRADE OF PLANTING BED MULCHED PLANTING BEDLAWN AREA 3"4"4" WASHED RIVER ROCK REFER TO PLOT & LANDSCAPE PLANS FOR LOCATIONS GEOTEXTILE SOIL SEPARATOR COMPACTED SUBGRADE NOTES: 1. STEEL EDGING TO BE INSTALLED BETWEEN ALL WASHED RIVER ROCK BEDS AND LAWN AREAS. NOTES: 1. STEEL EDGING COLOR TO BE GREEN. 2. STEEL EDGING TO BE INSTALLED BETWEEN ALL WASHED RIVER ROCK BEDS AND LAWN AREAS. 3. STEEL EDGING TO BE INSTALLED FLUSH WITH ADJACENT FINISHED GRADE. FINISH GRADE 4" WASHED RIVER ROCK GEOTEXTILE SOIL SEPARATOR COMPACTED SUBGRADE 1/4" STEEL EDGING, PAINTED GREEN 1'-3" LONG TAPERED STEEL STAKES SPACED @ 2'-6"5"10" NOTES: 1. DO NOT ALLOW AIR POCKETS TO FORM WHEN BACKFILLING. 2. IMMEDIATELY SOAK WITH WATER. 3. DO NOT USE PLANTS WITH BROKEN OR CRACKED ROOTBALL. 4. PERENNIALS OF THE SAME SPECIES SHALL BE MATCHED IN GROWTH CHARACTER AND UNIFORMITY. 5. IF HEAVY CLAY OR A RESTRICTIVE HARD PAN IS ENCOUNTERED AUGER 6" DIAMETER DRAINAGE HOLES,2'-0"APART, INTO FREE-DRAINING STRATA OR TO A DEPTH OF 10' WHICHEVER IS LESS TO PROVIDE FOR GOOD DRAINAGE. 4" SHREDDED HARDWOOD MULCH UNDISTURBED SUBGRADE PLAN ROTOTILL TO 1'-6" DEPTH, SPREAD 2" LAYER OF HUMUS, ROTOTILL HUMUS INTO TOP 8" OF BED REMOVE CONTAINER & DISPOSE OF OFF SITE PERENNIAL PERENNIALS SHALL BE PLANTED USING A TRIANGULAR PLANTING SCHEME. REFER TO THE PLANTING SCHEDULE FOR THE ON-CENTER PLANTING DIMENSION. EQUALEQUALLIQUIDAMBAR STYRACIFLUA 'ROTUNDILOBA' LSR ROTUNDILOBA SWEETGUM 4 ULMUS AMERICANA 'VALLEY FORGE' UAV 'VALLEY FORGE' ELM VB VIBURNUM X BURKWOODII BURKWOOD VIBURNUM 30" HEIGHT & 24" WIDTH MIN., PERENNIAL PLANTING SCALE : 3/4" = 1'-0" D L1.3 WASHED RIVER ROCK BED SCALE : 1" = 6" F L1.3 STEEL EDGING SCALE : 1" = 6" G L1.3 HPT HYDRANGEA PANICULATA 'TARDIVA' LATE PANICLE HYDRANGEA 25 30" HEIGHT & 24" WIDTH MIN.,B&B 30" B&B30" AS SHOWN BASIN SEED MIX DETENTION BASIN SEED MIX SEED WITH EQUAL PARTS STORMWATER SEED MIX AND ECONOMY PRAIRIE SEED MIX AT A RATE OF 35 PLS POUNDS PER ACRE. AS SHOWN AS SHOWN AS SHOWN SLOPE STABILIZATION SEED MIX SEED WITH SLOPE STABILIZATION SEED MIX AT A RATE OF 60 PLS POUNDS PER ACRE. ADD 1 4 ACRE OF NATIVE WILDFLOWER SEED MIX TO 1 ACRE OF THE SLOPE STABILIZATION SEED MIX. REFER TO EROSION CONTROL PLAN FOR REQUIRED EROSION CONTROL BLANKET. SEED MIXES AVAILABLE FROM: CARDNO NATIVE PLANT NURSERY (OR APPROVED EQUAL) 128 WALKERTON, INDIANA 574-586-2412 INSTALL SEED MIX PER CARDNO INSTALLATION AND MAINTENANCE GUIDELINES. TRENCH EDGE TRENCH EDGE SLOPE STABILIZATION SEED MIX NATIVE WILDFLOWER SEED MIX STORMWATER SEED MIX ECONOMY PRAIRIE SEED MIX COPYRIGHT 2019 BY FANNING/HOWEY ASSOCIATES, INC. WWW.FHAI.COM ARCHITECT CONSULTANT PROJECT NUMBER: 2019199.00 INDOOR FACILITY AT BADGER FIELDS CLAY TOWNSHIP 5459 E MAIN STREET CARMEL, INDIANA PROJECT ISSUE DATE: 06.08.2020 DRAWN BY: MTP REV. NO. DESCRIPTION DATE CONSTRUCTION DOCUMENTS PROJECT MANAGER: CNK ADDENDUM #1 6/25/2020 ADDENDUM #2 7/1/2020 ADDENDUM #3 7/8/2020 COC REVISIONS 10/5/2020 LANDSCAPE DETAILS L1.3 INLETS, VALVES, AND MARKS MADE UPON THE GROUND BY ALSO BE OTHER EXISTING UNDERGROUND UTILITIES FOR WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR EXACT LOCATIONS OF EXISTING UNDERGROUND UTILITIES SHALL BE VERIFIED BY CONTRACTOR PRIOR TO ANY AND WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE OTHERS) AND ARE SPECULATIVE IN NATURE. THERE MAY ALL CONSTRUCTION. THE LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES EVIDENCE (INCLUDING, BUT NOT LIMITED TO, MANHOLES, SHOWN ON THE PLAN ARE BASED UPON ABOVE GROUND CAUTION !! Know what'sbelow. before you dig.Call R Call 811 or 1-800-382-5544 Before You Begin Any Digging Project. Call 48 hours or 2 working days before you dig. It's Fast, It's Easy and It's the Law in the state of Indiana! 11300453 SOI STATE OF ORPFE S NEERN LA E N G IANAINIDERDAHC IIGS No. TERE DA C NIK.N DFINAL CONSTRUCTION PLANS Indoor Facility at Badger Fields 20-Oct-2020 12/03/20 Daren Mindham GENERAL NOTES 1. SEE SHEET G0.1 FOR GENERAL NOTES, LEGEND AND ABBREVIATIONS. 2. REFER TO SURVEY SHEET FOR BOUNDARY AND TOPOGRAPHIC SURVEY INFORMATION. KEYNOTES 4" DEEP SHREDDED HARDWOOD MULCH LANDSCAPE BED PER SPECIFICATIONS 4" DEEP WASHED RIVER ROCK BED - PER DETAIL F/L1.3 SEEDED LAWN PER SPECIFICATIONS SEED WITH DETENTION BASIN SEED MIX - SEE PLANT SCHEDULE FOR REQUIREMENTS TREE RING - PER DETAIL A/L1.3 PROTECT EXISTING TREE TO REMAIN (TREE PROTECTION FENCE TO FOLLOW TREE LINE) - PER DETAIL C/L1.3 ASPHALT PATH - SEE DETAIL R/ G6.1 TRENCH BED EDGE - PER DETAIL E/L1.3 STEEL EDGING - PER DETAIL G/L1.3 SEED WITH SLOPE STABILIZATION SEED MIX ON SIDE SLOPE - SEE PLANT SCHEDULE FOR REQUIREMENTS 1 2 3 4 5 6 7 8 9 10 Know what'sbelow. before you dig.Call R Call 811 or 1-800-382-5544 Before You Begin Any Digging Project. Call 48 hours or 2 working days before you dig. It's Fast, It's Easy and It's the Law in the state of Indiana! INLETS, VALVES, AND MARKS MADE UPON THE GROUND BY ALSO BE OTHER EXISTING UNDERGROUND UTILITIES FOR WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR EXACT LOCATIONS OF EXISTING UNDERGROUND UTILITIES SHALL BE VERIFIED BY CONTRACTOR PRIOR TO ANY AND WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE OTHERS) AND ARE SPECULATIVE IN NATURE. THERE MAY ALL CONSTRUCTION. THE LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES EVIDENCE (INCLUDING, BUT NOT LIMITED TO, MANHOLES, SHOWN ON THE PLAN ARE BASED UPON ABOVE GROUND CAUTION !! LANDSCAPE PLAN SCALE: 1"= 30'N 30 900 30 60 LEGEND EXISTING TREE DECIDUOUS TREE EVERGREEN TREE ORNAMENTAL TREE SHRUB SEEDED LAWN SEEDED DETENTION BASIN PLANTINGS SLOPE STABILIZATION PLANTINGS WASHED RIVER ROCK BED TREE PROTECTION FENCE 4PROPOSED 50' DRAINAGE& UTILITY EASEMENTPROPOSED 50' DRAINAGE& UTILITY EASEMENTTYP TYP TYP TYP 7 7 7 7 5 5 5 3 3 3 8 8 8 8 1 1 1 1 5 6 6 6 3 3 3 3 3 6 6 8 1 PLANNORTHN WS ECOPYRIGHT 2019 BY FANNING/HOWEY ASSOCIATES, INC. WWW.FHAI.COM ARCHITECT CONSULTANT PROJECT NUMBER: 2019199.00 INDOOR FACILITY AT BADGER FIELDS CLAY TOWNSHIP 5459 E MAIN STREET CARMEL, INDIANA PROJECT ISSUE DATE: 06.08.2020 DRAWN BY: MTP REV. NO. DESCRIPTION DATE 11300453 SOI STATE OF ORPFE S NEER N LA E N G IANAINI DERDAHC IIGS No. TERED A C NIK.N DCONSTRUCTION DOCUMENTS PROJECT MANAGER: CNK ADDENDUM #1 6/25/2020 ADDENDUM #2 7/1/2020 ADDENDUM #3 7/8/2020 COC REVISIONS 10/5/2020 PER CONTRACTOR 11/11/2020 RFI 009 11/20/2020 LANDSCAPE PLAN - NORTH L1.1 5 VB 5 HPT 5 VB 3 AGA 3 AGA 5 PA 5 VB 5 PA 5 PA 5 PO 5 VB 5 PO 5 VB 2 LT2 LT 2 LT 2 LT MAIN STREET MATCH LINE - SEE SHEET L1.2 5 HPT 5 HPT 5 HPT 5 HPT 12/03/20 Daren Mindham