Loading...
HomeMy WebLinkAboutA000.3PLOTTED: October 27, 2020 / Kamlesh Bisht / 2596-IN-GENEVA-ET01.DWG A3-ET01 1FB.3English Tudor2 Car Side EntryFront, Side and Rear Elevations, Roof Plan and Ventilation ScheduleIndiana Division11590 North Meridian Street, Suite 530Carmel, Indiana 46032........................... PLAN NAME SHEET PRODUCTION MANAGER DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN ID GARAGE HANDING REV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS INITIAL RELEASE DATE:CURRENT RELEASE DATE: (c) Copyright Pulte Home Corporation - 2020 Zach Bittner3/30/2015 GARAGE LEFT 2596-Geneva 1836.0000 LOT 22 10/27/2020 \A1;4'-0"+12"+ 6"\A1;9'-0" + 0"2030 FX2030 FX2030 FX\A1;R5'-9{\H0.750000x;\S1#4;}"4:12 6:12 \A1;16'-9{\H0.750000x;\S1#2;}" 8:12 \A1;R7'-1{\H0.750000x;\S1#4;}" \A1;7'-6" \A1;2'-1"\A1;2'-1"\A1;3'-1" \A1;8'-1{\H0.750000x;\S1#8;}"\A1;9'-1{\H0.750000x;\S1#8;}" \A1;8'-11{\H0.750000x;\S1#2;}" TOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF FOUNDATION SOLDIER COURSE, PER SPEC 18"x72" SHUTTERS, PER SPEC ROOF SHINGLES, PER SPEC 8" FASCIA, PER SPEC10" FRIEZE, PER SPEC 4" CORNER BOARD, PER SPECHORIZONTAL SIDING, PER SPEC 1x3 OVER 8" RAKE BOARD, PER SPEC4" FRIEZE, PER SPEC BRICK VENEER, PER SPEC 1214 1214 1214 1214 FYPON# LV12X36 OR APPROVED EQUAL SCALE:FRONT ELEVATION1/4" = 1'-0"- FYPON# LV12X36 OR APPROVED EQUAL FYPON BRACKET #DTLB6X6X5 OR APPROVED EQUAL 6" BATTENS @ 18" O.C. O/ HARDIE PANEL (SMOOTH) 4" FRIEZE, PER SPEC 6" TRIM BD., PER SPEC 8" TRIM BD., PER SPEC 6" ROUGH TIMBER TRIM BD., PER SPEC4" FRIEZE, PER SPECSTONE CORBEL, PER SPEC BLACKOUT WINDOW, TYP.\A1;4'-0" + 6"+8.5" +8.5"+ 6"\A1;9'-0" \A1;5'-6"+ 0"+ 0" STONE SILL, PER SPEC \pxql;PROVIDE ADEQUATE OPENING FOR AIR MOVEMENT BETWEEN ATTIC SPACES TO SUPPORT REQUIRED VENTILATION, TYP. "A"3459ROOF AREA:SQ. FT. 14:1214:12 14:12 \A1;16'-0" \A1;26'-0" 6:12 4:1214:1214:12 \A1;6'-0" 14:12 \pxql;PROVIDE ADEQUATE OPENING FOR AIR MOVEMENT BETWEEN ATTIC SPACES TO SUPPORT REQUIRED VENTILATION, TYP.14:1214:12 8:12 14:12 14:12 14:12 8:128:12 8:128:12 8:128:12 6:12 SCALE:ROOF PLAN1/8" = 1'-0"- ROOF SHINGLES, PER SPEC 1x3 OVER 8" FASCIA, PER SPEC10" FRIEZE, PER SPEC 4" CORNER BOARD, PER SPECHORIZONTAL SIDING, PER SPECMASONRY WRAP, PER SPEC TOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF FOUNDATION TOP OF FOOTING \A1;8'-1{\H0.750000x;\S1#8;}"\A1;9'-1{\H0.750000x;\S1#8;}" \A1;8'-7{\H0.750000x;\S1#2;}"\A1;3'-6" SCALE:LEFT ELEVATION1/8" = 1'-0"- 128 128 128 126 STONE VENEER, PER SPECSTONE SILL, PER SPECBRICK VENEER, PER SPEC 4" FRIEZE, PER SPEC10" FRIEZE, PER SPEC \A1;3'-6"\A1;MIN. 126 128 SCALE:RIGHT ELEVATION1/8" = 1'-0"- 126128 126 ROOF SHINGLES, PER SPEC8" FASCIA, PER SPEC4" FRIEZE, PER SPEC STONE SOLDIER COURSE, PER SPECSTONE VENEER, PER SPEC\A1;8'-1{\H0.750000x;\S1#8;}"\A1;9'-1{\H0.750000x;\S1#8;}" \A1;8'-7{\H0.750000x;\S1#2;}" TOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF FOUNDATION\A1;3'-6"\A1;MIN. 124 TOP OF FOOTING \A1;3'-6" MASONRY WRAP, PER SPEC4" CORNER BOARD, PER SPEC 8" FASCIA, PER SPEC10" FRIEZE, PER SPEC \A1;9'-0"\A1;WINDOW HEAD HT.\A1;11'-1{\H0.750000x;\S1#8;}"\A1;PLATE HT. SCALE:REAR ELEVATION1/8" = 1'-0"- TOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF FOUNDATION 4" CORNER BOARD, PER SPEC 8" FASCIA, PER SPECROOF SHINGLES, PER SPEC 121412146:12 TOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF FOUNDATION TOP OF SLAB MASONRY WRAP, PER SPEC4" CORNER BOARD, PER SPEC 8" FASCIA, PER SPECROOF SHINGLES, PER SPEC \A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-1{\H0.7x;\S1#8;}" \A1;2'-0" \A1;8'-7{\H0.750000x;\S1#2;}"\A1;6'-8"\A1;3'-6" ELEVATION ET01 ATTIC VENT SCHEDULE VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS * SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION ROOF AREA "A"SQ FTG 3459 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POTVENTS ONLY 4.61 5.77 5.93 51.02 14 0 AT EAVE 6.92 5.77 5.69 48.98 0 82.00 TOTAL (MIN)11.53 11.53 11.63 100.00 3 HIGH - RIDGE VENT 4.61 5.77 6.00 51.92 0 0 48.00 AT EAVE 6.92 5.77 5.56 48.08 0 80.00 TOTAL (MIN)11.53 11.53 11.56 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE 11/24/20