ALB24 S001.0 Foundation Plans
17'-2"9'-8 1/2" TO C.L. OF COLUMN 8'-9" TO C.L. OF COLUMN 8'-8" TO C.L. OF COLUMN 8'-5 1/2" UNEXCAVATED 17'-8"16'-4" 14'-0" 4'-0"2'-0" W8x18 STEEL BEAMTO BEAM C.L.11'-10"W8x15 STEEL BEAM 4 3 5 2 D1.1 11'-0" 9'-9 1/2" 2 (TYP.) (TYP.)TO BEAM C.L. 18'-11" TO BEAM C.L. 17'-8 1/4"TO BEAM C.L.19'-11 3/4"11 11 1 4'-4" 10'-2"6'-4" 9'-4 1/2" 9 15'-8"8 20'-1"FULL BASEMENT UNEXCAVATED 55 TO DRAIN C.L.3'-2 1/2"TO DRAIN C.L. 2'-11" 11'-4 1/4"1'-4" 2'-7 1/2" 1'-4" 19'-3 3/4"2'-11" 25'-10 1/2"CJ12 4" 10'-0 1/2" 11'-1" 48'-0"53'-6"3'-1" 9'-0" 1'-4" 16'-0" 24'-1"1'-8" 7'-10" 11'-10" 44'-0" 1'-8" 31'-3"7 7 6 15'-0" 8 9 17'-0" UNEXCAVATED 12'-0 3/4" 12'-2"65'-8"65'-8"5'-4" 1'-0"12'-2"7'-11" 5'-3" 10 ISLAND ABOVE DBL EVERY OTHER JOISTS UNDER ADD'L JOIST(UNDER CABINETS ABOVE)(1)1-3/4"x14" LVL(FLUSH)(1)1-3/4"x14" LVL (FLUSH) B.W.A. B.W.A. B.W.A. B.W.A. 14 (CONTINUOUS) 7'-0" 7'-0" 4040 SLIDER 15 17 FIREPLACE ABOVE RESIDENCE FOR:Sheet InformationHouse Name: Series: Plan No.: Job Number: Drawing Date: Coord Name: Coord Phone: Drawing Scale: 1/8" = 1'0" Contract Drawn By: ( ) The Drees Company. All Rights Reserved. Space for Architect Seal 900 East 96th Street, Suite 100, Indianapolis, IN 46240 Phone: [317] 347-7300 Born on Date: CDs Drawn By: Copyright © AMANKELDI 3558 MARSDALE COURT ALBANY PLACE ALB-0024-00 10/15/2020 MPH 1.01 Elevation "U" Foundation Plan 859-578-4290 the BUCHANAN EWT 08/27/2010 SSP 2010 2019 Key Notes: 1 OUTLINE OF BASEMENT STAIRS SLAB CONTROL JOINT SLAB CONTROL JOINT LOCATED DIRECTLY UNDER STEEL BEAM STEEL COLUMN PER MANUFACTURER (16.4K MAX) ON 36"x36"x12" CONCRETE PAD GARAGE SLAB TO BE HELD A MINIMUM OF 4" BELOW TOP OF FOUNDATION AND IS TO SLOPE 1/4" PER FOOT TOWARDS GARAGE DOOR 2 3 4 5 6 7 CONTINUOUS FOOTING AND FOUNDATION; DROP TO BE FIELD DETERMINED 8 9 10 1-1/2" TYP. OVERHANG AT CONCRETE PORCH SLAB ABOVE 11 12 13 14 15 BRICK LEDGE -FIELD VERIFY DROPPED BRICK LOCATIONS 16 8"W. x 8"H. x 4"D. BEAM POCKET General Notes: 1. REFER TO SHEET 0N.1 FOR GENERAL NOTES. 2. ALL FOUNDATION WALLS TO BE 9'-0" TALL AND 8" THICK UNLESS OTHERWISE NOTED. 3. OVERALL FOUNDATION WALL HEIGHT MAY VARY UP TO 1". 4. SEE SHEET 0N.1 FOR VERTICAL FOUNDATION WALL CONTROL JOINT LOCATIONS. 5'0" DIA. AREA SLOPED TO DRAIN; 2" LOWER THAN TOP OF SLAB LINE OF STUD WALL/PORCH SLAB ABOVE -SEE DETAIL D/7.01 FOR MORE INFORMATION 8”DEEP x 16”WIDE FOOTING AT BEARING WALL 17 REFER TO SHEET S-1A, S-1B, S-1C, S-1D -AS NEEDED FOR GARAGE PILASTER DETAIL CONCRETE HEADER STEEL COLUMN PER MANUFACTURER (16.4K MAX) ON 24"x24"x12" PLAIN CONCRETE PAD BOTTOM OF WINDOW SILL 44" MAX ABOVE FINISHED FLOOR 11/25/20