Loading...
HomeMy WebLinkAboutC203 Amenity Area Plans-C20342' * * * * * EX. 5' SIDEWAL K EX . 5' SID E W A LK EX. 5' SI DEWALK EX. 5' SIDEW A L K N.P.= 10 YEAR ELEV.= 2 YEAR ELEV.= 100 YEAR ELEV.= BOTTOM ELEV.= EX. WET POND WITH NATIVE BANKS 833.00 835.63 837.14 839.57 817.00 6 BI CY CL E PA R K I N G SP A C E S @ 2.5'x6' 29. 8'25'25'5.3'32.7'43'36. 7' 8' 8' 8' 6.5'8'8' 8'3.1'15.6'POOL (1,050 sq.ft.)BATHHOUSEPICNIC AREA MULCH PLAYGROUND AREA BI KE SHA R E EASE M E NT CONNECT TO EXISTING SIDEWALK FFE844.05' SIDEWALK× EX. WATER SERVICE LINE C.O. 83 8 5' SIDEWALK 5' SIDEWALK5' SIDEWALK 0 +0 0 0 +2 2 438A 22 L.F. 12 " HDPE @ 1.00% 11.7 ' EX. CURB INLET #438 T.C.=841.94 12" R.C.P. S INV.=835.50 14.7'14.7'1.5 ' 1.5 ' 42. 2 ' 25'42.7'9' 6.3'6.3' EX. 4' MH #801A T.C.=843.48 8" S.D.R. 35 P.V.C NW INV.=830.95 8" S.D.R. 35 P.V.C E INV.=830.85 54.5' 9.4 '17.9'30 . 7 ' 32.3' 30.4' 58. 2 ' EX. 4' MH #802 T.C.=843.09 8" S.D.R. 35 P.V.C NW INV.=831.40 8" S.D.R. 35 P.V.C SE INV.=831.30 8" S.D.R. 26 P.V.C NE INV.=831.50 EX. 4' MH #803 T.C.=843.26 8" S.D.R. 35 P.V.C SW INV.=832.09 8" S.D.R. 35 P.V.C SE INV.=831.89 4.1'A A D C CB B E EX. CURB INLET #441 T.C.=843.53 18" R.C.P. NE INV.=838.37 15" R.C.P. S INV.=838.47 EX. 4' MH #804 T.C.=843.84 8" S.D.R. 26 P.V.C W INV.=832.48 8" S.D.R. 35 P.V.C NE INV.=832.38 8" S.D.R. 35 P.V.C S INV.=832.48 EX. 4' MH #804 (2) T.C.=844.14 8" S.D.R. 35 P.V.C N INV.=832.74 EX. YARD INLET #481 T.C.=844.61 15" R.C.P. N INV.=839.00 EX. CURB INLET #439 T.C.=842.10 12" R.C.P. NE INV.=837.84 EX. CURB INLET #440 T.C.=842.16 12" R.C.P. SW INV.=837.55 12" R.C.P. NE INV.=837.45 EX. CURB INLET #436 T.C.=843.06 42" R.C.P. E INV.=835.32 42" R.C.P. NW INV.=835.42 12" R.C.P. N INV.=836.46 EX. CURB INLET #440C T.C.=842.49 12" R.C.P. NE INV.=837.04 EX. CURB INLET #429 T.C.=843.04 18" R.C.P. NE INV.=837.22 18" R.C.P. SW INV.=837.32 EX. CURB INLET #437 T.C.=842.68 42" R.C.P. W INV.=835.04 42" R.C.P. E INV.=834.94 EX. CURB INLET #440A T.C.=842.95 18" R.C.P. SW INV.=838.10 18" R.C.P. NE INV.=838.00 DATE MARK REVISIONS BYCERTIFIED: S & A JOB NO. SHEET NO. DRAWN BY: CHECKED BY:THIS DRAWING IS NOT INTENDED TO BEREPRESENTED AS A RETRACEMENT ORORIGINAL BOUNDARY SURVEY, A ROUTESURVEY OR A SURVEYOR LOCATIONREPORT.S T O E P P E L W E R T HA L W A Y S O N7965 East 106th Street, Fishers, IN 46038-2505phone: 317.849.5935 fax: 317.849.5942AMENITY AREA - SITE PLANC203 1" = 20 FT 65840BKM-Sec 2-3-4SECTIONS 2, 3, & 4ADG JSL CLAY TOWNSHIP HAMILTON COUNTY, INDIANA03/20/2019DP I T E S G E E O TS R P RTE WLE D EHVADI R J .ADNINAI EEG NIRENOILA NSFEPROSTATE OF S File Name: S:\65840BKM-S3\DWG\C203 Amenity Area Plans.dwg - C203Modified / By: September 29, 2020 10:04:51 AM / dmetzPlotted / By: October 6, 2020 8:55:10 AM / Andre GuyonGRAMERCY WESTREVISED PER TAC COMMENTS ADG05/08/19 REVISED PER TAC COMMENTS ADG09/27/19 REVISED PER CLIENT COMMENTS DSM10/16/19 REVISED PER CITY OF CARMEL COMMENTS DSM12/12/19 REVISED PER CITY OF CARMEL COMMENTS DSM12/30/19 REVISED PER CLIENT COMMENTS DSM01/13/20 REVISED SWALE PER CARMEL COMMENTS DSM04/16/20 RAISED SITE 0.80 FT FOR DIRT BALANCE ADG09/24/20 LEGEND EXISTING CONTOUR EXISTING SANITARY SEWER EXISTING STORM SEWER PROPOSED GRADE PROPOSED CONTOUR PROPOSED SANITARY SEWER PROPOSED STORM SEWER PROPOSED WATER LINE PROPOSED SWALE PROPOSED 5' SIDEWALK (BY HOME BUILDER) (DEVELOPER SHALL INSTALL SIDEWALKS ALONG ALL COMMON AREAS) Ù ADA RAMP TO BE INSTALLED 870 S 848.0 870 W > o o o KEY NOTES 5' CONCRETE SIDEWALK POOL FENCE (SEE DETAIL ON SHEET C804) SAFETY FENCE (SEE DETAIL ON SHEET 804) RETAINING WALL (SEE DETAIL ON SHEET 804) STREET LIGHT (SEE DETAIL BELOW) A B C D E GENERAL NOTES: 1. ALL SSD (SUBSURFACE DRAINS) WILL NEED TO BE 6" DOUBLE WALL SMOOTH BORE PERFORATED (HDPE) PIPE. UNLESS OTHERWISE NOTED. 2. ALL EXISTING OFF-SITE DRAIN TILES THAT ARE ENCOUNTERED SHALL BE TIED INTO THE PROPOSED STORM SEWER SYSTEM WITH A POSITIVE OUTFLOW. ANY TILE THAT IS ENCOUNTERED THAT IS COMPLETELY ON-SITE MUST BE CRUSHED AND ABANDONED. 3. ALL PADS SHALL BE TESTED TO ASSURE A COMPACTION OF AT LEAST 95 PERCENT OF THE MAXIMUM DRY DENSITY USING THE STANDARD PROCTOR TEST METHOD. 4. CONTRACTOR SHALL VERIFY LOCATION AND DEPTH OF ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION TO CONFIRM THERE ARE NO CROSSING CONFLICTS. CONFLICTS THAT ARE DISCOVERED AFTER CONSTRUCTION BEGINS ARE SOLELY THE CONTRACTOR'S RESPONSIBILITY. 5. UTILITY CROSSINGS UNDER PAVEMENT (BORE/JACK & BORE). AVOID OPEN CUTS. UTILITY CROSSINGS CONTRACTOR SHALL VERIFY LOCATION AND DEPTH OF ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION TO CONFIRM THERE ARE NO CROSSING CONFLICTS. CONFLICTS THAT ARE DISCOVERED AFTER CONSTRUCTION BEGINS ARE SOLELY THE CONTRACTOR'S RESPONSIBILITY. AMENITY BATHHOUSE 1698 SQ. FT. CONCRETE POOL DECK 2155 SQ. FT. AMENITY POOL 1050 SQ. FT. 5' CONCRETE WALK 150 L.F. 12/04/20