Loading...
HomeMy WebLinkAboutC700 Water Plan-C700SA3 N RI M MM M MMGolfview DriveAPARTMENT BUILDINGAPARTMENT BUILDING84784884 3 84 2 84684784784884884984984 9 8498 3 5 83 1 83 2 83 3 83 4 83 6 83 7 83 8 8 3 9 8 2 5 83 0 8 2 4 8 2 6 8 2 7 8 2 8 8 2 9 83 1 82282 3 836840838835834840847 847 849 849 830.70SA3 N RI M SA3 N RI M 3780 838.53 ST2 S FLAT SA3 N RI M 5139 841.93 5140 841.90 A/C_UNIT C.O. SA4 R4 EX. SANITARY MANHOLE TC=831.85' EX. SANITARY MANHOLE TC=839.22' 10" CLAY INV.=833.32' SW 20' Gas Line Easement Record 264, Pg. 354 Amended by Record 301, Pg. 645 (NOT TO BE VACATED) 2 0' 2 0' 20'20'20' Gas Line Easement Record 264, Pg. 354 Amended by Record 301, Pg. 645 MOHAWK WB LLC MOHAWK WB LLC * * * * * * * * * 8 2 0 82 1 8 1 7 8 1 8 8 1 98 4 0 8 4 1 8 4 2 8" TEE 8" TEE 22.5° BEND 11.25° BEND 8" VALVE 8" VALVE 8" VALVE TEMP. HYDRANT TEMP. HYDRANT 8" VALVE 8" D . I.8" D.I.HYDRANT 8" VALVE TEMP. HYDRANT 11.25° BEND 8" TEE 8" D.I. 8" VALVE 84 0 83 7 83 8 83 9 841 842 83 5 83 2 83 3 83 4 83 6 83 0 828 82 9 83 1 826 827 825 824 822 823820821 817818 819 8 4 2 842843844APARTMENT BUILDINGAP A R T M E N T BU I L D I N G 1867 839.40 X LINE 18"? RCP 1868 845.45 X LINE 18"? RCP PVMT PVMT PVMT Gol fvi ew Dr i ve Kinzer AvenueKinzer AvenueEX. 5' SIDEWAL K EX. 5' SID E W A L K E X. 5' S I DEWALK EX . 5' SID EW A L K EX. SANITARY MANHOLE TC=833.41' 8" CLAY INV.=826.41' S 10" CLAY INV.=826.29' W INV.=825.96' N INV.= 824.24' E N.P.= 10 YEAR ELEV.= 2 YEAR ELEV.= 100 YEAR ELEV.= BOTTOM ELEV.= EX. WET POND WITH NATIVE BANKS 833.00 835.63 837.14 839.57 817.00 SA3 N RIM10' BIKE LANESTEINBECK PLACE (Private)ASTOR LANE(Private)VALENTINE DRIVE(Private)VALE NTINE DRI VE(Private)21' I.E.E. 31' D.U.&S.S.E.31 ' D.U.&S.S.E.31' D.U.&S.S.E.21' I.E.E.21' I.E.E. 2 1 ' I.E.E.21' I.E.E.VAR. D.U.& L.M.A.E.&P.A.E. VAR. D.U.& L.M.A.E.&P.A.E. & B.M.P.E. VAR. D.U.& L.M.A.E.&P.A.E. VAR. D.U.& L.M.A.E.& P.A.E.KINZERAVENUE(Public)5' B.L.5' BL5' BL 5' BL 1 4 ' B.L.5' BL31 ' D.U.&S.S.E.VAR. D.U.& L.M.A.E.&P.A.E.& B.M.P.E. 10' P.A.E.10' P.A.E. 10' P.A.E. 10' P.A.E.5' D.&U.E. 5' D.&U.E. 10' D.&.U.E. 10' D.&.U.E.15' D.&.U.E. 15' D.&.U.E. 15' D.&.U.E. 15' D.&.U.E.5' BL5' B L 5' BL 5' BL 5' BL 5' BL 5' BL 5' BL 5' BL 5' BL 5' BL5' BL 5' BL5' BL 5' BL5' BL5' BL 15' D.&.U.E.15' D.&.U.E. 15' D.&.U.E. 10' D.&.U.E.5.5' P.A.E.VA R . B .M.P.E. VAR. S.L.E.10'10'10'10' HYDRANT HYDRANT 11.25° BEND 11.25° BEND 11.25° BEND 11.25° BEND 22.5° BEND 22.5° BEND 8" TEE S 1" COPPER SERVICE LINE 140 24 L.F. 1" COPPER SERVICE LINE 88 26 L.F. 1" COPPER SERVICE LINE 87 26 L.F. 1" COPPER SERVICE LINE 86 24 L.F. 1" COPPER SERVICE LINE 85 24 L.F. 1" COPPER SERVICE LINE 84 26 L.F. 1" COPPER SERVICE LINE 83 25 L.F. 1" COPPER SERVICE LINE 82 24 L.F. 1" COPPER SERVICE LINE 81 24 L.F. 1" COPPER SERVICE LINE 80 24 L.F. 1" COPPER SERVICE LINE 79 25 L.F. 1" COPPER SERVICE LINE 89 4 L.F. 1" COPPER SERVICE LINE 90 3 L.F. 1" COPPER SERVICE LINE 91 3 L.F. 1" COPPER SERVICE LINE 92 3 L.F. 1" COPPER SERVICE LINE 93 4 L.F. 1" COPPER SERVICE LINE 94 3 L.F. 1" COPPER SERVICE LINE 78 24 L.F. 1" COPPER SERVICE LINE 77 24 L.F. 1" COPPER SERVICE LINE 76 24 L.F. 1" COPPER SERVICE LINE 75 24 L.F. 1" COPPER SERVICE LINE 74 24 L.F. 1" COPPER SERVICE LINE 73 24 L.F. 1" COPPER SERVICE LINE 72 24 L.F. 1" COPPER SERVICE LINE 71 24 L.F. 1" COPPER SERVICE LINE 70 24 L.F. 1" COPPER SERVICE LINE 95 3 L.F. 1" COPPER SERVICE LINE 97 3 L.F. 1" COPPER SERVICE LINE 96 3 L.F. 1" COPPER SERVICE LINE 98 3 L.F. 1" COPPER SERVICE LINE 99 3 L.F. 1" COPPER SERVICE LINE 100 3 L.F. 1" COPPER SERVICE LINE 139 24 L.F. 1" COPPER SERVICE LINE 138 24 L.F. 1" COPPER SERVICE LINE 137 24 L.F. 1" COPPER SERVICE LINE 136 24 L.F. 1" COPPER SERVICE LINE 101 3 L.F. 1" COPPER SERVICE LINE 102 3 L.F. 1" COPPER SERVICE LINE 103 3 L.F. 1" COPPER SERVICE LINE 104 3 L.F. 1" COPPER SERVICE LINE 105 3 L.F. 1" COPPER SERVICE LINE 106 3 L.F. 1" COPPER SERVICE LINE 107 3 L.F. 1" COPPER SERVICE LINE 108 3 L.F. 1" COPPER SERVICE LINE 109 3 L.F. 1" COPPER SERVICE LINE 110 3 L.F.1" COPPER SERVICE LINE 111 3 L.F. 1" COPPER SERVICE LINE 134 3 L.F. STEINBECK PLACE (Private)ASTOR LANE(Private)VALENTINE DRIVE(Private)VALENTINEDRIVE(Private)21' I.E.E. B-B 31' D.U.&S.S.E.31 ' D.U.&S.S.E.31' D.U.&S.S.E.21' I.E.E.B-B21' I.E.E. B-B 21 ' I .E.E. B-B 21' I.E.E.B-B W W W W W W W WWWW W W W WWWW WWWW W WWWW8" TAPPING SLEEVE & VALVE WET TAP 20' (TYP.)9'(TYP.)20' (TYP. )9 '(TY P . ) 20'(T YP.)9'(TYP.)8" VALVE 8" VALVE 8" VALVE 8" VALVE SECTION 3 SECTION 2 REMOVE EX. TEMP. HYDRANT 1" COPPER SERVICE LINE 135 3 L.F. EX. 8" WAT E RHYDRANTEXIST. FIRE HYDRANT TO BE REINSTALLED AS A PERMINANT FIRE HYDRANT PER CARMEL WATER SPECIFICATIONS EXIST. FIRE HYDRANT TO BE REINSTALLED AS A PERMINANT FIRE HYDRANT PER CARMEL WATER SPECIFICATIONS EXISTING TRANFORMERS TO BE RELOCATED DATE MARK REVISIONS BYCERTIFIED: S & A JOB NO. SHEET NO. DRAWN BY: CHECKED BY:THIS DRAWING IS NOT INTENDED TO BEREPRESENTED AS A RETRACEMENT ORORIGINAL BOUNDARY SURVEY, A ROUTESURVEY OR A SURVEYOR LOCATIONREPORT.S T O E P P E L W E R T HA L W A Y S O N7965 East 106th Street, Fishers, IN 46038-2505phone: 317.849.5935 fax: 317.849.5942WATER PLANC700REVISED PER CARMEL WATER 03/12/20DSM 1" = 50 FT NOTES: NO EARTH DISTURBING ACTIVITIES MAY TAKE PLACE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT. FOR INSTALLATION OF SANITARY AND WATER UNDER CITY STREETS AND COVER REQUIREMENTS, SEE THE TRENCH DETAIL ON SHEET C700. THERE ARE TO BE NO WATER VALVES OR MANHOLES WITHIN THE PAVEMENT, CURB, OR SIDEWALK WITH THE EXCEPTION OF CURB INLETS. ALL WATERMAIN SERVICE LINES TO TERMINATE 5 FEET BEHIND SIDEWALK AND MARKED WITH A 4" PVC PIPE WITH A PAINTED BLUE TOP. POSI-CAPS OR EQUIVALENT IS REQUIRED ON ALL WATER VALVE INSTALLATION AND MEGA LUGS MUST BE INSTALLED AT ALL MECHANICAL JOINTS. ALL DUCTILE IRON WATERMAINS SHALL BE BEDDED IN SAND, FROM THE BOTTOM OF THE TRENCH TO 12" ABOVE THE PIPE INSTALL WATERMAIN TRACER WIRE WITH ALL WATER MAINS LAID AND BLUE REFLECTOR TAPE MUST BE INSTALLED 12" TO 18" ABOVE ALL WATERMAINS LAID, ALL WATERMAINS SHALL BE DUCTILE IRON AND INSTALLED PER THE CITY OF CARMEL SPECIFICATIONS FULL DEPTH GRANULAR BACKFILL PER CITY STANDARDS SHALL BE PLACED FOR ALL STREET CROSSINGS FIRE HYDRANT MARKERS TO BE INSTALLED IN THE STREET PAVEMENT PERPENDICULAR TO THE FIRE HYDRANT. ONLY MUELLER HYDRANTS AND VALVES MAY BE USED. PRESSURE PIPE JOINT RESTRAINT TABLE LENGTH OF IPE TO BE RESTRAINED IN EACH DIRECTION FROM 1/4 OF BEND BASED ON 150 psi TEST PRESSURE DEGREE OF BEND 6" 8" 10" 12" 14" 16" 18" 20" 24" 30" 90°, TEES & PLUGS 27' 35' 42' 50' 58' 65' 73' 80' 95' 115' 45° 7' 9' 11' 13' 15' 17' 19' 21' 24' 29' 22 1 2° 3' 4' 5' 6' 7' 8' 9' 10' 12' 14' 11 1 4° 2' 2' 3' 3' 4' 4' 4' 5' 6' 7' RESTRAINED JOINTS SHALL BE MECHANICAL JOINT WITH RETAINER GLANDS, US PIPE TR FLEX JOINT SYSTEM, US PIPE FIELD LOK GASKET SYSTEM. NOTE: THE ABOVE RESTRAINED JOINT LENGTHS ARE MINIMUM LENGTHS THE DESIGN ENGINEER SHALL DETERMINE IF LONGER LENGTHS ARE REQUIRED. LEGEND EXISTING FIRE HYDRANT EXISTING WATER VALVE EXISTING WATER METER PROPOSED FIRE HYDRANT PROPOSED WATER VALVE PROPOSED REDUCERDYHWV M 1" COPPER SERVICE LENGTH - EXCAVATE FOR EACH JOINT PIPE TO BE SUPPORTED ALONG ENTIRE WATER SERVICE INSTALLATION COCK 1" CORP. O.D. + 1' (NO SCALE)RIGHT-OF-WAY LINEPROTECTED ANGLE VALVE WITH PLASTIC WRAP 3.5' 1.0'5'-0" 65840BKM-Sec 2-3-4SECTIONS 2, 3, & 4ADG JSL CLAY TOWNSHIP HAMILTON COUNTY, INDIANA03/20/2019DP I T E S G E E O TS R P RTE WLE D EHVADI R J .ADNINAI EEG NIRENOILA NSFEPROSTATE OF S File Name: S:\65840BKM-S3\DWG\C700 Water Plan.dwg - C700Modified / By: March 12, 2020 11:18:34 AM / dmetzPlotted / By: October 6, 2020 9:20:05 AM / Andre GuyonGRAMERCY WESTREVISED PER TAC COMMENTS ADG05/08/19 REVISED PER TAC COMMENTS ADG09/27/19 REVISED PER CLIENT COMMENTS DSM10/16/19 REVISED PER CITY OF CARMEL COMMENTS DSM12/12/19 REVISED PER CITY OF CARMEL COMMENTS DSM12/30/19 REVISED PER CLIENT COMMENTS DSM01/13/20 REVISED SWALE PER CARMEL COMMENTSDSM04/16/20 RAISED SITE 0.80 FT FOR DIRT BALANCE ADG09/24/20 12/04/20