Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
E010 - SITE PHOTOMETRIC PLAN
ESL-Spectrum's services are for estimation purposes only, and are not warranties.Final design and illumination levels must be determined and specified by an electrical engineer.Field results may differ from computer predictions because of many uncontrollable factors and adverse test conditions such as:line voltage variations, lamp performance, product manufacturing tolerances, and jobsite conditions.THE FIXTURE TYPE(S) AND LAMPING(S) SPECIFIED ON THIS LAYOUT MUST BE USED IN ORDER TO MEET THE EXACT CRITERIA AND PERFORMANCE DATA SHOWN.PHOTOMETRIC PLAN DESIGNED BY ESL-SPECTRUMWWW.ESL-SPECTRUM.COMPHONE: 317.951.2300PROJECT NUMBER: 20200277-JHPROJECT NAME: STATE BANK CARMEL BRANCHDATE: 12-7-2020 SITE LIGHTING - PLAN VIEWScale: 1 inch= 12 Ft.TTVSACACEHEHTRSCVS1MH: 7S1MH: 7MH: 7S1MH: 7S1MH: 7S1F2MH: 0.5F2MH: 0.5MH: 7S1S1MH: 7H-24'MH: 17W1MH: 0F2MH: 0.5MH: 0.5F2F2MH: 0.5F2MH: 0.5F2MH: 0.5F2MH: 0.5MH: 13R2MH: 13R2MH: 13R2R2MH: 13MH: 13R2MH: 13R2V6MH: 20V6MH: 20V6MH: 200.9 5.5 9.1 7.0 1.2 0.2 0.2 0.4 0.5 0.6 0.80.1 0.1 0.2 0.4 0.6 1.1 4.8 7.7 6.1 1.3 0.4 0.4 0.7 1.0 1.1 1.40.1 0.2 0.4 6.3 4.7 7.1 3.1 3.8 5.8 5.9 0.4 0.6 1.0 1.3 1.6 1.80.1 0.30.8 1.2 1.5 2.1 2.60.2 0.40.1 0.1 0.1 0.6 4.1 6.3 5.0 0.8 0.2 0.1 0.1 0.10.1 0.1 0.1 0.2 0.31.1 1.3 1.5 2.2 2.80.2 0.41.2 1.2 1.4 1.8 2.00.2 0.30.9 1.1 1.3 1.3 1.60.2 0.40.9 0.9 1.0 1.0 1.30.3 0.5 1.0 1.7 3.0 4.7 5.7 4.8 2.9 1.5 1.1 1.0 1.0 0.9 0.8 0.70.3 0.7 1.2 1.7 2.2 2.7 2.8 2.4 1.6 1.1 1.2 1.3 1.3 1.3 1.1 0.90.2 0.8 1.3 1.7 2.0 2.1 2.0 1.6 1.1 0.9 1.2 1.5 1.6 1.50.3 0.9 1.3 2.6 2.6 2.0 1.4 1.0 0.9 1.3 1.8 2.3 2.40.3 1.2 1.7 3.2 3.0 2.1 1.8 1.2 1.2 1.7 2.0 2.8 3.00.1 0.5 0.60.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.6 0.8 0.7 0.2 0.1 0.1 0.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.0 0.0 0.10.1 0.1 0.1 0.0 0.0 0.0 0.0 0.00.0 0.0 0.00.7 0.0 0.0 0.0 0.0 0.00.0 0.0 0.11.4 0.0 0.0 0.0 0.0 0.00.0 0.0 0.11.7 0.1 0.0 0.0 0.0 0.00.0 0.0 0.1 0.90.3 2.6 0.2 0.1 0.0 0.0 0.00.0 0.1 0.1 0.82.3 2.7 0.3 0.1 0.0 0.0 0.00.0 0.1 0.1 1.12.5 1.8 0.1 0.1 0.0 0.0 0.00.0 0.0 0.1 0.71.3 1.4 0.1 0.0 0.0 0.0 0.00.0 0.1 0.1 0.7 2.2 5.7 11.0 14.0 11.6 6.3 2.3 1.1 1.1 0.1 0.1 0.00.0 0.00.0 0.1 0.10.4 0.1 0.1 0.0 0.0 0.00.0 0.1 0.10.5 0.2 0.0 0.0 0.0 0.00.0 0.0 0.11.4 1.1 0.6 0.1 0.0 0.0 0.0 0.00.0 0.0 0.1 2.01.8 1.2 0.7 0.2 0.0 0.0 0.0 0.00.0 0.0 0.1 2.22.0 1.6 1.1 0.2 0.0 0.0 0.0 0.00.0 0.0 0.0 0.6 1.0 0.9 0.6 0.7 0.4 0.5 0.9 1.0 1.3 1.4 0.9 0.8 0.60.1 0.0 0.0 0.0 0.00.0 0.0 0.0 0.0 0.1 0.1 0.1 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.20.1 0.1 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.1 0.10.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.025.5 25.525.6 24.921.0 21.015.3 16.49.7 10.75.6 5.92.7 3.61.3 1.80.8 1.20.7 1.326.1 26.724.9 25.00.40.50.20.10.10.10.10.20.20.10.20.10.00.00.00.10.10.10.10.20.20.10.10.10.10.10.10.10.00.00.00.00.00.10.10.31.01.61.40.30.10.10.10.00.00.00.00.00.00.00.10.10.20.30.20.40.80.40.60.91.21.41.72.52.50.5 fc1 fc0.25 fc0.1 fc0.5 fc1 fc0.25 fc0.1 fc1 fcPHOTOMETRIC PLAN DESIGNED BY ESL-SPECTRUMWWW.ESL-SPECTRUM.COMPHONE: 317.951.2300CALCULATIONS ARE MAINTAINED HORIZONTAL ILLUMINANCE FIGURES IN FOOT-CANDLESPOINTS SHOWN ARE AT GRADEFIXTURE MOUNTING HEIGHTS ARE SPECIFIED NEXT TO FIXTURES AS "MH"ESL-Spectrum's services are for estimation purposes only, and are not warranties.Final design and illumination levels must be determined and specified by an electrical engineer.Field results may differ from computer predictions because of many uncontrollable factors and adverse test conditions such as:line voltage variations, lamp performance, product manufacturing tolerances, jobsite conditions, and other unrecoverable light-loss factors.THE FIXTURE TYPE(S) AND LAMPING(S) SPECIFIED ON THIS LAYOUT MUST BE USED IN ORDER TO MEET THE EXACT CRITERIA AND PERFORMANCE DATA SHOWN.IES RECOMMENDED ILLUMINANCE TARGETS USED WHERE APPLICABLE.Luminaire ScheduleProject: 20200277-JH STATE BANK CARMEL BRANCH - SITE LIGHTINGSymbolCalculation SummaryProject: 20200277-JH STATE BANK CARMEL BRANCH - SITE LIGHTINGLabelQtyLabelArrangementLum. WattsLum. LumensCalcTypeUnitsAvgMaxMinAvg/MinLLFDescriptionMax/MinPARKING LOT & DRIVE @ GradeIlluminanceFc1.639.10.116.3091.00PERIMETER @ GradeIlluminanceFc0.3114.08F2SINGLE33.845300.8500.0N.A.N.A.RFL3-90L-40-4K7-WPROPERTY LINE @ GradeIlluminanceFc0.341H-24'GROUPN.A.N.A.0.880HP-4-WL-D-24ft-H-840-F6R2SINGLE17.214160.880SS4G4DSL3408 _ICS432HZ-PR7S1SINGLE3126710.850WO877-XX-LED3V6SINGLE82.3269990.850VP-S-36L-80-4K7-4-BC1W1SINGLE3747051.0000705332.50.0N.A.N.A.STAIRS BASE @ GradeIlluminanceFc25.6826.724.91.031.07STAIRS DOWN @ FloorIlluminanceFc11.0325.60.715.7636.57