Loading...
HomeMy WebLinkAboutS100.0 - First Floor MasterWIC.MATCH LINERIGHT SIDE LEFT SIDE K-3322-RAGABRIELLETOILETSVITREOUS CHINA K-3322-RAGABRIELLETOILETSVITREOUS CHINA K-3322-RAGABRIELLETOILETSVITREOUS CHINAK-3322-RAGABRIELLETOILETSVITREOUS CHINA POOL 24' X 24' FIRST FLOOR SQ. FT. 5,163 S.F. FINISHED LIVING 557 S.F. COVERED TERRACE 326 S.F. FRONT PORCH 986 S.F. OUTDOOR ENTERTAINING 1,675 S.F. GARAGE & CART LAUNDRY BUTLER'S PANTRY GEAR KITCHEN 4 - BAY GARAGE TRASH STORAGE / BIKES GATHERING DINING FOYER COVERED TERRACE OFFICE GUEST SUITE KING KING WIC. HIS HER'S MASTER SUITE LUGGAGE 8' X 8' SPAMATCH LINERIGHT SIDE LEFT SIDE OUTDOOR ENTERTAINING GRILLE PORCH WIC. 1 A-7.0 1 A-7.0 1 A-7.1 1 A-7.1 HALL COVERED PORCH 153 S.F. GRILLE PORCH 1 A-7.2 1 A-7.2 FOOD PANTRY STOR. PDR. 2020-0710 10-20-2020 Project No: Sheet Title REVISIONS Date: Sheet No.1806 Burning Tree LaneCarmel, IN 46032"FANCHER RESIDENCE"A New Residence for the:GARY NANCE DESIGN720 3rd Avenue South West Carmel, IN 46032317.605.2196 Pgnance@garynancedesign.com garynancedesign.comThese design concepts are the property of Gary Nance Designand may not be used without approval from Gary Nance DesignA R C H I T E C T S+A S S O C I A T E S2520 Durbin DriveCarmel , Indiana 46032317-733-8525hsark@sarkassociates.com1. THESE DRAWINGS INDICATE THE "GENERAL SCOPE" OF THE PROJECT IN TERMS OF THE ARCHITECTURAL ELEMENTS AND THE TYPE OF STRUCTURAL SYSTEM. AS SCOPE DOCUMENTS, THESE DRAWINGS DO NOT NECESSARILY INDICATE OR DESCRIBE ALL WORK REQUIRED FOR FULL PERFORMANCE AND COMPLETION OF THE REQUIREMENTS FOR CONSTRUCTION. AS SCOPE DOCUMENTS ALL STRUCTURAL ITEMS SHOWN ARE CONCEPTUAL AND HAVE NOT BEEN DESIGNED OR ENGINEERED BY SARK & ASSOCIATES. THE STRUCTURAL SYSTEM IN IT'S ENTIRETY ARE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. THE TRADE SUB-CONTRACTORS SHALL FURNISH ALL ITEMS REQUIRED FOR THE PROPER EXECUTION AND COMPLETION OF THE WORK. 2. ALL WORK ON THIS PROJECT MUST COMPLY WITH ALL CURRENT LOCAL, STATE, & NATIONAL CODES APPLICABLE. 3. VERIFY ALL EXISTING CONDITIONS PRIOR TO THE START OF CONSTRUCTION AND NOTIFY THE ARCHITECT IMMEDIATELY OF ANY CONFLICTS PRIOR TO PROCEEDING WITH THE WORK. 4. G.C. SHALL VERIFY ALL SOIL CONDITIONS AND ASSURE THAT THE SOIL BEARING CAPACITY IS ADEQUATE FOR ALL NEW FOOTING LOADING REQUIREMENTS. SPECIAL GENERAL CONDITIONS FIRST FLOOR - MASTER PLAN SCALE: 1/8" = 1'-0" FLOOR PLAN - MASTER PLAN A-4.0 166'-8"89'-0"54'-0" 14'-0"2'-4"18'-8"8'-0" 27'-0" 18'-8" 60'-4" 15'-4" 8'-8" 12'-8" 16'-0"89'-0"5'-8" 1'-4"2'-0" 17'-0" 16'-0" 9'-0" 16'-0"166'-8" 16'-0" 10'-0" 7'-0" 37'-8" 42'-4" 19'-0" 7'-0" 5'-8"9'-4"8'-0"23'-0"6'-0"14'-0"3'-0"9'-6"13'-0" 12'-6"14'-0"8'-0" U:\02-RESIDENTIAL L-Z\Nance, G\2020-0616_Fancher\01-CDs\2020-0710_Fancher_FF Plan.dwg, 10/20/2020 7:19:36 PM,_DWG To PDF.pc312/08/20