Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Truss stamp 11-24-20
16023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. RE: Design Code: IRC2018/TPI2014 Wind Code: N/A Wind Speed: 115 mph Roof Load: 50.0 psf Design Program: MiTek 20/20 8.2 1 of 1 This package includes 25 individual, dated Truss Design Drawings and 0 Additional Drawings. General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Floor Load: N/A psf November 23, 2020 Liu, Xuegang The truss drawing(s) referenced above have been prepared by MiTek USA, Inc under my direct supervision based on the parameters provided by ProBuild (CarterLee Bldg Components). Truss Design Engineer's Name: Liu, XuegangMy license renewal date for the state of Indiana is July 31, 2022. 11 Hamlet McKeznie 11 Hamlet IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek. Any project specific information included is for MiTek customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. Site Information: Lot/Block: Customer: Project Name: 11 Hamlet Subdivision: Address: State: City: Model: No. Seal# Truss Name Date 1 I41921418 CG01 11/23/2020 2 I41921419 GE01 11/23/2020 3 I41921420 GE02 11/23/2020 4 I41921421 GE03 11/23/2020 5 I41921422 GE04 11/23/2020 6 I41921423 GE05 11/23/2020 7 I41921424 GE06 11/23/2020 8 I41921425 J01 11/23/2020 9 I41921426 J02 11/23/2020 10 I41921427 J03 11/23/2020 11 I41921428 M01 11/23/2020 12 I41921429 M02 11/23/2020 13 I41921430 M03 11/23/2020 14 I41921431 M04 11/23/2020 15 I41921432 M05 11/23/2020 16 I41921433 M06 11/23/2020 17 I41921434 MG01 11/23/2020 18 I41921435 T01 11/23/2020 19 I41921436 T02 11/23/2020 20 I41921437 T03 11/23/2020 No. Seal# Truss Name Date 21 I41921438 T04 11/23/2020 22 I41921439 T05 11/23/2020 23 I41921440 T06 11/23/2020 24 I41921441 TG01 11/23/2020 25 I41921442 TG02 11/23/2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 11 Hamlet Truss CG01 Truss Type Diagonal Hip Girder Qty 2 Ply 1 McKeznie 11 Hamlet Job Reference (optional) I41921418 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:25:44 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:UJQXwL339PSw6nGLTOpm4?zHZxN-4OBCAnhsHa4ha2aFW8zm6hey8Fxz?SleLtTW5Ez_m?5 Scale = 1:21.2 1 2 6 5 7 3 8 42x4 4x6 2x4 1-6-01-6-0 5-7-24-1-2 -1-8-8 1-8-8 5-7-2 5-7-2 2-2-43-6-13-0-13-6-12.83 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.25 0.14 0.01 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.02 -0.03 0.02 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 240 n/a PLATES MT20 Weight: 27 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x6 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-7-2 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)6=0-4-9, 3=Mechanical, 4=Mechanical Max Horz 6=56(LC 5) Max Uplift 6=-88(LC 4), 3=-45(LC 8), 4=-17(LC 4) Max Grav 6=443(LC 1), 3=190(LC 1), 4=108(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-6=-389/50 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 3, 4. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 10 lb down and 14 lb up at 2-9-8, and 10 lb down and 14 lb up at 2-9-8 on top chord, and 1 lb down and 36 lb up at 2-9-8, and 1 lb down and 36 lb up at 2-9-8 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-80, 2-3=-80, 4-6=-20 July 6,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 11 Hamlet Truss GE01 Truss Type GABLE Qty 1 Ply 1 McKeznie 11 Hamlet Job Reference (optional) I41921419 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:25:45 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:UJQXwL339PSw6nGLTOpm4?zHZxN-YblaN7iU2uCYCB9S3rU?fuB83fJ9kuloaXC3dhz_m?4 Scale = 1:21.6 1 2 3 4 5 6 11 10 9 8 7 2x4 3x4 2x4 2x4 3x4 2x4 2x4 2x4 2x4 2x4 -1-2-8 1-2-8 4-7-8 4-7-8 2-2-43-8-124.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.17 0.01 0.09 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 -0.00 -0.00 (loc) 1 1 7 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 26 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-7-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 4-7-8. (lb) - Max Horz 11=104(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 11, 7, 9, 8 except 10=-101(LC 7) Max Grav All reactions 250 lb or less at joint(s) 11, 7, 10, 9, 8 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 7, 9, 8 except (jt=lb) 10=101. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. July 6,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 11 Hamlet Truss GE02 Truss Type GABLE Qty 2 Ply 1 McKeznie 11 Hamlet Job Reference (optional) I41921420 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:25:46 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:UJQXwL339PSw6nGLTOpm4?zHZxN-0nJzaSi7pCKPqLjedZ?EB6jL52fQTM4xpBycA7z_m?3 Scale = 1:27.6 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 28 27 26 25 24 23 22 21 20 19 18 17 16 3x8 2x4 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 5x6 2x4 2x4 2x4 2x4 2x4 2x4 16-7-416-7-4 16-7-4 16-7-4 1-3-11-7-30.25 12 Plate Offsets (X,Y)-- [25:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 1-4-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.03 0.01 0.02 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 16 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 49 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 16-7-4. (lb) - Max Horz 28=13(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 28, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27 Max Grav All reactions 250 lb or less at joint(s) 28, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Provide adequate drainage to prevent water ponding. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 28, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. July 6,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 11 Hamlet Truss GE03 Truss Type Monopitch Supported Gable Qty 2 Ply 1 McKeznie 11 Hamlet Job Reference (optional) I41921421 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:25:47 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:UJQXwL339PSw6nGLTOpm4?zHZxN-UztLoojlaVSGRVIqBGWTkJGW_S?hCpM41rhAiZz_m?2 Scale = 1:38.0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 2x4 3x6 5x6 2x4 2x4 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x6 2x4 22-9-1222-9-12 22-9-12 22-9-12 1-7-32-0-150.25 12 Plate Offsets (X,Y)-- [13:0-3-0,0-3-4] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 1-4-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.02 0.01 0.02 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 19 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 76 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 22-9-12. (lb) - Max Horz 37=9(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 31, 32, 33, 34, 35, 36 Max Grav All reactions 250 lb or less at joint(s) 37, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 31, 32, 33, 34, 35, 36 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Provide adequate drainage to prevent water ponding. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 31, 32, 33, 34, 35, 36. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. July 6,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 11 Hamlet Truss GE04 Truss Type GABLE Qty 1 Ply 1 McKeznie 11 Hamlet Job Reference (optional) I41921422 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:25:48 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:UJQXwL339PSw6nGLTOpm4?zHZxN-yARj?8kNLpa73ft1k_1iGXphisLyxGcEGVRjE0z_m?1 Scale = 1:28.7 1 2 3 4 5 6 7 8 9 10 11 12 13 14 28 27 26 25 24 23 22 21 20 19 18 17 16 15 2x4 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 5x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 5x6 2x4 2x4 2x4 2x4 2x4 3x6 2x4 17-3-017-3-0 17-3-0 17-3-0 1-3-12-0-150.57 12 Plate Offsets (X,Y)-- [10:0-3-0,0-3-0], [24:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 1-4-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.02 0.01 0.02 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 15 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 55 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 17-3-0. (lb) - Max Horz 28=32(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27 Max Grav All reactions 250 lb or less at joint(s) 28, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. July 6,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 11 Hamlet Truss GE05 Truss Type Monopitch Supported Gable Qty 1 Ply 1 McKeznie 11 Hamlet Job Reference (optional) I41921423 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:25:49 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:UJQXwL339PSw6nGLTOpm4?zHZxN-QM?5DUl?67i_hpSDIhZxpkLsQGh8gjrNV9AHmSz_m?0 Scale = 1:24.8 1 2 3 4 5 6 7 8 9 10 11 12 24 23 22 21 20 19 18 17 16 15 14 13 2x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x4 2x4 14-11-8 14-11-8 1-4-62-0-150.57 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 1-4-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.02 0.01 0.02 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 13 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 49 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 14-11-8. (lb) - Max Horz 24=32(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 24, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23 Max Grav All reactions 250 lb or less at joint(s) 24, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 24, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. July 6,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 11 Hamlet Truss GE06 Truss Type Monopitch Supported Gable Qty 1 Ply 1 McKeznie 11 Hamlet Job Reference (optional) I41921424 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:25:50 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:UJQXwL339PSw6nGLTOpm4?zHZxN-vYZTQqmdtQqrIz1PsP4AMyu06g0uPALXkpwqJuz_m?? Scale = 1:9.712 4 3 2x4 3x4 2x4 3x4 2-9-0 2-9-0 1-3-11-4-100.57 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 1-4-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.09 0.04 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 10 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-9-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)4=2-9-0, 3=2-9-0 Max Horz 4=20(LC 9) Max Uplift 4=-7(LC 6), 3=-1(LC 10) Max Grav 4=82(LC 1), 3=82(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 3. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. July 6,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 11 Hamlet Truss J01 Truss Type Jack-Open Qty 2 Ply 1 McKeznie 11 Hamlet Job Reference (optional) I41921425 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:25:51 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:UJQXwL339PSw6nGLTOpm4?zHZxN-Nl6seAmFekyiw6ccQ6bPu9RAo3My8cfgyTfNrKz_m?_ Scale = 1:17.5 1 2 6 5 3 4 2x4 3x4 2x4 1-6-01-6-0 2-0-70-6-7 -1-2-8 1-2-8 2-0-7 2-0-7 2-2-42-10-62-6-32-10-64.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.16 0.05 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.00 -0.00 -0.00 0.00 (loc) 6 5 3 5 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 10 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-0-7 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)6=0-3-8, 3=Mechanical, 4=Mechanical Max Horz 6=48(LC 7) Max Uplift 6=-27(LC 6), 3=-11(LC 10), 4=-25(LC 7) Max Grav 6=240(LC 1), 3=33(LC 1), 4=37(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 3, 4. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. July 6,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 11 Hamlet Truss J02 Truss Type Jack-Open Qty 2 Ply 1 McKeznie 11 Hamlet Job Reference (optional) I41921426 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:25:51 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:UJQXwL339PSw6nGLTOpm4?zHZxN-Nl6seAmFekyiw6ccQ6bPu9RAo3My8cfgyTfNrKz_m?_ Scale = 1:17.5 1 2 6 5 3 4 2x4 3x4 2x4 1-6-01-6-0 2-0-70-6-7 -1-2-8 1-2-8 2-0-7 2-0-7 2-2-42-10-62-6-32-10-64.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.16 0.05 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.00 -0.00 -0.00 0.00 (loc) 6 5 3 5 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 10 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-0-7 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)6=0-3-8, 3=Mechanical, 4=Mechanical Max Horz 6=48(LC 7) Max Uplift 6=-27(LC 6), 3=-11(LC 10), 4=-25(LC 7) Max Grav 6=240(LC 1), 3=33(LC 1), 4=37(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 3, 4. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. July 6,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 11 Hamlet Truss J03 Truss Type Jack-Open Qty 2 Ply 1 McKeznie 11 Hamlet Job Reference (optional) I41921427 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:25:52 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:UJQXwL339PSw6nGLTOpm4?zHZxN-rxgErWntP24YYGBozp6eRNzJuTfMt3TpB7PxMnz_m_z Scale = 1:20.6 1 2 6 5 3 4 2x4 3x4 2x4 1-6-01-6-0 4-0-02-6-0 -1-2-8 1-2-8 4-0-0 4-0-0 2-2-43-6-43-2-13-6-44.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.26 0.23 0.09 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.01 -0.02 -0.04 0.03 (loc) 5 4-5 3 4-5 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 15 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)6=0-3-8, 3=Mechanical, 4=Mechanical Max Horz 6=61(LC 7) Max Uplift 6=-24(LC 6), 3=-34(LC 10), 4=-1(LC 7) Max Grav 6=317(LC 1), 3=132(LC 1), 4=76(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-6=-279/13 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 3, 4. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. July 6,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 11 Hamlet Truss M01 Truss Type MONOPITCH Qty 8 Ply 1 McKeznie 11 Hamlet Job Reference (optional) I41921428 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:25:52 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:UJQXwL339PSw6nGLTOpm4?zHZxN-rxgErWntP24YYGBozp6eRNzIuTg0t4DpB7PxMnz_m_z Scale = 1:21.6 1 2 3 5 4 2x4 2x4 3x4 3x4 4-7-84-7-8 -1-2-8 1-2-8 4-7-8 4-7-8 2-2-43-8-123-5-40-3-83-8-124.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.33 0.19 0.04 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.02 -0.04 -0.00 0.00 (loc) 4-5 4-5 4 5 l/defl >999 >999 n/a **** L/d 360 240 n/a 240 PLATES MT20 Weight: 21 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-7-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-3-8, 4=0-1-8 Max Horz 5=104(LC 7) Max Uplift 5=-44(LC 6), 4=-32(LC 7) Max Grav 5=342(LC 1), 4=200(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-5=-299/162 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. July 6,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 11 Hamlet Truss M02 Truss Type MONOPITCH Qty 9 Ply 1 McKeznie 11 Hamlet Job Reference (optional) I41921429 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:25:53 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:UJQXwL339PSw6nGLTOpm4?zHZxN-J7Ec2soWALCP9Qm_XXdtzaWOctzpcW1zQn8UvDz_m_y Scale = 1:25.6 1 2 3 5 4 6 7 2x4 2x4 3x4 3x4 6-0-06-0-0 -1-2-8 1-2-8 6-0-0 6-0-0 2-2-44-2-43-10-120-3-84-2-44.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.65 0.35 0.07 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.06 -0.13 -0.00 0.00 (loc) 4-5 4-5 4 5 l/defl >999 >538 n/a **** L/d 360 240 n/a 240 PLATES MT20 Weight: 26 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-3-8, 4=0-1-8 Max Horz 5=74(LC 7) Max Uplift 5=-24(LC 6), 4=-39(LC 10) Max Grav 5=407(LC 1), 4=273(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-5=-350/147 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-2-8 to 1-9-8, Interior(1) 1-9-8 to 2-10-4, Exterior(2E) 2-10-4 to 5-10-4 zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. July 6,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 11 Hamlet Truss M03 Truss Type Monopitch Qty 16 Ply 1 McKeznie 11 Hamlet Job Reference (optional) I41921430 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:25:54 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:UJQXwL339PSw6nGLTOpm4?zHZxN-nKo_GBp8xfLGnaLA5E86Wo3YaHKULpt6fRu1Rfz_m_x Scale = 1:27.6 1 2 3 4 8 7 6 5 3x4 6x8 3x6 5x8 3x4 3x6 5x12 2x4 8-3-108-3-10 16-7-48-3-10 8-3-10 8-3-10 16-7-4 8-3-10 1-3-11-7-30.25 12 Plate Offsets (X,Y)-- [4:0-3-7,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 1-4-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.70 0.32 0.74 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.22 -0.36 0.01 0.14 (loc) 6 6 5 6 l/defl >909 >546 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 58 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 1-6,4-6: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-5-11 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)8=0-3-8, 5=0-2-12 Max Horz 8=13(LC 7) Max Uplift 8=-25(LC 6), 5=-26(LC 10) Max Grav 8=544(LC 1), 5=544(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-8=-480/185, 1-2=-2196/663, 2-4=-2197/669, 4-5=-481/188 BOT CHORD 6-8=-97/260 WEBS 1-6=-578/1945, 2-6=-461/253, 4-6=-626/2038 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 5. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. July 6,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 11 Hamlet Truss M04 Truss Type Monopitch Qty 16 Ply 1 McKeznie 11 Hamlet Job Reference (optional) I41921431 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:25:54 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:UJQXwL339PSw6nGLTOpm4?zHZxN-nKo_GBp8xfLGnaLA5E86Wo3YqHBiLq86fRu1Rfz_m_x Scale = 1:38.8 1 2 3 4 5 10 9 8 7 6 3x4 5x8 3x6 5x8 3x4 3x8 MT18HS5x8 4x6 6x10 2x4 7-10-47-10-4 15-5-07-6-12 23-3-47-10-4 7-10-4 7-10-4 15-5-0 7-6-12 23-3-4 7-10-4 1-7-32-1-00.25 12 Plate Offsets (X,Y)-- [5:0-3-7,0-2-8], [9:0-3-8,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 1-4-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.68 0.88 0.66 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.32 -0.55 0.04 0.18 (loc) 7-9 7-9 6 7-9 l/defl >854 >503 n/a >999 L/d 360 240 n/a 240 PLATES MT20 MT18HS Weight: 82 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 1-9,5-7: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-9-3 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 7-2-12 oc bracing. REACTIONS. (size)10=0-2-12, 6=0-5-8 Max Horz 10=9(LC 6) Max Uplift 10=-35(LC 6), 6=-37(LC 6) Max Grav 10=766(LC 1), 6=766(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-10=-707/200, 1-2=-2820/647, 2-4=-2587/593, 4-5=-2588/598, 5-6=-712/203 BOT CHORD 7-9=-659/2815 WEBS 1-9=-614/2681, 2-9=-360/171, 4-7=-428/189, 5-7=-592/2544 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 10. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 6. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. July 6,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 11 Hamlet Truss M05 Truss Type MONOPITCH Qty 11 Ply 1 McKeznie 11 Hamlet Job Reference (optional) I41921432 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:25:55 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:UJQXwL339PSw6nGLTOpm4?zHZxN-FWMMTXpmizT7PkvNfygL3?be6hfg4GvGt5dbz6z_m_w Scale = 1:28.7 1 2 3 4 8 7 6 5 3x4 6x8 3x6 5x8 3x4 3x6 5x12 2x4 8-7-88-7-8 17-3-08-7-8 8-7-8 8-7-8 17-3-0 8-7-8 1-3-12-0-150.57 12 Plate Offsets (X,Y)-- [4:0-3-6,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 1-4-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.97 0.32 0.75 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.20 -0.34 0.01 0.13 (loc) 7 5-7 5 7 l/defl >999 >602 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 61 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 1-7,4-7: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)8=0-5-8, 5=0-5-8 Max Horz 8=19(LC 7) Max Uplift 8=-26(LC 6), 5=-28(LC 10) Max Grav 8=565(LC 1), 5=565(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-8=-502/188, 1-3=-2019/585, 3-4=-2021/601, 4-5=-503/193 BOT CHORD 7-8=-111/257 WEBS 1-7=-497/1761, 3-7=-494/263, 4-7=-581/1924 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 5. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. July 6,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 11 Hamlet Truss M06 Truss Type MONOPITCH Qty 8 Ply 1 McKeznie 11 Hamlet Job Reference (optional) I41921433 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:25:56 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:UJQXwL339PSw6nGLTOpm4?zHZxN-jiwlhtqOSGb_0uUZCfBabD8x140Kpj7P6kN8VYz_m_v Scale = 1:24.8 1 2 3 6 5 4 3x4 5x8 6x6 3x4 6x8 2x4 7-5-127-5-12 14-11-87-5-12 7-5-12 7-5-12 14-11-8 7-5-12 1-4-62-0-150.57 12 LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 1-4-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.51 0.23 0.75 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.13 -0.21 0.00 0.08 (loc) 5 5 4 5 l/defl >999 >841 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 51 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-1 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)6=0-5-8, 4=0-5-8 Max Horz 6=18(LC 7) Max Uplift 6=-22(LC 6), 4=-24(LC 10) Max Grav 6=489(LC 1), 4=489(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-6=-433/175, 1-2=-1445/462, 2-3=-1447/476, 3-4=-434/182 WEBS 1-5=-392/1271, 2-5=-425/243, 3-5=-462/1379 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 4. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. July 6,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 11 Hamlet Truss MG01 Truss Type MONOPITCH GIRDER Qty 1 Ply 3 McKeznie 11 Hamlet Job Reference (optional) I41921434 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:25:56 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:UJQXwL339PSw6nGLTOpm4?zHZxN-jiwlhtqOSGb_0uUZCfBabD8sU4uMpkiP6kN8VYz_m_v Scale = 1:28.6 1 2 3 4 5 10 9 8 7 6 11 12 4x6 5x8 3x8 2x4 5x6 4x8 5x8 4x6 4x6 5x8 5-10-35-10-3 11-4-135-6-11 17-3-05-10-3 5-10-3 5-10-3 11-4-13 5-6-11 17-3-0 5-10-3 1-3-12-0-150.57 12 Plate Offsets (X,Y)-- [4:0-3-8,0-2-8], [9:0-3-8,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 1-4-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.80 0.74 0.65 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.19 -0.32 0.03 0.16 (loc) 7-9 7-9 6 7-9 l/defl >999 >636 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 213 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF 2100F 1.8E *Except* 1-3: 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 1-9: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)10=0-5-8, 6=0-5-8 Max Horz 10=31(LC 9) Max Uplift 10=-85(LC 6), 6=-84(LC 10) Max Grav 10=1808(LC 1), 6=1772(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-10=-1581/493, 1-2=-7655/2250, 2-4=-6555/1928 BOT CHORD 9-10=-168/524, 7-9=-2243/7641, 6-7=-1900/6496 WEBS 1-9=-2100/7203, 2-9=-1293/449, 2-7=-1170/350, 4-7=-17/301, 4-6=-6566/1932 NOTES- 1) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 6. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-11=-53, 11-12=-403, 5-12=-53, 6-10=-13 July 6,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 11 Hamlet Truss T01 Truss Type Hip Qty 1 Ply 1 McKeznie 11 Hamlet Job Reference (optional) I41921435 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:25:58 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:UJQXwL339PSw6nGLTOpm4?zHZxN-g52V6Zse_uriGBeyK4D2geDEnuepHemiZ2sFaQz_m_t Scale = 1:49.1 1 2 3 4 5 6 7 13 12 11 10 9 8 14 15 16 17 18 19 5x12 5x12 3x4 3x6 3x6 4x10 2x4 3x6 8x8 3x4 8x8 7-11-47-11-4 8-0-00-0-12 13-7-85-7-8 19-3-05-7-8 27-3-08-0-0 -1-2-8 1-2-8 8-0-0 8-0-0 13-7-8 5-7-8 19-3-0 5-7-8 27-3-0 8-0-0 28-5-8 1-2-8 2-2-44-8-114-10-42-2-44-8-114.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [3:0-6-0,0-1-11], [5:0-6-0,0-1-11], [6:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.69 0.49 0.68 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.09 -0.19 0.01 0.02 (loc) 8-9 8-9 8 9-10 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 111 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF 2100F 1.8E *Except* 3-5: 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 2-13,6-8: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 10-12. REACTIONS. (size)13=0-3-8, 12=0-3-8, 8=0-3-8 Max Horz 13=25(LC 9) Max Uplift 13=-63(LC 6), 12=-34(LC 6), 8=-81(LC 7) Max Grav 13=397(LC 23), 12=1516(LC 1), 8=1023(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=0/265, 3-4=-771/158, 4-5=-771/158, 5-6=-1106/139, 2-13=-327/141, 6-8=-948/185 BOT CHORD 9-10=-25/953 WEBS 3-12=-1273/178, 3-10=-91/1190, 4-10=-503/111, 2-12=-358/75, 6-9=-3/778 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-2-8 to 1-9-8, Interior(1) 1-9-8 to 3-9-1, Exterior(2R) 3-9-1 to 12-2-15, Interior(1) 12-2-15 to 15-0-1, Exterior(2R) 15-0-1 to 23-5-15, Interior(1) 23-5-15 to 25-5-8, Exterior(2E) 25-5-8 to 28-5-8 zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 13, 12, 8. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. July 6,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 11 Hamlet Truss T02 Truss Type Hip Qty 1 Ply 1 McKeznie 11 Hamlet Job Reference (optional) I41921436 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:25:58 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:UJQXwL339PSw6nGLTOpm4?zHZxN-g52V6Zse_uriGBeyK4D2geDEbuYUHaDiZ2sFaQz_m_t Scale = 1:49.1 1 2 3 4 5 6 7 8 13 12 11 10 9 14 15 16 17 18 19 5x12 4x8 3x6 3x6 3x6 3x12 3x6 3x4 3x6 4x8 3x4 7-11-47-11-4 17-3-09-3-12 27-3-010-0-0 -1-2-8 1-2-8 5-1-12 5-1-12 10-0-0 4-10-4 17-3-0 7-3-0 22-1-4 4-10-4 27-3-0 5-1-12 28-5-8 1-2-8 2-2-45-4-115-6-42-2-45-4-114.00 12 Plate Offsets (X,Y)-- [4:0-6-0,0-1-11] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.70 0.89 0.91 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.21 -0.42 0.02 0.02 (loc) 9-10 9-10 9 10 l/defl >999 >546 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 111 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 4-5: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 4-10: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-10-15 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-5. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (size)12=0-3-8, 13=0-3-8, 9=0-3-8 Max Horz 13=19(LC 9) Max Uplift 12=-32(LC 6), 13=-58(LC 6), 9=-77(LC 7) Max Grav 12=1603(LC 2), 13=393(LC 23), 9=1008(LC 24) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-4=0/340, 4-5=-865/157, 5-6=-953/142, 2-13=-309/127, 7-9=-324/124 BOT CHORD 9-10=-63/887 WEBS 3-12=-429/102, 4-12=-1129/144, 4-10=-28/873, 6-9=-1011/113 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-2-8 to 1-9-8, Interior(1) 1-9-8 to 5-9-1, Exterior(2R) 5-9-1 to 21-5-15, Interior(1) 21-5-15 to 25-5-8, Exterior(2E) 25-5-8 to 28-5-8 zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 13, 9. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. July 6,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 11 Hamlet Truss T03 Truss Type Hip Qty 1 Ply 1 McKeznie 11 Hamlet Job Reference (optional) I41921437 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:25:59 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:UJQXwL339PSw6nGLTOpm4?zHZxN-8HbtJvtHlBzZuLD8uokHDrmQvI?h05Hroibo6tz_m_s Scale = 1:49.1 1 2 3 4 5 6 7 8 15 14 13 12 11 10 9 16 17 18 19 4x6 5x12 3x6 2x4 5x8 4x10 3x6 3x6 3x8 3x6 3x8 2x4 8x8 7-11-47-11-4 12-0-04-0-12 15-3-03-3-0 21-1-45-10-4 27-3-06-1-12 -1-2-8 1-2-8 6-1-12 6-1-12 12-0-0 5-10-4 15-3-0 3-3-0 21-1-4 5-10-4 27-3-0 6-1-12 28-5-8 1-2-8 2-2-46-0-116-2-42-2-46-0-114.00 12 Plate Offsets (X,Y)-- [5:0-6-0,0-1-11], [7:0-2-8,Edge], [10:0-3-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.60 0.44 0.66 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.10 -0.19 0.02 0.02 (loc) 14-15 14-15 9 10-11 l/defl >960 >489 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 120 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-1-1 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 13-14. REACTIONS. (size)14=0-3-8, 15=0-3-8, 9=0-3-8 Max Horz 15=12(LC 9) Max Uplift 14=-15(LC 6), 15=-61(LC 6), 9=-76(LC 7) Max Grav 14=1339(LC 1), 15=529(LC 23), 9=1066(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-4=-617/147, 4-5=-512/161, 5-6=-879/157, 6-7=-1194/135, 2-15=-345/133, 7-9=-1007/166 BOT CHORD 13-14=-371/91, 11-13=0/750, 10-11=-33/1066 WEBS 3-14=-1312/178, 3-13=-72/1061, 5-13=-529/23, 5-11=0/329, 6-11=-391/65, 7-10=-44/1043 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-2-8 to 1-9-8, Interior(1) 1-9-8 to 7-9-1, Exterior(2R) 7-9-1 to 19-5-15, Interior(1) 19-5-15 to 25-5-8, Exterior(2E) 25-5-8 to 28-5-8 zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 14, 15, 9. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. July 6,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 11 Hamlet Truss T04 Truss Type COMMON Qty 6 Ply 1 McKeznie 11 Hamlet Job Reference (optional) I41921438 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:26:00 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:UJQXwL339PSw6nGLTOpm4?zHZxN-cT9FXFtvWV5QVVoKRVFWm3IaQiERlao?1MLMeJz_m_r Scale: 1/4"=1' 1 2 3 4 5 6 7 12 11 10 9 8 13 14 15 16 17 4x8 3x6 3x6 4x6 3x6 4x6 3x8 3x6 4x8 4x6 7-11-47-11-4 17-5-69-6-2 27-3-09-9-10 -1-2-8 1-2-8 6-11-8 6-11-8 13-7-8 6-8-0 20-3-8 6-8-0 27-3-0 6-11-8 28-5-8 1-2-8 2-2-46-8-122-2-44.00 12 Plate Offsets (X,Y)-- [6:0-3-0,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.68 0.86 0.45 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.24 -0.41 0.02 0.02 (loc) 9-11 8-9 8 9 l/defl >978 >560 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 110 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 4-11: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-2-9 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 4-11, 5-8 REACTIONS. (size)11=0-3-8, 12=0-3-8, 8=0-3-8 Max Horz 12=15(LC 10) Max Uplift 11=-12(LC 6), 12=-55(LC 6), 8=-69(LC 7) Max Grav 11=1625(LC 2), 12=411(LC 23), 8=1004(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-4=0/311, 4-5=-939/127, 2-12=-381/145, 6-8=-395/141 BOT CHORD 9-11=0/469, 8-9=-42/953 WEBS 3-11=-613/148, 4-11=-1046/44, 4-9=0/705, 5-9=-372/142, 5-8=-988/55 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-2-8 to 1-9-8, Interior(1) 1-9-8 to 10-7-8, Exterior(2R) 10-7-8 to 16-7-8, Interior(1) 16-7-8 to 25-5-8, Exterior(2E) 25-5-8 to 28-5-8 zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 12, 8. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. July 6,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 11 Hamlet Truss T05 Truss Type Common Qty 1 Ply 1 McKeznie 11 Hamlet Job Reference (optional) I41921439 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:26:01 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:UJQXwL339PSw6nGLTOpm4?zHZxN-4gjekbuXHpDH7fNX?CmlIGrkr5Z8Uyx8G04vBlz_m_q Scale: 1/4"=1' 1 2 3 4 5 6 7 13 12 11 9 8 14 15 16 17 18 10 19 4x8 3x6 3x6 4x10 3x6 4x10 4x6 4x8 4x8 4x6 9-2-39-2-3 14-0-04-9-13 18-0-134-0-13 27-3-09-2-3 -1-2-8 1-2-8 6-11-8 6-11-8 13-7-8 6-8-0 20-3-8 6-8-0 27-3-0 6-11-8 28-5-8 1-2-8 2-2-46-8-122-2-44.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-12], [6:0-3-0,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.76 0.96 0.78 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.21 -0.43 0.07 0.04 (loc) 8-9 8-9 8 8-9 l/defl >763 >370 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 109 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-5-15 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-13, 5-8 REACTIONS. (size)13=0-3-8, 8=0-3-8, 10=0-3-8 Max Horz 13=15(LC 14) Max Uplift 13=-69(LC 6), 8=-69(LC 7) Max Grav 13=1397(LC 1), 8=1395(LC 1), 10=181(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-4=-1677/177, 4-5=-1670/177, 2-13=-405/142, 6-8=-406/142 BOT CHORD 12-13=-40/1576, 10-12=0/1320, 9-10=0/1320, 8-9=-41/1572 WEBS 4-9=-22/458, 5-9=-255/142, 4-12=-21/469, 3-12=-254/142, 3-13=-1701/87, 5-8=-1695/88 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-2-8 to 1-9-8, Interior(1) 1-9-8 to 10-7-8, Exterior(2R) 10-7-8 to 16-7-8, Interior(1) 16-7-8 to 25-5-8, Exterior(2E) 25-5-8 to 28-5-8 zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 13, 8. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. July 6,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 11 Hamlet Truss T06 Truss Type Common Qty 4 Ply 1 McKeznie 11 Hamlet Job Reference (optional) I41921440 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:26:02 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:UJQXwL339PSw6nGLTOpm4?zHZxN-YsH0xxv926L8lpyjZwI_rUOvXVteDO2IUgqTjCz_m_p Scale: 1/4"=1' 1 2 3 4 5 6 7 12 11 10 9 8 13 14 15 16 17 18 4x8 3x6 3x6 5x8 3x6 5x8 4x6 4x8 4x8 4x6 9-2-39-2-3 18-0-138-10-11 27-3-09-2-3 -1-2-8 1-2-8 6-11-8 6-11-8 13-7-8 6-8-0 20-3-8 6-8-0 27-3-0 6-11-8 28-5-8 1-2-8 2-2-46-8-122-2-44.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-12], [6:0-3-0,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.76 1.00 0.85 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.23 -0.36 0.07 0.05 (loc) 9-11 8-9 8 9-11 l/defl >999 >900 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 109 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-3-3 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-12, 5-8 REACTIONS. (size)12=0-3-8, 8=0-3-8 Max Horz 12=15(LC 10) Max Uplift 12=-64(LC 6), 8=-64(LC 7) Max Grav 12=1462(LC 2), 8=1462(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-4=-1874/169, 4-5=-1874/169, 2-12=-403/142, 6-8=-403/142 BOT CHORD 11-12=-33/1712, 9-11=0/1451, 8-9=-33/1712 WEBS 4-9=-16/530, 4-11=-16/530, 3-12=-1861/79, 5-8=-1861/79 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-2-8 to 1-9-8, Interior(1) 1-9-8 to 10-7-8, Exterior(2R) 10-7-8 to 16-7-8, Interior(1) 16-7-8 to 25-5-8, Exterior(2E) 25-5-8 to 28-5-8 zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 8. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. July 6,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 11 Hamlet Truss TG01 Truss Type Hip Girder Qty 1 Ply 2 McKeznie 11 Hamlet Job Reference (optional) I41921441 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:26:04 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:UJQXwL339PSw6nGLTOpm4?zHZxN-UFPmMcwPakbr_655gLKSwvTHNJiwhIDby_JZn4z_m_n Scale = 1:49.1 1 2 3 4 5 6 7 14 13 12 11 10 9 81516171819202122 5x12 5x12 2x4 4x6 3x6 4x8 4x8 3x6 3x8 3x6 3x4 4x6 6-0-06-0-0 7-11-41-11-4 14-7-26-7-14 21-3-06-7-14 27-3-06-0-0 -1-2-8 1-2-8 6-0-0 6-0-0 13-7-8 7-7-8 21-3-0 7-7-8 27-3-0 6-0-0 28-5-8 1-2-8 2-2-44-0-114-2-42-2-44-0-114.00 12 Plate Offsets (X,Y)-- [3:0-6-0,0-1-11], [5:0-6-0,0-1-11], [9:0-3-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.61 0.44 0.87 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.07 -0.11 0.01 0.04 (loc) 9-10 9-10 8 9-10 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 250 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 12-13. REACTIONS. (size)14=0-3-8, 12=0-3-8, 8=0-3-8 Max Horz 14=-35(LC 19) Max Uplift 14=-52(LC 4), 12=-527(LC 4), 8=-265(LC 5) Max Grav 14=290(LC 21), 12=3822(LC 1), 8=1834(LC 22) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-39/389, 3-4=-108/953, 4-5=-2037/307, 5-6=-2351/341, 6-8=-1714/273 BOT CHORD 12-13=-373/67, 10-12=-230/1761, 9-10=-290/2155 WEBS 3-13=-97/648, 3-12=-1389/226, 4-12=-3221/461, 4-10=-122/1079, 5-9=-157/344, 2-13=-403/78, 6-9=-273/2145 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 14 except (jt=lb) 12=527, 8=265. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 370 lb down and 106 lb up at 4-0-12, 253 lb down and 59 lb up at 6-0-12, 253 lb down and 59 lb up at 7-2-4, 253 lb down and 59 lb up at 9-2-4, 253 lb down and 59 lb up at 11-2-4, 253 lb down and 59 lb up at 13-2-4, 253 lb down and 59 lb up at 15-2-4, 253 lb down and 59 lb up at 17-2-4, 253 lb down and 59 lb up at 19-2-4, and 253 lb down and 59 lb up at 21-2-4, and 370 lb down and 106 lb up at 23-2-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) StandardContinued on page 2 July 6,2020 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 11 Hamlet Truss TG01 Truss Type Hip Girder Qty 1 Ply 2 McKeznie 11 Hamlet Job Reference (optional) I41921441 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:26:04 2020 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:UJQXwL339PSw6nGLTOpm4?zHZxN-UFPmMcwPakbr_655gLKSwvTHNJiwhIDby_JZn4z_m_n LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-80, 2-3=-80, 3-5=-80, 5-6=-80, 6-7=-80, 8-14=-20 Concentrated Loads (lb) Vert: 11=-253 13=-253 9=-253 15=-370(B) 16=-253 17=-253 18=-253 19=-253 20=-253 21=-253 22=-370(B) 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 11 Hamlet Truss TG02 Truss Type Half Hip Girder Qty 2 Ply 1 McKeznie 11 Hamlet Job Reference (optional) I41921442 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Jul 6 14:26:05 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:UJQXwL339PSw6nGLTOpm4?zHZxN-zRz8ayx1L1jicGgIE2rhS60YUj86Qw5kAe27KXz_m_m Scale = 1:22.9 1 2 3 4 7 6 5 2x4 4x6 2x4 3x4 4x10 3x6 4-0-04-0-0 6-0-02-0-0 -1-2-8 1-2-8 4-0-0 4-0-0 6-0-0 2-0-0 2-2-43-6-44.00 12 Plate Offsets (X,Y)-- [3:0-5-0,0-1-13] LOADING (psf) TCLL TCDL BCLL BCDL 30.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.21 0.06 0.13 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.00 -0.01 0.00 0.00 (loc) 6-7 6-7 5 6 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 33 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=Mechanical, 7=0-3-8 Max Horz 7=60(LC 5) Max Uplift 5=-86(LC 4), 7=-62(LC 4) Max Grav 5=390(LC 1), 7=462(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-7=-415/80 WEBS 3-5=-359/86 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 7. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 129 lb down and 108 lb up at 4-0-0 on top chord, and 87 lb down and 66 lb up at 4-0-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-80, 2-3=-80, 3-4=-80, 5-7=-20 Concentrated Loads (lb) Vert: 6=-43(B) 3=-129(B) July 6,2020 PRODUCT CODE APPROVALSLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.21.The design does not take into account any dynamic or other loads other than those expressly stated.Failure to Follow Could Cause PropertyDamage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 5/19/2020edge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3- 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARING4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8WEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.dimensions shown in ft-in-sixteenths