Loading...
HomeMy WebLinkAboutTaylor Ortiz STR R1 5000 Gateway Dr. Ste 105 Medina, OH, 44256 330-419-2520 www.SynEngServices.com ajsniff@synengservices.com Client: YellowLite, 1925 St. Clair Ave NE, Cleveland, OH 44114 Subject: Structural Roof Evaluation To Whom It May Concern: We have reviewed the documents provided by Yellowlite relating to the installation of the solar array at the above- referenced site. Based upon our review, it is our conclusion that the installation of the solar array on this existing roof will not adversely affect this structure. It is our understanding that the structural components of the existing roof framing are in good condition and free of damage. The design of the solar panel racking (mounts, rails, etc.) and attachment is by the manufacturer or contractor. Please note a representative of Synergy Engineering has not physically observed the roof framing. Design Parameters Conclusions Code: Indiana Residential Building Code, Risk Category: II Design wind speed: 115 mph (3-sec gust) per ASCE 7-10 W ind exposure category: C Ground snow load: 20 psf Our conclusion regarding the adequacy of the existing roof is based on the fact that the additional weight of the solar array and attachment hardware is 4 psf or less. In the area of the solar array , other live loads will not be present or will be greatly reduced. Evaluation of expected loads and stress increase of the wood framing was made and shows sufficient reserve capacity in the roof framing members. Regarding snow loads, because the panels are slippery and unobstructed, effective snow loads will be reduced in the area of the solar array . The gravity loads in the area of the solar array are decreased; thus, the stresses of the structural elements are decreased. Based on these items, the proposed solar array is structurally acceptable to install per the areas shown in the Regarding lateral loads, the solar array will be flush-mounted (no more than 6" above the roof surface) and parallel to the roof surface. Thus, we conclude that any additional wind loading on the structure related to the addition of the proposed solar array is negligible. The connections to the existing roof shall be spaced at 48" maximum. Thus the existing structure is permitted to remain unaltered. Project Address: 3837 Penzance Place Carmel, IN 46032 following layout drawing. November 5 , 2020 12/17/20 5000 Gateway Dr. Ste 105 Medina, OH, 44256 330-419-2520 www.SynEngServices.com ajsniff@synengservices.com Limitations Installation of the solar panels must be performed in accordance with manufacturer recommendations. All work performed must be in accordance with accepted industry-wide methods and applicable safety standards. The contractor shall notify Synergy Engineering Services, LLC should any damage, deterioration or discrepancies between the as-built condition of the structure and the condition described in this letter be found. Particular attention must be paid to the maximum allowable spacing of connections and the location of solar panels relative to roof edges. Connections to existing roof framing must be staggered, except at array ends, so as not to overload any existing structural member. The use of solar panel support span tables provided by others is allowed only where the building type, site conditions, site-specific design parameters, and solar panel configuration match the description of the span tables. Electrical engineering is the responsibility of others. Waterproofing around the roof penetrations is the responsibility of others. Synergy Engineering Services, LLC assumes no responsibility for improper installation of the solar array. Synergy Engineering Services, LLC assumes no responsibility for the effects of snow falling from roofs onto other roofs, property or persons due to the installation of the solar array. Very truly yours, Synergy Engineering Services Adam J. Sniff, P.E. Consulting Engineer 12/17/20 5000 Gateway Dr. Ste 105 Medina, OH, 44256 330-419-2520 www.SynEngServices.com ajsniff@synengservices.com Figure 1. Layout of Array 1925 St. Clair Ave NE Cleveland, Ohio 44114 Phone: 216-333-1364 www.yellowlite.com Customer Signature PV Layout 11.2 kW Solar Photovoltaic Project: 1050 – AR Silfab SIL-320NL 66.9 x 39.3 x 1.5 in Anastasia Rowland-Seymour 15015 Onaway Rd Shaker Heights, OH 44120 PH: (315) 657-6162 System Details: · Residential 11.2kW grid tied (photovoltaic) system · This system has been designed in accordance with all current and applicable NEC, OBC, and RCO codes · Height of the Array: 3-4in above the roof, parallel to the roof · Weight of the Array: Less than 4lbs/ft^2 · Total Area of Array: 5.6ft x 3.3ft x 35 = 647 sq. ft. · Weight of the Array on Roof: 41.8lbs x 35 = 1463 lbs · Stress of Array on entire roof : 1463 lbs./647 sq.ft.= 2.26 lbs/sq. ft. · No fencing or trenching would be needed with this project SYSTEM: 35 x Silfab SIL-320 NL @ 320W – 11.2kW • AZIMUTH: R1: 286º, R2: 196º, R3: 106º • PITCH: R1,R2,R3: 37º Legend Utility Meter & AC Disconnect N S EW Inspection Notes for Crew 2 1 3 33' 2 3' 24' 14' 5" 24' 23 '29'2 3'29'23' Roof 1: West 06 x Modules Roof 3: East 06 x Modules Roof 2: South 23 x Modules 36" 36" 18" 18"36"18" 18" 18"18"12/17/20