Loading...
HomeMy WebLinkAboutTaylor Ortiz1925 St. Clair Ave NE Cleveland, Ohio 44114 Phone: 216-333-1364 www.yellowlite.com PV Layout 8.58 kW Solar Photovoltaic Project: 1306 – TO Silfab SIL-330 NL 66.9 x 39.4 x 1.5 in Taylor Ortiz 3837 Penzance Place Carmel, IN 46032 PH: (312) 523-9581 System Details: · Residential 8.58 kW grid tied (photovoltaic) system · This system has been designed in accordance with all current and applicable NEC, OBC, and RCO codes · Height of the Array: 3-4in above the roof, parallel to the roof · Weight of the Array: Less than 4lbs/ft^2 · Total Area of Array: 5.6ft x 3.3ft x 26= 481 sq. ft. · Weight of the Array on Roof: 41.4lbs x 26= 1076.4 lbs · Stress of Array on entire roof : 1076.4 lbs./481 sq.ft.= 2.24 lbs/sq. ft. · No fencing or trenching would be needed with this project SYSTEM: 26 x Silfab SIL-330 NL @ 330W – 8.58 kW • AZIMUTH: R1,R2: 191º • PITCH: R1,R2: 32º Legend Utility Meter & AC Disconnect N S EW Customer Signature Inspection Notes for Crew Project Manager: Jesse Varner PH: 440 935 5505 Email: jesse.varner@yellowlite.com Roof 1: South 24 x Modules 1 60'12'’24'12' 36"36'’1414'’12'’ Roof 2: South 02 x Modules 2 12/17/20 1925 St. Clair Ave NE Cleveland, Ohio 44114 Phone: 216-333-1364 www.yellowlite.com N S EW Property Details Total Land Area in Sq. ft.: 22,539.44 Total Area in Acreage: 0.52 Depth(ft.): 219 Frontage(ft.): 104 Right Setback(ft.): 09 Left Setback(ft.): 38 Front Setback(ft.): 34 Rear Setback(ft.): 109 Total Buildings in Property: 1 Building Height (Story): 2 Project Manager: Jesse Varner PH: 440 935 5505 Email: jesse.varner@yellowlite.com SITE PLAN 1306 – TO ADDRESS: 3837 Penzance Place Carmel, IN 46032 OWNER: Taylor Ortiz PH: (312) 523-9581 SYSTEM: 26 x Silfab SIL-330 NL @ 330W – 8.58 kW • AZIMUTH: R1,R2: 191º • PITCH: R1,R2: 32º 116'196'219'34'109'38' 9' Penzance P l Penzance P l Penzance P l 104' Legend Setbacks Inverter, Solar Meter, Utility Meter & AC Disconnect (Outside house) Main Service Panel (Inside Garage) AC Disco n n e c t Utility M e t e r Inverter & S o l a r M e t e r Main Ser v i c e P a n e l 12/17/20 Confidential Information: The contents of this document are subject to Non-Disclosure Agreement and shall not be disclosed. 1925 St Claire Ave NE Cleveland, Ohio 44114 Phone: 216-333-1364 www.yellowlite.com Module Specifications: Model: Silfab SIL-330 NL Mono Module Power (Pmax): 330W Maximum Power Voltage (Vpmax): 33.33V Maximum Power Current (Ipmax): 9.92A Open Circuit Voltage (Voc): 40.5V Short Circuit Current (Isc): 10.42A Module efficiency (%): 19.4 Max Series Fuse Rating: 20A Power Tolerance: 0 / +10W Cell Type: Mono-crystalline Number of cells: 60 Weight of Module: 19kg Dimensions (L x W x H mm): 1700 ˣ 1000 ˣ 38 Listing: ULC ORD C1703, UL1703, IEC 61215, IEC 61730-1 & IEC 61730-2 Certified, CEC Listed. UL Fire Rating: Type 2. Inverter Specifications: Model: SolarEdge SE7600H-US Rated AC Power Output : 7600VA Max. AC Output Power: 7600VA Nom. AC Frequency: 60Hz Nom. AC Voltage: 240Vac Max. Continuous Output Current: 32A Maximum DC Power (STC): 11800W Max. Input Voltage: 480V Nom. DC Input Voltage: 400 @ 240V Max. Input Current: 20A @ 240V Max. Input Short Circuit Current: 45A Maximum Inverter Efficiency: 99.2% Dimensions H / W / D: 17.7 / 14.6 / 6.8 inches Weight: 25.3lb / 11.5kg Listing: UL1741, UL1741 SA, UL1699B, CSA C22.2 Safety: NEMA3R / IP14, Grid Connection Standards: IEEE1547, Rule 21, Rule 14 (HI) Emissions: FCC Part 15 Class B System Specifications: System Type: Grid-Tied Mounting Method: Roof-Top Total DC rating of panels: 8.58 kW Total AC rating of inverter: 7.6 kVA Number of panels: 26 Number of inverters: 01 Online Monitoring: Cellular card AC Disconnect: Model: Eaton DG222NRB, 2-Pole, NEMA 3R Rating: 60A, 240 VAC Type: Fusible, Fuse Rating: 40A Dimensions: H: 14.38", W: 8.69", D: 4.21". Compliant with 690.13(B) & (C) and 690.15(A) & (B) The load center/disconnect will be visible, lockable, accessible to utility linesmen and will be properly labeled as per NEC requirements. It will be located on the exterior wall of the building, next to the utility meter. Optimizer Specifications: Model: SolarEdge Optimizer P340 Rated Input DC Power: 340W Absolute Maximum Input Voltage: 48V MPPT Operating Range: 8-48V Maximum Short Circuit Current: 11A Maximum efficiency (%): 99.5 Maximum Output Current: 15A Maximum Output Voltage 60V Safety Output Voltage per Optimizer: 1V Dimensions (W x L x H) in: 5.1 x 6 x 1.1 Weight: 1.4 lbs. Connector Type: MC4 Compatible Protection Rating: IP68 / NEMA6P Listing: FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3, IEC62109-1 (class II safety), UL1741 Rapid shut down is included in Inverter and Optimizers. See the attached files Grounding will be done via IronRidge Grounding Mid-clamps and WEEB Bonding Jumpers so the rail and panels will be continuously grounded. L1 L2 02 x Strings of 13 Modules AC Disconnect Fuse Rating: 40A Location: Next to Utility Meter Main Service Panel 240V/200A 1 ɸ service Location: Inside Garage AC ELECTRIC UTILITY GRID Utility Meter Location: Eastern wall of house N Inverter : SolarEdge SE7600H-US Location: Next to Utility Meter DC Disconnect M Solar Meter Location: Next to Utility Meter N G N L2 L1 AC Disconnect M Irreversible Splice to Existing EGC Voltage = 240 Vac Max AC Output Current = 32A x 1.25 = 40A Minimum Wire Size: #8 AWG THWN Cu NEC 2017 [Table 310.15 (B)(16)] EGC: #06 THHN AWG Copper [NEC 2017 690.45] [NEC 2017 Table 250.122] Line Side Connection in MSP EGC: #6 AWG Bare Cu [NEC 2017 690.45] [NEC 2017 Table 250.122] Project Manager: Jesse Varner PH: 440 935 5505 Email: jesse.varner@yellowlite.com SolarEdge Optimizer P340 Three Line Diagram 8.58 kW Solar Photovoltaic Project: 1306 – TO Taylor Ortiz 3837 Penzance Place Carmel, IN 46032 String Current = 10.72A String MPP Voltage = 30.77 Vdc x 13 = 400Vdc Voc = 1Vdc x 13 = 13Vdc Max. Current = 15A x 1.56 = 24A Max. Voltage = 480Vdc Wire Size: #10 AWG USE-2 Cu 1000V Black PV Wire (UL 4703 rated photovoltaic wire, single insulated) NEC 2017 [Table 310.15(B)(16)] EGC: #06 AWG THHN Cu [NEC 2017 690.45] [NEC 2017 Table 250.122] 12/17/20 PV Array Junction Box Inverter AC Disconnect Main Service PanelSolar MeterDC Disconnect Label #4, #11, #5, #10, #12 Label #6 Label #4, #9, #10 Label #1 Label #1 Label #1 Label #1 Label #1 Label #1 Label #2, #3 Label #4, #5, #6, #7, #8 DC JUNCTION BOX SOLAR CIRCUIT #2 #1 #3 #4 #5 #6 #7 #8 #9 #10 #11 #12 LABELS 1925 St Claire Ave NE Cleveland, Ohio 44114 Phone: 216-333-1364 www.yellowlite.comConfidential Information: The contents of this document are subject to Non-Disclosure Agreement and shall not be disclosed. Project Manager: Jesse Varner PH: 440 935 5505 Email: jesse.varner@yellowlite.com Three Line Diagram 8.58 kW Solar Photovoltaic Project: 1306 – TO Taylor Ortiz 3837 Penzance Place Carmel, IN 46032 12/17/20 Customer Signature N Page 1 of 2 Legend Utility meter & AC Disconnect Wiring Diagram 1306 – TO Project Manager: Jesse Varner PH: 440 935 5505 Email: jesse.varner@yellowlite.com String Configuration Inverter: SolarEdge SE7600H-US SYSTEM: 26 x Silfab SIL-330 NL @ 330W – 8.58 kW • AZIMUTH: R1,R2: 191º • PITCH: R1,R2: 32º ADDRESS: 3837 Penzance Place Carmel, IN 46032 OWNER: Taylor Ortiz PH: (312) 523-9581 1 x String of 13Modules Use two Soladecks to run DC conduit internally via attic 1 x String of 13 Modules Soladeck 1 Soladeck 2 12/17/20 Customer Signature Page 2 of 2 Wiring Diagram 1306 – TO Project Manager: Jesse Varner PH: 440 935 5505 Email: jesse.varner@yellowlite.com SYSTEM: 26 x Silfab SIL-330 NL @ 330W – 8.58 kW • AZIMUTH: R1,R2: 191º • PITCH: R1,R2: 32º ADDRESS: 3837 Penzance Place Carmel, IN 46032 OWNER: Taylor Ortiz PH: (312) 523-9581 DC conduit run AC conduit run Legend AC Disconnect Utility Meter Inverter Solar Meter Lineside tap connection to be done in 200A Main Service Panel Use cellular card for the online monitoring Eastern wall Garage 200A Main Service Panel Penetrate into the Main Service Panel rear 12/17/20