Loading...
HomeMy WebLinkAbout20139 - MureMSP 171'-11"108'-9"150'-4"16'-6"46'-9"31'-0"61'-2"30'-5"4'-1"45'-8"MSPREV SHEET NAME SHEET SIZE SHEET NUMBERJOSHUA MURER11978 WINNERS CIRCARMEL, IN 46032USAANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-1 SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 20139 1 2 3 PROJECT DESCRIPTION: PLOT PLAN & VICINITY MAP HOUSE PHOTO VICINITY MAP SCALE: 1/32" = 1' PV-1 SCALE: NTS PV-1 PV-1 SCALE: NTS PROJECT SITE PLOT PLAN & VICINITY MAP 55 X SUNPOWER SPR X22-370 (370W) MODULES ROOF MOUNTED SOLAR PHOTOVOLTAIC SYSTEM SYSTEM SIZE: 20.350 KW DC STC EQUIPMENT SUMMARY 55 SUNPOWER SPR X22-370 (370W) MODULES 04 SMA SUNNY BOY 5.0-1SP-US-40 (240) INVERTERS PROJECT SITES GOVERNING CODES ALL WORK SHALL CONFORM TO THE FOLLOWING CODES 2012 INDIANA BUILDING CODE 2012 INDIANA FIRE CODE 2012 INDIANA FUEL GAS CODE 2012 INDIANA MECHANICAL CODE 2012 INDIANA PLUMBING CODE 2012 INDIANA RESIDENTIAL CODE 2008 NFPA 70-NATIONAL ELECTRICAL CODE DESIGN SPECIFICATIONS EXPOSURE CATEGORY = B WIND SPEED = 115MPH GROUND SNOW LOAD = 20 PSF ZONING = RESIDENTIAL CONSTRUCTION = SINGLE FAMILY EXISTING NEW (E) (N) DESCRIPTION SHEET INDEX PV-1 PLOT PLAN & VICINITY MAP PV-2 ROOF PLAN & MODULES PV-2A STRING LAYOUT PV-3 ENGINEERING REPORT PV-4 ATTACHMENT DETAIL PV-5 ELECTRICAL LINE DIAGRAM PV-6 WIRING CALCULATIONS PV-7 PLACARDS PV-8+ EQUIPMENT SPECIFICATIONSWINNERS CIRROOF #1 (40) SUNPOWER SPR X22-370 (370W) MODULES (E) MAIN HOUSE ROOF #2 (15) SUNPOWER SPR X22-370 (370W) MODULES (E) MAIN SERVICE PANEL(INSIDE) PROPERTY LINE EXISTING DRIVEWAY 2-STORYHOUSEGARAGE 12/17/20 UM MSP INV ACD INV SLCINVINV PVCMSPGW PW PW REV SHEET NAME SHEET SIZE SHEET NUMBERJOSHUA MURER11978 WINNERS CIRCARMEL, IN 46032USAANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-2 SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 20139 GROUND PLAN & MODULES LEGEND - INVERTERINV MSP - MAIN SERVICE PANEL - VENTS, (ROOF OBSTRUCTION) - CONDUIT - UTILITY METERUM 1 PV-2 GROUND PLAN & MODULES SCALE: 3/32" = 1'-0" - CHIMNEY MODULE TYPE, DIMENSIONS & WEIGHT - PVC JUNCTION BOXPVC ACD - AC DISCONNECT SLC - SOLAR LOAD CENTER DCD - DC DISCONNECT NUMBER OF MODULES =55 MODULES MODULE TYPE = SUNPOWER SPR X22-370 (370W) MODULES MODULE WEIGHT = 41.0 LBS / 18.6 KG. MODULE DIMENSIONS = 61.3"x 41.2" = 17.54 SF UNIT WEIGHT OF ARRAY = 2.34 PSF SUNPOWER SPR X22-370 (370W) MODULES 41.2"61.3"ROOF DESCRIPTION ROOF TYPE COMP SHINGLE ROOF ROOF ROOF TILT AZIMUTH RAFTER SIZE RAFTER SPACING #1 35° 270° 2"x4" 24" O.C. #2 35° 270° 2"x4" 24" O.C. ARRAY AREA WITH ROOF AREA ROOF # OF MODULES ARRAY AREA (Sq. Ft.) ROOF AREA (Sq. Ft.) ROOF AREA COVERED BY ARRAY (%) #1 40 701.60 874.00 80.27 #2 15 263.10 489.25 53.78 (E) FRONT OF RESIDENCEWINNERS CIR,(E) BACK OF RESIDENCEROOF #1 (40) SUNPOWER SPR X22-370 (370W) MODULES ROOF #1 (15) SUNPOWER SPR X22-370 (370W) MODULES (80) PV ATTACHMENTS @ 72" O.C. (N) EVEREST CR-48 RACKING SYSTEM ROOF #1 TILT - 35° AZIM. - 270° ROOF #2 TILT - 35° AZIM. - 270° (N) 3/4" EMT CONDUIT (N) PVC JUNCTION BOX (E) MAIN SERVICE PANEL (INSIDE) (E) UTILITY METER (N) AC DISCONNECT (N) SOLAR LOAD CENTER (N) 4-SMA SUNNY BOY 5.0-1SP-US-40 (240) INVERTERS (E) MAIN SERVICE PANEL (INSIDE) (N) ENERGY GATEWAY (N) 2X POWER WALL (N) EVEREST CR-48 RACKING SYSTEM (80) PV ATTACHMENTS @ 72" O.C. 12/17/20 UM MSP INV ACD INV SLCINVINV PVCMSPGW PW PW REV SHEET NAME SHEET SIZE SHEET NUMBERJOSHUA MURER11978 WINNERS CIRCARMEL, IN 46032USAANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-2A SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 20139 STRING LAYOUT 1 STRING LAYOUT PV-2A SCALE: 1/8" = 1'-0" BILL OF MATERIALS EQUIPMENT QTY DESCRIPTION SOLAR PV MODULE 55 SUNPOWER SPR X22-370 (370W) MODULES INVERTER 4 SMA SB5.0-US (240V) INVERTER AC DISCONNECT 1 200A FUSED,(2) 120A FUSES,240 NEMA 3R, UL LISTED ATTACHMENT 80 ECO FASTEN FLASHING L-FEET ATTACHMENT RAILS 30 EVEREST CR-48 RAIL RACKING SYSTEM(166") RAIL SPLICE 22 SPLICE KIT MID CLAMPS 92 MID CLAMPS END CLAMPS 36 END CLAMPS / STOPPER SLEEVE GROUNDING LUG 9 GROUNDING LUG (E) FRONT OF RESIDENCEBRYAN STATION ROAD(E) BACK OF RESIDENCESTRING #1(07) STRING #2(07) STRING #3(07) STRING #5(07) STRING #4(07) STRING #6(07) STRING #7(07) STRING #8(06) 12/17/20 5'-8" 13'-10" 6'-3" 11" 13'-10" 13'-10" 8'-1" 1'-4" 1'-7" 20'-8"8"8"15'-6" 2'-10" REV SHEET NAME SHEET SIZE SHEET NUMBERJOSHUA MURER11978 WINNERS CIRCARMEL, IN 46032USAANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-3 SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 20139 ATTACHMENT 1 RACKING DIAGRAM PV-3 SCALE: 3/32"=1'-0" 12/17/20 REV SHEET NAME SHEET SIZE SHEET NUMBERJOSHUA MURER11978 WINNERS CIRCARMEL, IN 46032USAANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-4 SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 20139 RACKING PLAN ATTACHMENT DETAILS SCALE: NTS 1 PV-4 2"X4" RA F T E R S @ 24" O.C 2 ATTACHMENT DETAIL (FRONT VIEW) PV-4 SCALE: NTS SEE (2/PV-4) FOR ENLARGED VIEW PV MODULES EVEREST CR-48 RAIL 2"X4" RAFTERS @ 24" O.C. (1) 5/16"Ø X 6", 18-8 SS HANGER BOLT,PLAIN CENTER. 2 1/2" MIN. EMBEDMENT PV MODULE ECOFASTEN FLASHING ECOFASTEN L-FOOT MID CLAMP (E) COMPOSITION SHINGLE ROOF 12/17/20 REV SHEET NAME SHEET SIZE SHEET NUMBERJOSHUA MURER11978 WINNERS CIRCARMEL, IN 46032USAANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-5 SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 20139 ELECTRICAL LINE DIAGRAM CONDUIT CONDUCTOR SCHEDULE (ALL CONDUCTORS MUST BE COPPER/ALUMINIUM) Tag # 1 1 3 3 4 4 Bare Copper Ground (EGC/GEC) THWN-2 (CU) PV WIRE THWN-2 - Ground THWN-2 - Ground Description Wire Gauge # of Conductors/Color Conduit Type Conduit Size 10 AWG 6 AWG 8 AWG 10 AWG 6 AWG 3 (1V+, 1V-) 1 BARE 1 (GRN) 1 (GRN) N/A-Free Air N/A-Free Air EMT N/A-Free Air N/A-Free Air 3/4" 3/4"EMT 1 AWG 3 (L1,L2,N) B/R/W THWN-2 (CU) EMT EMT 2 2 THWN-2 (CU) THWN-2 - Ground 10 AWG 10 AWG 6 (3V+, 3V-) B/R 1 (GRN) 1-1/4" 1-1/4" EMT 3/4" EMT 3/4" 3 (L1,L2,N) B/R/W - + - + 2 - + 1 3 - + - + 2 - + 1 3 1 DC ACDC DC (N) SOLAR LOAD CENTER 240V, 100AMP, NEMA 3R, UL LISTED G N L1 L2 N 3 3 4 PVC JUNCTION BOX - + - + - + - + (E) MAIN SERVICE PANEL, 200A RATED, 240V EXISTING GROUNDING ELECTRODE SYSTEM GEC G N EXISTING GROUNDING ELECTRODE SYSTEM GEC G N 200A 125A 2 L2 L1 30A/2P L2 L1 30A/2P 4 L1 L2 N G L1 L2 N G AC DISCONNECT: 150A FUSED, (2) 120A FUSES, 240V NEMA 3R, UL LISTED - + - + 2 - + 1 3 - + - + 2 - + 1 3 1 = DC ACDC DC PVC JUNCTION BOX - + - + - + - + 2 LINE SIDE TAP - + - + 2 - + 1 3 - + - + 2 - + 1 3 1 = DC ACDC DC 3 PVC JUNCTION BOX - + - + - + - + 2 L2 L1 30A/2P - + - + 2 - + 1 3 6 7 - + - + 2 - + 1 3 1 = DC ACDC (N) INVERTER: #1 SMA SB-5.0-US-40 (240) OUTPUT: 240 VAC, 24A 97% CEC WEIGHTED EFFICIENCY NEMA 3R, UL LISTED, INTERNAL GFDI WITH INTEGRATED DC DISCONNECT DC 3 PVC JUNCTION BOX - + - + - + - + 2 (N) SUNPOWER SPR X22-370 (370W) MODULES L2 L1 30A/2P (N) INVERTER: #2 SMA SB-5.0-US-40 (240) OUTPUT: 240 VAC, 24A 97% CEC WEIGHTED EFFICIENCY NEMA 3R, UL LISTED, INTERNAL GFDI WITH INTEGRATED DC DISCONNECT (N) INVERTER: #3 SMA SB-5.0-US-40 (240) OUTPUT: 240 VAC, 24A 97% CEC WEIGHTED EFFICIENCY NEMA 3R, UL LISTED, INTERNAL GFDI WITH INTEGRATED DC DISCONNECT = (N) INVERTER: #4 SMA SB-5.0-US-40 (240) OUTPUT: 240 VAC, 24A 97% CEC WEIGHTED EFFICIENCY NEMA 3R, UL LISTED, INTERNAL GFDI WITH INTEGRATED DC DISCONNECT 6 7 6 7 6 7 6 7 6 7 6 7 5 6 SYSTEM SIZE: TOTAL DC SYSTEM SIZE: 20.35 kW DC TOTAL AC SYSTEM SIZE: 20.00 kW AC (55) SUNPOWER SPR X22-370 (370W) MODULES (04) SMA SUNNY BOY 5.0-1SP-US-40 (240) INVERTERS (07) STRINGS OF 7 MODULES (01) STRING OF 6 MODULES (CONNECTED IN SERIES PER STRING) L2 L1 30A/2P L2 L1 30A/2P EXISTING GROUNDING ELECTRODE SYSTEMTO 2 (N) POWERWALL TESLA P/N 1092170-XX-X 5KW, 13.5KWH NEMA 3R (4) [24-16] AWG THWN-2 (3) [10-8] AWG THWN-2 (1) [10-8] AWG GND EXISTING GROUNDING ELECTRODE SYSTEM TO 2 (N) POWERWALL TESLA P/N 1092170-XX-X 5KW, 13.5KWH NEMA 3R (4) [24-16] AWG THWN-2 (3) [10-8] AWG THWN-2 (1) [10-8] AWG GND G N GEC (N) BACKUP GATEWAY TESLA P/N 1118431-XX-X 200A MAX, NEMA 3R TO 6 TO 200A NL2 L1 M BI-DIRECTIONAL UTILITY METER 1-PHASE, 3-W, 120V/240V TO UTILITY GRID 4 CT LEADS BY TESLA 12/17/20 REV SHEET NAME SHEET SIZE SHEET NUMBERJOSHUA MURER11978 WINNERS CIRCARMEL, IN 46032USAANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-6 SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 20139 WIRING CALCULATIONS ELECTRICAL NOTES 1.) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. 2.) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. 3.) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 4.) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. 5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 6.) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 7.) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8.) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. 9.) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. 10.) THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE NUMBER OF CURRENT CARRYING CONDUCTORS IN EMT 4-6 7-9 10-20 PERCENT OF VALUES .80 .70 .50 EXPECTED WIRE TEMP (In Celsius) NO. OF CURRENT CARRYING CONDUCTORS CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) CIRCUIT CONDUCTOR SIZE 1 10 AWG 2 32 TEMP. CORRECTION PER TABLE (310.16) 0.96 CIRCUIT CONDUCTOR AMPACITY 40A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B) 1.25 X 1.25 X Isc 10.41A DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 TEMP. CORRECTION PER TABLE (310.16) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY 38.4A Result should be greater than (10.41A) otherwise less the entry for circuit conductor size and ampacity REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B) 1.25 X 1.25 X Isc 10.41A DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 TEMP. CORRECTION PER TABLE (310.16) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY 24.32A Result should be greater than (10.41A) otherwise less the entry for circuit conductor size and ampacity AC CONDUCTOR AMPACITY CALCULATIONS: FROM INVERTER TO SOLAR LOAD CENTER No. OF INVERTER NO. OF CURRENT CARRYING CONDUCTORS CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) CIRCUIT CONDUCTOR SIZE 1 8AWG 3 4 TEMP. CORRECTION PER TABLE (310.16) 0.94 CIRCUIT CONDUCTOR AMPACITY 50A EXPECTED WIRE TEMP (In Celsius) 32 REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B) 1.25 X MAX INVERTER OUTPUT CURRENT 30A DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 TEMP. CORRECTION PER TABLE (310.16) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY 47.0A Result should be greater than (30A) otherwise less the entry for circuit conductor size and ampacity AMBIENT TEMPERATURE SPECS AMBIENT TEMP (HIGH TEMP 2%) RECORD LOW TEMP -22° 32° CONDUIT HEIGHT 0.5" ROOF TOP TEMP 54° CONDUCTOR TEMPERATURE RATE 90° MODULE TEMPERATURE COEFFICIENT OF Voc -0.29%/°C DC CONDUCTOR AMPACITY CALCULATIONS: FROM PVC JUCTION BOX TO INVERTER : AMBIENT TEMPERATURE ADJUSTMENT FOR EXPOSED CONDUIT PER NEC 310.15(B)(2)(c) NO. OF CURRENT CARRYING CONDUCTORS CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) CIRCUIT CONDUCTOR SIZE 0.80 10 AWG 4 +22 TEMP. CORRECTION PER TABLE (310.16) 0.76 CIRCUIT CONDUCTOR AMPACITY 40A EXPECTED WIRE TEMP (In Celsius) 32 +22 = 54 DC CONDUCTOR AMPACITY CALCULATIONS: ARRAY TO PVC JUCTION BOX : INVERTER #1,2,3 & 4 SPECIFICATIONS MANUFACTURER MODEL # 5.0-1SP-US-40 SMA SUNNY BOY NOMINAL AC POWER 5.0 KW NOMINAL OUTPUT VOLTAGE 240V NOMINAL OUTPUT CURRENT 24.0A SOLAR MODULE SPECIFICATIONS MANUFACTURER MODEL # PMAX VMP IMP VOC ISC 370W SPR X22-370 SUNPOWER MODULE DIMENSION 59.10A 6.26A 69.5V 6.66A 61.3"x 41.2" x 1.8"D (In Inch) AC CONDUCTOR AMPACITY CALCULATIONS: FROM SOLAR LOAD CENTER TO MSP No. OF LOAD CENTER NO. OF CURRENT CARRYING CONDUCTORS CONDUIT FILL CORRECTION PER NEC 310.15(B)(3)(a) #1 CIRCUIT CONDUCTOR SIZE 1 1 AWG 3 1 TEMP. CORRECTION PER TABLE 310.15(B)(2)(a) 0.94 CIRCUIT CONDUCTOR AMPACITY 130A EXPECTED WIRE TEMP (In Celsius) 32° REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B) 1.25 X MAX SOLAR LOAD CENTER CURRENT 120.0A DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.15(B)(2)(a) TEMP. CORRECTION PER TABLE 310.15(B)(2)(a) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(3)(a) X CIRCUIT CONDUCTOR AMPACITY 122.2A Result should be greater than (120.0A) otherwise less the entry for circuit conductor size and ampacity 12/17/20 REV SHEET NAME SHEET SIZE SHEET NUMBERJOSHUA MURER11978 WINNERS CIRCARMEL, IN 46032USAANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-7 SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 20139 PLACARDS CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN AT: MAIN SERVICE/UTILITY METER AC DISCONNECT SOLAR LOAD CENTER INVERTER LABEL LOCATION: AT MSP : NEC 705.10 & 690.56 (B) SOLAR DISCONNECT LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: CEC690.13(B)) PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OPERATING CURRENT 64.0 AMPS AC NOMINAL OPERATING VOLTAGE 240 VOLTS LABEL LOCATION: DISCONNECT, POINT OF INTERCONNECTION (PER CODE: CEC690.13(B)) PER NEC 705.12(B)(2)(3)(c) THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR WARNING WARNING: PHOTOVOLTIC POWER SOURCE Per NEC 690.31(G) (3)(4) Place on all source markings. Place on Conduit every 10 ft. (IFC 605.11.1.1 and IFC 605.11.1.2) WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE. PER NEC 705.12(B)(2)(3)(b) WARNING DUAL POWER SOURCE SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM 4" x 2", RED AND WHITE LETTERS PER NEC 705.12(D)(3) & NEC 690.64 ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING PER NEC 690.13 (B) THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR WARNING PER NEC 705.12(B)(2)(3)(c) Per NEC NEC 690.13(B) PHOTOVOLTIC AC DISCONNECT WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE. PER NEC 705.12(B)(2)(3)(b) PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN PER NEC 690.56(C) RATED MAXIMUM POWER- . POINT CURRENT (Imp) . RATED MAXIMUM POWER- . POINT VOLTAGE (Vmp) . MAXIMUM SYSTEM . VOLTAGE (VOC) . MAXIMUM CIRCUIT . CURRENT (Isc) . 413.7 540.02 16.65 12.52 A V LABEL LOCATION: DC DISCONNECT, INVERTER (PER CODE: CEC690.53) V A INVERTER #1, #2 #3 & #4 WINNERS CIR PV SOLAR (E) MAIN SERVICE PANEL (INSIDE) (E) UTILITY METER (N) AC DISCONNECT (N) SOLAR LOAD CENTER (N) INVERTERS (E) MAIN SERVICE PANEL (INSIDE) 12/17/20 REV SHEET NAME SHEET SIZE SHEET NUMBERJOSHUA MURER11978 WINNERS CIRCARMEL, IN 46032USAANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-8 SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 20139 EQUIPMENT SPECIFICATION 12/17/20 REV SHEET NAME SHEET SIZE SHEET NUMBERJOSHUA MURER11978 WINNERS CIRCARMEL, IN 46032USAANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-9 SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 20139 EQUIPMENT SPECIFICATION 12/17/20 REV SHEET NAME SHEET SIZE SHEET NUMBERJOSHUA MURER11978 WINNERS CIRCARMEL, IN 46032USAANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-10 SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 20139 EQUIPMENT SPECIFICATION 12/17/20 REV SHEET NAME SHEET SIZE SHEET NUMBERJOSHUA MURER11978 WINNERS CIRCARMEL, IN 46032USAANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-11 SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 20139 EQUIPMENT SPECIFICATION 12/17/20