HomeMy WebLinkAboutLS1-102-SECOND-AND-THIRD-FLOOR-LIFE-SAFETY-PLANS-Rev.0m � _ V � Q m � _ m a 0 m v � w � E _ v � � a . z 3 � BUILOING CODES REFERENCED 2014 INDIANA BUILDING CODE (2012 IBQ 15T PRINTMG) 2012 INDIANA PLUMBING CODE 20141NDIANA MECHANICAL CODE (20121MC, iST PRWTING) 20141NDIANA FIRE CODE (20121FC, 1ST PRINTING) 20091NDIANA ELECTRICAL CODE (NFPA 10-20�8) ASHRAE 90.1-200] EOITION ANSIAII].L2009 DESCRIPTION W 000 FRAMED CONSTRUCTION W ITH A COMBINATION OF MASONRV, CEMENT FIBER BOARD AND EXTERIOR INSULATED FINISH SYSTEM. TVPE R-2 PRIMARV OCWPANCV TVPE V-A CONSTRUCTION FOl1R STORY APARTMENT BUILDING BUILDING AREA BUILDING 1 NORTH GROUND FLOOR- 20,982 GSF FIRST FLOOR- 20,936 GSF SECOND FLOOR- 20,936 GSF THIRD FLOOR- 20,936 GSF TOTAL- 83,790 GSF BUILDING 1 SOUTH GROUND FLOOR- FIRST FLOOR- SECOND FLOOR- THIRD FLOOR- TOTAL- AUTOMATIC FIRE SUPPRESSION SYSTEM BUILDING IS RE�UIRED TO HAVE AND IS PROVIDED THROUGHOUT W ITH AUTOMATIC SPRMKLER SVSTEM IN ACCORDANCE W ITH NFPA 13R AND IBC 903.3.1 2. FIRE EXTINGUISHERS FlRE EXTWGUISHER CABMETS AT �5' MAX TRAVEL. FIRE ALARM SVSTEM COMPLETE FIRE ALARM SVSTEM REQUIRED AND PROVIDED IN ACCORDANCE WITH NFPA72AND IBC. PROVIDE VISUAL NOTIFICATION (STROBES) IN ACCESSBLE UNITS IN ACCORDANCE WITH NFPA]2. OCCUPANCVGROUP SECTION 310 3 OCCl1PANCV R2 OCCUPANCY; (RESIDENTIAL, APARTMENT) M MERCANTILE (RETAIL) B BUSINESS (OFFICES) SEPARATED MIXED USE PER IBC 508; OCCUPANCV SEPARATIONS INDICATED ON FLOOR PLAN SECTION 510.9 MULTIPLE BUIL�INGS ABOVE A HORIZONTAL ASSEMBLV SHALL BE REGARDED AS SEPARATE BUILDINGS . MEANS OF EGRE55 BUILDING 1� NORTH AND SOUTH 3,71JGSF REpUIREMENT REQUIRED PROVIDEO 2,829GSF NUMBEROFEXITS 2PERFLOOR 2PERFLOOR 3,719 GSF $ 719 GSF STAIR WIDTH 44" MIN 48" WI�TH PROVIDED 13,986GSF CORRIDORWIDTH 44"MIN 60"MIN EGRESS DOOR SIZE 32" MIN 32" MIN PROVIDED BUILDING 1 E�UIPPED WRH NFPA 73 SPRINKLER SVSTEM IN ACCORDANCE WITH SECTION 903.3.1.1 TABLE 601 CONSTRUCTION TVPE: V-A SECTION 708 FIRE BLOCKING REQUIRED SECTION 718.31 DRAFTSTOPPING REQUIRED IN FLOORS, AT EVERY SLEEPING UNIT SECTION 718.4.2 DRAFTSTOPPING IN ATTICS: REpUIRED, EVERV 3,000 SF SECTION 9032.8 GROUP R- AUTOMATIC SPRMKLER SYSTEM NFPA 13R REQUIRED. SECTION7023 STAIRWAYS-ENCLOSUREMINIMUMOF2HRRATING SECTION SMOKEPROOFENCLOSURES-NOTREp.WHERETOPFLOORIS 7023.77 LESS THAN 75 FT ABOVE FIRE DEPARTMENT ACCESS. (FLOOR LEVEL OF FOURTH ROOR IS 3]'-0") CONCEALEOSPACES IBC ]18 AND NFPA 13 A. FIREBLOCKING: REQUIRED, BOTH VERTICAL ANO HORIZONTAL 10' INTERVALS BEHIND TRIM FINISHES. FIRE BLOCKING SHALL CONSIST OF ONE OF THE FOLLOWING: APPROVED NONCOMBUSTIBLE MAT2" OR (2) 1" WMBER W/BROKEN LAPJOINTS, 1 23/32" WOOD STRUCTURAL PANEL W/JOINTS BACKED BV 23132' STRUCTURAL PANEL OR 2% W MBER. 6. DR4FTSTOPPING IN FLOORS: PER IBC ]18.3. C. DRAFTSTOPPING IN ATTIQ PER IBC 11842. PENETRATIONS THROUGH FIRE RATED ASSEMBLIES A. REFER TO SECTION ]14 EXIT SIGNS 8 EMERGENCY LIGHTING EXIT SIGNS PROVIDED PER BC 1 �13 , INTERNAL BATTERV BACKUP. FLOOR-LEVEL EXIT SIGNS PROVIDED PER IBC 10132. MEANS OF EGRESS ILW MINATION AND EMERGENCV LIGHTING PROVIOED PER IBC 1008. ELEVATOR REQUIRE� TO MEET ASME Ai].1 STAIRA EXIT6 63 63 0.3" 160 48" 0.2" 160 32" STAIRA EXIT6 63 63 0.3" 160 48" 0.2" 160 32" SOUTH� � � NORTH RELEA5E0 FOR CONSTRUCTION Suhjec��o compliance with allregula�ions 04 S�a�e antl Local Codes City of Carmel , �{�n„� i,.�awa' � onrE: 03/19/20 SOUTH� � �NORTH ND FLOOR LIFE SAFETY PLAN = 1'-0" NORTH � � 7 � � TABULAR OCCUPANT LOAD, BOILDING 1- SOOTH (IBC 100042) FLOOR OCG TYPE AREA BFI FACTOR OCG LOA� (SAPERSOM (PERSONSI GROUND eUSMESS 3,202 SF 1I100 GROSS 32 STORAGE 40SF 1I300GR055 7 FIRST ASSEMBLV ]30SF 1/iSNET 49 BUSINESS 498SF 1/100GROSS 5 STORAGE 40 SF 1I300 GROSS 7 SECOND RESIDENTIAL 2,]�6SF 1/200GR055 14 STORAGE 40SF 1/300GR055 1 THIRD RESIDENTIAL 2,]O6SF 1/200GROSS 14 STORAGE 40SF 1/300GROSS 1 BUILDING TOTAL 178 EGRESSELEMENT SPACE AREA BUSINESS FUNCTIONOFSPACE 6OOOSF B OCCUPANCV OCCUPANTS SERVED �� �OO SO P CLASSIFICATION (REQUIRE�) NUMBER OF REQUIREO EGRESS W IDTH E%ITS PROVIDED ( � NUMBEROFOCCUPANTS OCCUPANTSSERVED � PROVIDEO) REQUIREO S.F. PER ( OCCUPANT REOUIRED ELEMENT WI�TH —•—•— iHOURRATED FIRE BARRIER ������� 2HOURRATED FIRE BARRIER ������� 2HOURRATED FIRE SEPARATION eEXIT SIGN - SEE y ELECTRICAL TRAVEL DENOTES EXIT DISTANCE� �� ROUTE =00'-6" ♦�� 1 � START DENOTES EXIT J POINT DISCHARGE SEMI-RECESSED PORTABLE FIRE FEC E%TINGUISHERCABINETWITH PORTABLE FlRE EXTWGUISHER PER NFPA ]2 AS SELECTED BV LOCAL FIRE MARSHALL. FE WALLMOUNTEDPORTABLEFIRE EXTINGUISHER PERNFPA]2AS SELECTED BV LOCAL FIRE MARSHALL. EXIT 7 02" 62 160 32" STAIR B 0.3" 62 160 48" EXIT 7 � 2° 62 160 32" STAIR B 0.3" 62 160 48" � 4 � 1 2 NORTH KEY PLAN � ��� � WOOL'L'PERT CMrtECTU0.E�nGINEEPIH6I4E0A1T11L 76351nteractive Way Suite 100 Indiana olis IN G p ' 46278 317.299.7500 FAX: 317.291.5805 novo�:: �y �7 U] C �:7 �9 �� � W � � O W � W 0 J J � � � � � 0 � ^>' W � �c C L (B U � � .� W U � O L � � � � � � � � 0 N N M � O � N V � U � � `o m c a � o c . d d � � � d m = U Dlssuances: Proi. No.: 074904 Date: 10/24/18 Sheet Name: SECOND AND THIRD FLOOR LIFE SAFETY PLANS LS1-102 � THIRD FLOOR LIFE�°�"�ET�W"`�LAN / u NORTH crei F � vv�^ _ �• n••