HVAC ABBREVIATION LEGEND
� SUPPLV OR OUTSIDE AIR DUCT UP � RADIUS RECTANGULAR ELBOW
� RETURNOREXHAUSTAIRDUCTUP � TT SUPPLVOROUTSIDEAIRROUND
(�W DUCTUP
� SUPPLYOROUTSIDEAIRDUCTDOWN �,T(` RETURNOREXHAUSTAIRROUND
�u� DUCTUP
� RETURNOREXHAUSTAIRDUCTDOWN � ROUNDDUCTDOWN
I�I SUPPLY/ OUTSIDE AIR DUCT OFFSET � ROUND OFFSET
I�I RETURNAIRDUCTOFFSET \ � ROUNDELBOW
\lfi
� MANUAL BALANQNG DAMPER �� ,( ROUND WYE
��-'
�DTS� DUALTEMPERATURESUPPLVPIPE t ,�7 UNION
�DTR� DUALTEMPERATURERETURNPIPE ���i�1 CALIBRATEDBALANCEVALVE
�
�DHW� OOMESTIC HOT WATER PIPE �� PRESSURE REGULATING VAVLE
�V� VENT PIPE l-�-t GLOBE VALVE nT�P
�G� NATURAL GAS PIPE H� GATE VAVLE �
�LPG� LIQUIDPROPANEGASPIPE �� STRAINERWITHBLOWDOWNVALVE �
�RL� REFRIGERAMLIpUI�PIPE �� STRAMER
�RS� REFRIGERANT SUCTION PIPE �� BLIND FLANGE
�
�RHG� REFRIGERANTHOTGASPIPE + 4 + MOTORIZED2-WAVVALVE
�LPS� LOWPRESSURESTEAMPIPE p �
2--i � MOTORIZED3-WAVVALVE
�MPS� MEDIUM PRESSURE STEAM PIPE
�HPS� HIGH PRESSURE STEAM PIPE �.�
PRESSURE RELIEF VALVE ��
�CR� CONDENSATE RETURN PIPE
�FW� FEED WATER PIPE � PRESSURE n THERMOMETER ��
� GAGE �`III�
t 'Y
DUCTWORK SYMBOL LEGEND T��
PIPE SYMBOL LEGEND SCHEMATIC SYMBOL LEGEND
�CHWS� CHILLED WATER SUPPLV PIPE �C� PIPE DOWN � MVIAV AIR VENT, MV-MANUAL VENT; AV-
�CHWR� CHILLE� WATER RETURN PIPE 2--�-t PIPE UP � AUTOMATIC VENT
�CWS� CONOENSERWATERSUPPLVPIPE r Y y TEEDOWN �
� AUTOMATIC 2-WAV CONTROL VALVE
�CWR� CONDENSERWATERRETURNPIPE � TEEUP
�DCW� DOMESTICCOLDWATERPIPE r PIPEBREAK(FORCLARITV) �
AUTOMATIC 3-WAV CONTROL VALVE
�HWS� HEATINGHOTWATERSl1PPLVPIPE �� CAPPEDPIPE
�HWR� HEATING HOT WATER RETURN PIPE r-�,T-� GAS SHUT-0FF VALVE
� AUTOMATIC FLOW CONTROLLER
�GLVS� ICE WATER SUPPLV PIPE ,�c� BALL VALVE
�GLVR� ICE WATER RETURN PIPE ����I�-t BUTTERFLV VALVE
�� CHECKVALVE
MOTORIZED DAMPER
� FIREDAMPER
� K I �, RECTANGULAR TO ROUND l
�du
�� RECTANGULARTRANSITION
�
� RECTANGULARBRANCHTAKEOFF
1 >
C� RECTANGULARDUCTTERMINATION
� ROUND DUCT TERMINATION
STANDARDRECTANGULARELeOW
I:I
DESIGN CRITERIA
�ENERAL DESIGN INFORMATION INDOOR DESIGN CONDITIONS
BUIL�ING STAIRWELL WINTER DRV BULB: 60.0°F
LOCATION: CARMEL, INDIANA
LATITUDB 3991 CORRIDORSANDTENANTROOMS
LONGITl10E' 86.13
ELEVATION: 853 WINTER DRV BULB: ]0.0°F
�UTDOOR DESIGN CONDITIONS wiNieR zHi: nnneieNr
SUMMER DRV BULB: 15.0°F
SUMMER DRV 91$°F (0.4% ASHRAE DESIGN SUMMER RH%: 60 o MAX
BULB: CONDITION)
SUMMER WET 15.0°F (0.4% ASHRAE DESIGN
au�a: coNoirioN�
WIMER DRV 2.6"F (99.6% ASHRAE DESIGN
BULB'. CONDITION)
RELEA5E0 FOR CONSTRUCTION
Suhjec� �o compliance with all regula�ions
04 S�a�e antl Local Codes
City of Carmel
,
�{�n„� i,.�a�'
\
onrE: 03/19/20
ANNOTATION SYMBOL LEGEND
QT THERMOSTATORTEMP.SENSOR //////��a���\\\
HO HUMIDISTAT � SECTION SVMBOL
H-100
SQ SWITCH
� KEVNOTE DESIGNATION RTU EQUIPMENT PLAN MARK
Q 12
POINT OF NEW CONNECTION
1-01 VAVTERMINALUNITMARK 4 DETAILSVMBOL
AHU4 EQUIPMENTMARK H400
8"e ROUNDDUCTSRE
24x12 RECTANGULAR DUCT SIZE
AIR DEVICE AND DUCT ACCESS. LEGEND
RETURN AIR GRILLE �� SUPPLY AIR DIFFUSER
L/�_ILJ' (HARDCONNECTION)
SUPPLVAIRDIFFUSERWITHREXIBLE RETURNOREXHAUSTGRILLE
RUNOUTANDDAMPER C (HARDCONNECTION)
�� SIDEWALLDIFFUSER � 14X74TRANSFEROPENINGINWALL
�� SUPPLYAIRDIFFUSER TRANSFEROPENINGINWALL
1 � 1 (HARD CONNECTION) �
�� RETURN OR EXH. GRILLE
1 � 1 (HARD CONNECTION)
�
REXIBLE CONNECTION
GAUGE, T-TEMPERATURE; P-PRESSURE
MANUAL BALANCE VALVE
PIPE REDUCER/INCREASER
PRESSURE REDUCING VALVE
SHUTOFFVALVE
COMBINATION BALANCE-SHUTOFF VAWE
TRIPLE �UTV VALVE;
SHUTOFFBALANCECHECK
SAFETV RELIEF VALVE
f I �IRECTION OF FLOW
PROJECT NOTES
CONTROLNOTES:
1. PROVIDE PROJECT SPECIFIC CONTROL SVSTEM MANUAL FOR THE BUILDING. THE MANUAL SHALL
CONTAIN A DIAGRAM OF THE W NTROL SVSTEM ARCHITECTURE. W IR W G DIAGRAMS AND A SEQUENCE
OF OPERATION. THE MANUAL SHALL ALSO INCLUDE AN 11 X i] ROOR PLAN INDICATING THE MAJOR
EQUIPMENT AND PANEL LOCATIONS. THE MANUAL SHALL BE BOUND IN A HARD BACK 3 RING BINDER
WITH DIVIDERS. BINDER SHALL BE LABELED "H.V.A.0 TEMPERATURE CONTROL MANUAL" AND INCLUDE
THE PROJECT NAME AS W ELL AS THE BUIL�ING NAME, NUMBER AND ADDRESS.
2. LABEL ALL CONTROL PANELS, ACTUATORS, SENSORS, ETC WITH 1/8" THICK PLASTIC LAMINATE SIGNS.
SEE DRAW INGS FOR LABEL AND LETTERING REQUIREMENTS. LABEL DESIGNATIONS SHALL BE
CONSISTENT WITH THE �RAWINGS, TEMPERATURE CONTROL SVSTEM MANUAL AND DIAGRAMS.
3. MOUNTWALLMOUNTEDTHERMOSTATS,TEMPERATURESENSORSANDCARBONMONOXIDESENSORS
4'-0" ABOVE FINISH FLOOR. DO NOT MOUNT THERMOSTATS OR TEMPERATURE SENSORS IN DIRECT
SUNLIGHT OR NEAR HEAT PRODUCING EQUIPMENT.
4. THE ELECTRICAL CONTR4CTOR SHALL PROVIDE ALL MOTOR STARTERS AND OISCONNECT SW ITCHES
FOR H.V.AG EQUIPMENT UNLESS THEV ARE MCLUDED WITH THE EQUIPMENTAS INDICATED ON THE
ORAWINGS AND M THE SPECIFICATIONS. COORDINATE STARTER REpUIREMENTS WITH THE
ELECTRICAL CONTRACTOR AND THE CONTRACTOR PRIOR TO ORDERING.
5. WHEREAUXILIARVCONTACTSAREREQUIREDINSTARTERSPROVIDEDBVTHEELECTRICAL
CONTRACTOR, THE MECHANICAL CONTRACTOR SHALL COOR�INATE THE QUANTITV AN� TVPE OF
CONTACTS W ITH THE EQ PRIOR TO PURCHASE.
6. THE ELECTRICAL CONTRACTOR SHALL PROVIDE CIRCUIT BREAKERS W THE ELECTRICAL PANELS THAT
ARE SPECIFlCALLY DEDICATED FOR THE TEMPERATURE CONTROL SYSTEM. COORDINATE THE
QUANTITV AND SIZES WITH THE CONTRACTOR. SEE ELECTRICAL DRAW INGS FOR LOCATION.
1. THE MECHANICAL CONTRACTOR SHALL PROVIDE ALL TEMPERATURE CONTROL SYSTEM W IRING AND
CON�UIT REGARDLESS OF VOLTAGE AS REQUIRE� TO PROVIDE THE SPECIFlED SEQUENCE OF
OPERATION OR SATISFV ANV MANUFACTURER REQUIREMENTS. POW ER AN� CONTROL W IRING AND
CONDUIT FOR VALVEACTUATORS, DAMPER ACTUATORS CARBON MONOXIDE SENSORS,
TEMPERATURE CONTROL PANELS, RELAYS, INDICATOR LIGHTS, REMOTE CONTROL PANELS, SOLENOID
VALVES AND OTHER SIMILAR DEVICES THAT ARE PART OF THE H V A.0 SVSTEM SHALL BE PROVIDED
BV THE MECHANICAL CONTRACTOR. SEE ELECTRICAL DRAW INGS FOR THE LOCATION OF CIRW IT
BREAKERS SPEQFICALLY DEDICATED FOR TEMPERATURE CONTROL SYSTEM COMPONENTS. ALL 120 V
CONTROL WIRING SHALL BE INSTALLE� IN CONDUIT. CONCEALED ABOVE CEILING PLENUM RATE� LOW
VOLTAGE (24 VOLTS OR LESS) CONTROL WIRING DOES NOT REQUIRE TO BE INSTALLED IN CONDUIT.
8. THE MECHANICAL CONTRACTOR SHALL PROVIDEALLCONTROLS, RELAVS, SENSORS, CONTROLLERS,
CONTROLTRANSFORMERS,CONTROLINTERFACECOMPONENTS,SOFTWARE,HARDWARE,
ACTUATORS, SW ITCHES AND ANV OTHER CONTROL COMPONENTS REQ W RED TO PROVIDE THE
SPECIFIED SEQUENCE OF OPERATIONS ON PLANS, TO WTEGRATE PROJECT CONTROLS AND SVSTEM,
AND TO MEET EQUIPMENT MANUFACTURER'S INSTALLATION AN� OPERATION REQUIREMENTS,
UNLE55 NOTEO OTHERW ISE ON PLANS.
9. IT SHALL BE THE MECHANICAL CONTRACTORS RESPONSIeILITV TO COORDINATE ALL TEMPERATURE
CONTROL SVSTEM REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR PRIOR TO THE PURCHASE
OR INSTALLATION OF ANV OF THE ELECTRICAL POWER OR TEMPERATl1RE CONTROL SVSTEM
COMPONENT.
10. ALL DAMPERS ON THE MLET OR OUTLET OF THE FAN SHALL BE OPEN PRIOR TO STARTING THE FAN.
PROVIDE ANY TIME DELAVS OR END SWITCHES AS REQUIRED.
11. IN PUBLIC AREAS PROVIDE CLEAR PLASTIC VENTED IMPACT RESISTANT LOCKABLE GUARDS ON ALL
WALL MOUNTED THERMOSTATS OR SENSORS WITH ADJUSTABLE SET-POINTS.
IDENTIFICATION:
1. PROVIDE PLASTIC LAMINATE IDENTIFICATION LABELS ON ALL EQUIPMENT SCHEDULE� ON THE
DRAWINGS. THE IDENTIRCATION SHALL BE CONSISTENT WITH THE PLANMARKS SHOW N ON THE
�RAWINGS AND THE BAS SVSTEM USER INTERFACE SEE DETAILS ON DRAW WGS REGARD WG COLOR,
SIZE, TEXT HEIGHT, ETC.
2. PROVIDE PLASTIC LAMINATE IDENTIFlCATION LABELS ON ALL TEMPERATURE CONTROL COMPONENTS
SUCH AS CONTROL PANELS, TEMPERATURE SENSORS, HUMIDITV SENSORS, ETC. THE I�ENTIFICATION
SHALL eE CONSISTENT W ITH THE PLANMARKS SHOWN ON THE DRAWINGS W HERE AVAILABLE AND
THE BAS SVSTEM USER INTERFACE SEE DETAILS ON DRAWINGS REGARDING COLOR, SRE, TEXT
HEIGHT, ETC.
3. PLASTIC LAMINATE SIGNS AND LABELS ON OUTDOOR EQUIPMENT SHALL BE RXED TO EQUIPMENT
WITH STAWLESS STEEL OR AW MINUM RIVETS OR STAWLE55 STEEL OR PLATED SCREWS.
4. CLEANE�UIPMENTANDPIPINGPRIORTOAFFlXINGADHESNETYPELABELSANDSIGNS.
PROJECT NOTES
GENERAL:
1. WSTALL THE H.V.A.G SYSTEM AS INDICATED IN ACCOR�ANCE WITH ALL STATE ANO LOCAL
CODES.
2 COORDINATEALLWORKWITHOTHERTRADES.REWORKOFPIPING,DUCTWORK,EQUIPMENT
LOCATION, WNDUIT. ETQ AS A RESULT OF POOR PLANNWG. COORDINATION OR SCHEDULING
SHALL BE THE RESPONSIBILITV OF THE INVOLVED CONTRACTORS. NOTIFV THE
ARCHITECTIENGINEER OF ANV CONFLICTS PRIOR TO START OF WORK.
3. THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF ANV
FRAMING REVISIONS, EQUIPMENT LOCATIONS, AD�ITION OF CONTROLS, ELECTRICAL CIRCUITING
REVISIONS, ETG THAT RESULT FROM USMG EQUIPMENT OTHER THAN THOSE INDICATED ON
THE DRAW INGS. APPROVAL OF THE SHOP DRAW INGS BV THE ARCHITECTIENGMEER W ILL NOT
WAIVE THE CONTRACTOR OF THIS RESPONSIBILITV.
4. THE MECHANICAL CONTRACTOR SHALL HAVE THE RNAL RESPONSIBILITV FOR SYSTEM START
UP, TRAINING, WARRANTY AND Tl1RN OVER TO THE OW NER. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR INSTRUCTING THE OWNER ON ANY ROUTINE MAINTENANCE REQUIRED
DURING THE WARRANTY PERIOD.
5. ALL ITEMS INCLUDED ON THESE �RAWINGS AND THE SPECIFICATIONS SHALL BE INCLUDED IN
THE CONTRACTORS BID. ANV ITEMS THAT ARE UNCLEAR OR FOUND TO BE INCORRECT BV THE
CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECTIENGINEER PRIOR TO
THE BID DUE DATE. EXCLUSIONS OF W ORK FROM THE BID ARE NOT ACCEPTABLE.
6. ALL WORK INDICATED ON THE MECHANICAL �RAWINGS SHALL BE PROVIDED BV THE
MECHANICAL CONTRACTOR UNLESS SPECIFICALLV NOTED OTHERWISE.
]. THEMECHANICALCONTRACTORSHALLPROVIDEALLFIRESTOPPINGFORDUCTANDPIPE
PENETRATIONS THAT PENETRATE FIRE RATED ASSEMBLIES. SEE ARCHITECTURAL DRAW INGS
OR REFER TO THE O W NERS RECORD DRAW INGS FOR LOCATIONS OF RRE RATED ASSEMBLIES.
ALL FLOOR PENETRATIONS SHALL BE FIRESTOPPED AND SEALED WATER TIGHT WITH A FLEXBLE
SEALANT. INSTALL PER MFG. RECOMMENDATIONS.
8. THE MECHANICAL CONTRACTOR SHALL COORDINATE ANV ROOF PATCHING FOR ANY
MECHANICAL ROOF PENETRATIONS NOT SPEGFlCALLV IDENTIFIED ON THE ARCHITECTURAL
DRAWINGS. ALL PATCHING SHALL BE PROVIDED BV GENERAL CONTRACTOR AND BE
PERFORME� IN A MANNER CONSISTENT WITH THE ROOF SVSTEMS CURRENT WARRANTV
RE�UIREMENTSAND MANUFACTURERSRECOMMENDATIONS.
9. THE MECHANICAL CONTRACTOR SHALL NOT PERFORM ANV WELDING OR TORCH Cl1TTING
OPERATIONS W ITHIN THE OCCUPIED BUILDING W ITHOUT OBTAINING PERMISSION OR A BURN
PERMIT FROM THE OW NER.
DUCTWORK-GENERAL:
1. ALL DUCTWORK SHALL BE CONSTRUCTED, INSTALLED AND SUPPORTED PER THE LATEST
VERSION OF THE S.M.A.C.N.A. HN.A.G DUCT CONSTRUCTION STANDARDS. UNLE55 SPECIFlED
MORE STRINGENTLV W THESE CONSTRUCTION DOCl1MENTS.
2 COORDINATION OF Ol1CT SVSTEM INSTALLATION WITH OTHER TRADES SHALL BE PERFORMED
PRIOR TO THE FABRICATION OF ANV DUCTWORK. VERIFV DUCT CLEARANCES PRIOR TO
FABRICATION. NOTIFV THE ARCHITECT/ENGINEER OF ANV CONFLICTS THAT RE�UIRE
DIMENSIONAL CHANGES OR REQUIRE MAJOR RELOCATION OF DUCTWORK.
3. ALL DUCTWORK SHALL BE SUPPORTED FROM ROOF OR ROOR STRUCTURE ABOVE DUCTWORK
SHALL NOT LAY ON TOP OF CEILING OR LIGHT FIXTl1RE5.
4. ALL DUCTWORK SRES SHOW N ARE EXTERNAL DIMENSIONS. ALLOWANCE HAS BEEN MADE FOR
1" DUCTLMER W HERE AND IF REQUIRED.
5. RECTANGULAR DUCTNORK SHALL BE SUPPORTED PER THE S.M.A.GN.A. STANDARDSAND AT
EACH CHANGE IN DIRECTION.
EQUIPMENT-GENERAL
1. THE H V AA. EpUIPMENT AND SVSTEM SHALL NOT BE USED TO DURING CONSTRUCTION. THE
WARRANTY PERIOD SHALL NOT BEGIN UNTIL SUBSTANTIAL COMPLETION. THE CONTRACTOR
SHALL EXTEND THE EOUIPMENT WARRANTV PERIOD AS NECESSARY W HEN EOUIPMENT IS USED
AFTER INITIAL START UP AND PRIOR TO SUBSTANTIAL COMPLETION.
���
�
WOOLPERT
10.W IiERURElEN6dEERIXGI4E03P1iILL
76351nterective Way
Suite 100
G Indianapolis, IN
462%8
317.299.7500
FAX: 317.291.5805
novo�::
�y
E
L
�
�:7
���
� uo. pEiiucnaei
•: __
o,�`, SL.TCC�
u
�
�`
W
�
�
O
�
W
�
�
U �
J•
J �
- W �
�-�+
� V �
�
� � �
�
m
0 O a
c
L �
� � o
W � O
� �
� m a
A` �% U c
� W � `o m
ca
C � � o �
L _ U _
N N
U�--���
�
m - U
0 Issuances:
Proi. No.: 074904
Date: 10/24/18
Sheet Name:
HVAC LEGEND AND
NOTES
M 1-001