O DRAWING NOTES O DRAWING NOTES
1 OUTSIDE AIR DUCT TO BE ROUTED ABOVE 8 12" X 6" TRANSFER DUCT LOCATED ABOVE
TYPICAL UNIT CEILING TO CONNECT TO CEILING. PROVIDE FIRE DAMPER AT WALL
RETURN AIR DUCT FOR AIR HANDLER. PENETR4TION.
2 PROVIDE 12X12 ACCESS DOOR IN CEILING 9 PROVIDE DUCT EXPANSION COMPENSATOR
FOR DAMPER ACCESS. AT 3" BUILDING EXPANSION JOINT.
3 PROVIDE MANUAL BALANCING DAMPERS AT 10 EXTEND 2" PVC EXHAUST VENT IN WALL
ALL AIR DEVICES. PROVIDE RADIATION FROM RINNAI TANKLESS WATER HEATER TO
DAMPER (TYPICAL) ROOF AND TERMINATE WITH VERTICAL
4 PROVIDE 10X8 RUSKIN WALL LOUVER WITH TERMINATION KIT. INSTALL PER
GRAVITY BACK DRAFT DAMPER AT OUTDOOR MANUFACTURER'S RECOMMENDATIONS.
AIR INTAKE. 11 EXTEND 2" PVC COMBUSTION AIR PIPE FROM
5 PROVIDE CLEAR LOCKABLE BOX FOR RINNAI TANKLESS WATER HEATER TO LOW
THERMOSTAT. PROFILE WALL TERMINATION KIT. INSTALL
6 PROVIDE MINIMUM 12" BASE SUPPORT TO PER MANUFACTURER'S RECOMMENDATIONS.
ALLOW CONDENSATE TO DRAIN TO JANITOR'S 12 2" PVC VENT IN WALL FROM GAS FIRED
SINK. EXTEND CONDENSATE DRAIN (FULL WATER HEATER BELOW.
SIZE) TO JANITOR'S SINK. INSTALL PER
MANUFACTURER'S RECOMMENDATIONS.
7 OUTSIDE AIR VENTILATION DUCT. PROVIDE
24V AUTOMATIC DAMPER INTERLOCKED TO
UNIT FAN. BALANCE TO AIRFLOW INDICATED.
M1401 � M1401
��
� �,/
�
�
i
0
� wa•a ��u o
200 CFM �
D-�2v12 �2z�
125 CFM
� ���� j ,
LJ
� � �
W
K
4
� �o'�_ ', ry. M1-401
n fj
� .� .... . _ .. J
/ A TVP.
4
5
n THIRD FLOOR PLAN - HVAC �QNORTH
U sisz„_,,_o„
z u
�M�
C-1o"m �p�i
200 CFM �
RELEA5E0 FOR CONSTRUCTION
Suhjec��o compliance with allregula�ions
04 S�a�e antl Local Codes
City of Carmel
,
�{�n„� i,.�a�'
\
onrE: 03/19/20
3� �{ .
M1-001
�� .�
�
'� _ � �3 �� � B
Mi-401' Mi-401
� ,'
)�_ � �
�
i
0
� � o� �
�
6�
Mi 401j
��
6�
, Mi 401j
�i
�cJ �
8
� �
�
, �J
(� 3 �
II M1-401�
II �
N
�I�
� SECOND FLOOR PLAN - HVAC mNORTH
3/32' - 1'-0' / �
� � �
Mi-401 I Mi-401
\� U
�
Ci
� �
� �
� o � �
� .
..... I il _. ,^
oio-e �m
200 CFM
�Mi-4 1 i 'l Mi-4 1
�
� /C
�
�� ��,. . 1 .. ,.
.�..Ir"_II i il ... .. .. .
1
Mi-401
� �
���
�
WOOLPERT
10.W IiERURElEN6dEERIXGI4E03P1iILL
76351nterective Way
Suite 100
G Indianapolis, IN
46278
317.299.7500
FAX: 317.291.5805
novo�::
F
E
� uo. pEiiucnaei
•: ,
o,�`, SL.TCC�
�
�
W
D �
�
O
W
^%,
— W
�
�
U �
C J ��
J �
W �
a--�
� V �
A �
� v . �
C
m
0 O �
— � L �
� O
� �o
0 �
� m a
w` � U c
� W � `o m
�a
C � � o �
L � N N
U�--���
�
B m - U
0 Issuances:
Proi. No.: 074904
Date: 10/24/18
A Sheet Name:
HVAC SECOND AND
THIRD FLOOR PLAN
M1-102