HomeMy WebLinkAboutM1-103-HVAC-ROOF-HVAC-PLAN-Rev.0,
UNITS 81-Bi
REFRIGERANT
PIPING �
CU-3 � �
CU-3 • �
T�P CU-3
4 3 2
7
UNITS Bi-Ai
REFRIGERANT PIPING
2 3 4
TYP
CU-0
CU3
�' CU-0 CU3
�' CU-0 CU-3
8
O
1
2
3
4
5
6
7
���
�
WOOLPERT
10.W IiERURElEN6dEERIXGI4E03P1iILL
76351nterective Way
Suite 100
G Indianapolis, IN
46278
317.299.7500
FAX: 317.291.5805
novo�::
li
E
v
a�e
Z
m
K
m
�
�
J
a
S
�
c
a
�
m
O
v
r
ro
K
E
�
c
U
0
a
uNirs si-ca�
REFRIGERANT
PIPING
]
CU3 • • CU3
TVP — —
4 3 2
�
HP-1
I
`a
(1) 81-A3 UNIT (3) 81-A1 UNIT
REFRIGERANT PIPWG
4 3 2
qp� �T�P CU-1
� Cll-1 � �
CU-1
GRV-2 6 5 •
CU-0 �
3
C!
UNITS 81-A1
REFRIGERANTPIPWG UNIT5B1-Bi
REFRIGERANT PIPING
2 3 J
CU4 TVP 4 3 2
� TVP CU3
CU-0
CU3 • �
�' CU-1
CU3 �'
�' CU-1 �
CU-3 �
UNITSBi-A2 UNITS67-Ai
REFRIGERANTPIPING REFRIGERANTPIPING 1��`�i\
\
1 CU-1 � ,���\�� CU-1
w
cu-i cw
Typ CU-1 � � CU-0
6 3 2 TVP CU-0 CU-0 TVP
4 3 2 2 3 4
CU3 � CU-3
TVP
4 3 2 �
UNITS 81-C3
REFRIGERANT
PIPING
RELEA5E0 FOR CONSTRUCTION
Suhjec��o compliance with allregula�ions
04 S�a�e antl Local Codes
City of Carmel
,
�{�n„� i,.�a�'
\
onrE: 03/19 20
UNITS Bi-Bi
REFRIGERANTPIPING �
4 3 2
TVP
CU3 •
CU3 �'
CU-3 �
;7
UNITS Bi-81
REFRIGERANT PIPING
2 3 4
CU3 CU3 TV7
�. �. . CU-3
�' CU3
7 ]
� CU3
/1
UNITS Bi-Ai
REFRIGERANT PIPING
4 3 2
T�P CU-1 CU-0
CU-1 � � �
CU-1 �
CU-1 �
UNITS Bi-A1 UNITS 81-Bi (2)UNITS B1-A1 (1) UNITS B1$1
REFRIGERANT REFRIGERANT . . REFRIGERANTPIPING (2�UNIT561-Ai
PIPING PIPING � ^ � REFRIGERANT
� CU 1 CU.9 //� �) � �' CU3 � PIPWG
/
� � � cu-i � • cu i
O ��-� TVP CU 3• CU-1 TVP �� � TVP
CU-0 T�P CU-3
4 3 2 2 3 4 2 3 4
2 3 4
______..._ ____________ �
n OVERALL ROOF HVAC PLAN %�NORTH
3/32�� _ ��_���
UNITS Bi-Bi
REFRIGERANT PIPING
2 3 4
CU3 TV7
�. . CU-3
�' CU3
� CU3
67
DRAWING NOTES
PROVIDE SPLIT SYSTEM FOR HOISTWAY
CONDITIONING. INDOOR UNIT SHALL BE WALL
MOUNTED WITHIN HOISTWAY. LOCATION
SHALL BE FIELD COORDINATED TO NOT
OBSTRUCT ANY ELEVATOR CLEARANCES OR
REQUIREMENTS.
ROUTE REFRIGERANT PIPING TO INDOOR
UNITS PER MANUFACTURER'S
RECOMMENDATIONS.
CONDENSING UNIT MOUNTED ON EQUIPMENT
SUPPORT RAIL. REFER TO DETAIL #11 ON
SHEET M-501.
PROVIDE PIPE CURB ASSEMBLY FOR
ROUTING CONDENSING UNIT PIPING
THROUGH ROOF. PROVIDE PIPE CURB FOR
EACH CLUSTER OF CONDENSING UNITS. SEE
DETAIL#6,SHEET M-501
PROVIDE VENTILATOR (WITH A MOTORIZED
LOW LEAKAGE DAMPER) ON ROOF OF
ELEVATOR SHAFT. THE DAMPER WILL FAIL
"OPEN" (DUE TO LOSS OF POWER) AND WILL
BE TIED INTO THE FIRE ALARM SYSTEM. FIRE
OR SMOKE WILL OPEN THE DAMPER AND
ALARM THE FIRE ALARM SYSTEM..
VENTILATION AIR DUCT THROUGH ROOF.
TERMINATE WITH WEATHER HOOD WITH
BIRDSCREEN.
RINNAI TANKLESS WATER HEATER VERTICAL
TERMINATION KIT FOR EACH HEATER.
INSTALL PER MANUFACTURER'S
RECOMMENDATIONS.
(1) Bi-Ci ADA
(3) 81-Ci UNIT
REFRIGERANT
PIPING
� AHU-5CORRI�OR
REFRIGERANT PIPWG
UNITS81-A1 W-5� � � �i Cl
UNITSBi-A1 REFRIGERANT CU-5 CU-5
REFRIGERANT � PIPING
PIPING �. CU4 � UNITS 61-02
CU-1 � ]
CU3 REFRIGERANT
� PIPING
CU-1 • � �' ' p�_� �
T�P Typ CU3 •
GU-� CU-1
4 3 Z 2 3 4 CU3
TVP
4 3 2
.
�
�
� uo. pEiiucnaei
.: ,
o,�`, SL.TCC�
��
�
W
�
�
W
^�,
W
�
�
U �
J •
J �
�U
Q �
0^, O
W �
i
�
� �
L �
U�
�
�
N
C
N
rn
c
m
a
c
N
�
N M
�o
� m a
� U c
� `o m
�a
� o �
� N N
'� � �
�
m - U
0 Issuances:
Proi. No.: 074904
Date: 10/24/18
A Sheet Name:
HVAC ROOF HVAC
PLAN
M1-103