HomeMy WebLinkAboutM1-501-HVAC-DETAILS-Rev.0, 3 z 9 WEIGHTED BACK-DRAFT DAMP FOR AIR RELIEF GRILLE (REFER TO PL FOR SIZE AND TVPE) SHEET METALSLEEVI DOG HOUSE FOR REFRIGERANT PIING NTS ED CEILING ITION ��� � WOOLPERT 10.W IiERURElEN6dEERIXGI4E03P1iILL 76351nterective Way Suite 100 G Indianapolis, IN 46278 317.299.7500 FAX: 317.291.5805 novo�:: � uo. pEiiucnaei •: , o,�`, SL.TCC� Z � K m � � J a _ U W � � a m O rn r ro K e � � � g o a a O � AIR RELIEF DETAIL NTS SIDEWALL EXHAUST FAN NTS � VALL LOWER. SEAL ALL ,ROUND WITH SILICONE. EXTERIOR WALL OKEVED NOTES: 1. SIDEWALLEXHAUSTFANWITHGRILLE 2. STUD WALL 3. OUTLETFLANGE 4. BACK�RAFTORMOTOROPERATEDDAMPER (SEE SCHEDULE SPECS) 5. 4" METAL EXHAUST DUCT UP INTO CEILING SPACE AND OUT SIDEW ALL W ITH LO W ER. � SUPPLV,RETURP EXHAUSTDUCT BREAK-AWAV DUCT CONNECTI ACCESS PANEL W ITH LATCHES. PANEL SHALL BE RATED FOR STATIC PRESSURE OF �UCT SVSTEM. PROVIDE MSULATED ACCESS PANELS FOR INSULATE� OR LINED DUCTSVSTEMS. 24 GAUGE GALV. STEEL BLADES. 165 DEGREE FUSIBLE LINK 1 S"X1.5"X1/8" STEEL ANGLE BOLTED TO SLEEVE. GALV.STEELSLEEVE METAL GAUGE TO MATCH DUCT FLOOR SLAB SVSTEM.24 GAUGE MINIMUM. UL CLASSIFIED 1-1/2 HOUR 20 GAUGE GALV. STEEL FRAME FIRE �AMPER FOR STATIC SVSTEMS n HORIZONTAL FIRE/SMOKE DAMPER DETAIL U NTS GALVANRED STEEL SLEEVE. METAL GAUGE TO MATCH DUCT SVSTEM.24GAUGEMINIMUM. - 24 GAUGE GALVAN2ED STEELBLADES FUSIBLE LINK 1.5" X L5" X 1/8" STEEL ANGLE BOLTED TO SLEEVE BREAK-AWAY DUCT CONNECTION 20 GAUGE STEEL BLADES J �/LL � ACCESS PANEL W ITH LATCHES. PANEL SHALL BE RATED FOR STATIC PRESSURE UL CLASSIFIE� 14/2 HOUR FIRE OF DUCT SYSTEM. PROVIDE INSULATED DAMPER FOR STATIC SVSTEMS ACCESS PANELS FOR INSULATED OR LINED DUCT SVSTEMS. 2 HOUR FIRE RATED PARTITION. SEE ARCHITECTURAL DRAWINGS FOR LOCATIONS. nTYPE B VERTICAL FIRE DAMPER DETAIL U Nrs u1°" BRAMEC 400]BLK SCRE W UP FOOT AT EA. CORNER, INVERTED AND FASTENED TO UNIT DNERSITECH MP-4C ANTI-VIBRATION PADS ADHERED TO BOTTOM OF FOOT � TPO SLIP SHEET PROTECTION LAYER AT EA. SUPPORT O60 TPO FULLV ADHERED MEMBRANE ROOFING OVER 1/2" FIBER BD.OVER 3l4" CDX PLVWOOD SHEATHING ON ENGINEERED WOOD TRUSS CONSTRUCTION NOTE: RooFOE�K A CONDENSING UNITS MUST BE ANCHORED TO ROOF TO RESIST W IND FORCES - ANCHORAGE SHALL BE COORDINATED AN� SPEGFIE� BV MECH. CONTRACTORAND E�UIPMENT SUPPLIER. RELEA5E0 FOR CONSTRUCTI�N �UPPORT RAIL Suhjec� �o compliance with all regula�ions 04 S�a�e antl Local Codes City of Carmel , �{�n„� i,.�a�' \ onrE: 03/19/20 4 °NT OR INTAKE .E55 STEEL BAND CLAMP �LE RUBBER OR 2ENE BOOT LE SEALANT _ES VENT THRU ROOF DETAIL NTS � CEILING SLEEVE: MINIMU GAUGE FOR DAMPERS N EXCEEDING 26"X24" 16 G, FOR LARGER SIZES '�LES 1-112" X 1-1/2" X 1/8" MUM; FASTENED TO SLEEVE AS !UIRE� BV LLL LABEL; ANGLES TO .RLAP MASONRY OPENING MINIMUM 1" 7AMPER NOTE CONNECT SLEEVE TO DIFFL COLLAR ALL SIDES OF DEVI( AS REQUIRED BY U.L LABEL � REFER TO STRI "'T"""' DRAW INGS FOF FASTEN WITH MASONRY ANCI EXHAUSTFAN FANENCLOSURE � ALUMINUM BACKDRAFTDAMPER WITH COUNTER BALANCE � WALL LOIIVER SIMILAR TO RUSKIN ELF3�50. REFER TO SPEqRCATIONS. SHEET METAL SLEEVE EXTERIOR WALL EXHAUST FAN WITH LOUVER DETAIL NTS FLEXIBLE DUCT. MAXIMUM LENGTH 5'-0". MINIMIZE ABRUPT OR SHORT RADIUS TURNS.�TENANTROOMSEXEMPTFROM MA%LENGTH RE�UIREMENT) STRAP HANGERS (TVP) � 7 PREMANUFACTURED (ALUMINUM PAINTED GALVANIZED STEEL) HOO� 14" HIGH 18 GAUGE BIRD SCREEN GALVANRED STEEL WELDE� CURB FILL GAPS W ITH � � � � � � � EXPANDABLE FOAM GRAVITV BACKORAFf SEALANT DAMPER W ITH BLADE SEALS,SHAFfSEALS DISCHARGE DUCT AND COUNTER BALANCE n ROOF MOUNTED EXHAUST HOOD U NTS NOTE: MECHANICAL CONTRACTOR TO COORDINATE VTR � � EXACT TRUSS LOCATION AND/OR TRU55 �UANTITV W ITH TRUSS SUPPUER. SUPPLY AIR PLENUM ON TOP OF HVAC UNIT TO EXTENO UP INTO TRUSS SPACE, NO (� TRUSSES TO BE LOCATED ABOVE SUPPLV AIR � � PLENUM iP' FLEX DUCT i6" SUPPLV AIR PLENUM 2" PVC EXHAUST � IN WALL � w � CLOSET � WALL � Q 2" PVC INTAKE, SEE PLAN AND SCHEDULE — A-COIL (SEE SCHEDUL �, 14'k21"x2T'T 1 RINNAI w BLOWER `O (SEE SCHEDULE) � U SIDE �` RLTER i RACK d M 14'k22"x34"T o w z w w U a N 2" CLEARANCE z m T � '� a I � RINNAI HEATER (SEE SCHEDULE) I N 18.5"x26A"x114•' 12" CLEARANCE MECHANICAL CLOSET SECTION NTS PLENUM CLOSET WALL � � U ¢ � U a � PLUMBING EXPANSION TANK REFRIGERANT LINES TO CONDENSING UNIT RINNAI HVDRONIC AIR HANDLER PUMP WITH MTEGRAL ROW CHECK VALVE QFC) EVAPORATOR COIL I�I 8 HVDRONIC HEATING COIL � AIRSEPARATOR VALVE STUBS FROM TANKLESS WATER HEATER BV P.C. FLOW SENSOR BLOWERASSEMBLV CONTROLBOX THERMOSTAT NOTE: ALL PIPING TO BE POTABLE GRA�E COPPER PIPING AND BRASS APPURTENANCES ONLV. TYPICAL PIPING ARRANGEMENT FOR DIRECT SPACE HEATING NTS CEILING/AIR DEVICE MOUNTED FIRE DAMPER DETAIL NTS � KEVED NOTES'. 1. P' x 4" TREATED NAILER 2. ANCHORTODECK a i°uNEo 4. OPENINGTHRUROOF. SIZEBASEDONPIPING INSTALLATION REQUIREMENTS. 5. DOUBLE WALL 12" INSULATED CAP 6. 20 GAUGE GALV. SHEET METAL. ]. CANT REQUIRED FOR BUILT-UP ROORNG. DELETE CANT FOR ANV NON BUILT-UP ROOFING SVSTEM AND FLASH TO BELOW CURB CAP. 8. SECURE CAP TO BASE W ITH 1 SCREW PER SIDE. 9. 24 GAUGE GALV. SHEET METAL THIMBLE FOR PIPE PASSAGE CAULKTHIMBLE AT DOG HOUSE AND AT PIPE PENETRATION. 6C11J�lILN� ACCESSIBLE CEILING PROVIDE INSULATED ROUND PIPE WHERE ENTIRE RUNOUT EXCEEDS 5'-0" IN LENGTH. SEE DUCTSCHEDULE ON DRAWINGS FOR INSULATION TVPE AND THICKNESS. VOLUME �AMPER WITH LOCKING QUAORANT AN� POSRION INpICATOR DUCT COLLAR � SEAL CONNECTION BETWEEN THE DUCT COLLAR AND THE DUCTNORK � CEILING MOUNTED AIR DEVICE OTE: SEAL ENDS OF FLEXBLE DUCT W ITH TAPE AND SEAL JOINTS BETWEEN THE DUCT WLLAR AND THE MAIN DUCT. DAMPER pl1A�RANT SHALL PENETRATE THE INSULATION AND SUFFICIENT SPACE SHALL BE ALLOW ED FOR OPERATION. SUPPLY OR EXHAUST RUNOUT DETAIL NTS F �� D C B � �� �^` W � � O W W � � U � J • J � � K a--� � V � A � � v . � c Q O � 0 � ^, � N V! � ❑ W � O � � � m a � U � aN � c �� �a C � � o � L � N N U �"' � �� N m - U 0 Issuances: Proi. No.: 074904 Date: 10124118 A Sheet Name: HVAC DETAILS M 1-501