Loading...
HomeMy WebLinkAboutP1-001-LEGEND,-DETAILS,-AND-SCHEDULES-Rev.0v � Z ro � m � � J a 2 U W � m � a � m rn r m K E � c N O a` , 2 3 � 7 � EQUIPMENT SCHEDULE SCHEDULENOTES: 1. PROVIDEROUGH-IN. 2 INSTALLALL"LOOSE"COMPONENTS 3. PROVIDE ALL NECESSARV SUPPLIES, STOPS, TRAPS, DRAINS. Y 4. MAKE ALL FlNAL CONNECTIONS. � Q � DESCRIPTION AL-0 ALARM BELL: POTTER ROEMER # PB1208-8". ELECTRIC, 99 DB SOUND EMISSION, W IRING BV ELECTRICAL CONTR4CTOR. ET-1 EXPANSION TANK: WATTS # PLLS POTABLE WATER 2.1 GALLON TANK (NON ASME) FDC-0 RRE �EPARTMENT CONNECTION: POTTER ROEMER # 5033 TWO WAY, TOP OUTLET, LETTERED "AUTO SPKR. STANDPIPE" F�VC-1 FIRE DEPARTMENT VALVE CABINET' POTTER ROEMER # FRC1810 RECESSED, AWMINUM FRQME, TVPE A DOOR 2 VT' FIRE �EPARTMENT VALVE. FS FLOW SW ITCH: POTTER ROEMER, VSR SERIES VANE TYPE W ITH RETARD FEATURE REFi FlRE RATE� REFRIGERATOR WATER VALVE BOX:OATEVk38492, CRIMP PEX CONNECTION, WATER HAMMERARRESTOR REF-2 REFRIGERATOR WATER VALVE BOX'. OATEY #386�4, CRIMP PEX CONNECTION, WATER HAMMER ARRESTOR RHVD-1 ROOF HVDRANT: WOODFORD #SFH-MS FREEZLESS ROOF HVDRANT SP-1 SUMP PUMP- ELEVATOR 50 GPM @ 75 FT. HD., ZOELLER #139 FLOW MATE, BRONZE CONSTRUCTION, UN6CHECK VALVE. TS TAMPER SWITCH: POTTER ROEMER, #OSVSU SERIES OR EQUNALENT FOR SUPERVISION OF ALL COMPONENTS WH� ELECTRICWATERHEATER'.40GAL,LOWBOV,TW04.SKWELEMENTS,208VOLT,iPHASELOCHINVAR#KSA040KJ.SETUPPERANDLOWER THERMOSTATS AT 120°F. W HDP-0 WATER HEATER DRAIN PAN: OATEY #341�4 AW MINUM DRAIN PAN. EXTEND �RAIN PAN�ISCHARGE TO ROOR DRAM FOR INDIRECT DISCHARGE. WHVD-0 WALLHVDRANT: WOODFORD#Bfi5 pyM_p DOMESTICWATERMETER:NWPSERVICESCORPORATION#iNMT-W4METERWITHPULSEUNIT,TEHAMNBASICMDTTRANSMITTER.ANVWIRING FROM INDIVIOUAL METERS TO CENTRAL POINT OF MONITORING SHALL BE PROVI�ED BY THE ELECTRICAL CONTRACTOR. WSH-0 RRERATEDWASHINGMACHMEOUTLETBOX:OATEV#38484,CRIMPPEXCONNECTIONS,2"DRAIN,WATERHAMMERARRESTORS. WSH-2 WASHINGMACHMEOUTLETBOX:OATEY#38105,CRIMPPEXCONNECTIONS,2"DRAIN,WATERHAMMERARRESTORS. DRAIN SCHEDULE MANUFACTURER T�PE BODV OUTLET STRAINER/GRATE TOP FINISH ADD. FEATURE ZURN/OATEV w w w w � a �n Y `~' � o y N� a� w z a� w � �' 'a o " a °� m o m w LL � a cYi �� g� az Q tt 3 � rn � O u~i w vNi w� w� K��(� o m v~i z r a rc p o a �� v� z � F w z� Y r o z o i . tt w a�w c o w rn a U a w k w w � U z �n a U o x¢ 2 w= G � O d' Q Q d' > F N O�'_� � � O W J� U Q U r Z � m W J W� K W U C A T A L O G N O S. u¢¢ 3 U m u vi vi m vi v� ¢� o K� x z U¢ v� ¢� o v� ¢ m� r v� ln FD-0 OATEV 43569 • • 2" • 4" • • 2 FD-2 ZURNZ400-SBZ • • 3" • 5" • • 2 DSC-1 OVERFLOW DRAIN OUTLET � � � � COVER Z199 �C RD-1 ROOF DRAIN Z10�-W2 • • 4" • 15" • • • Qp � OVERFLOW ROOF DRAW � � 4, � 15„ � � � Z101-W4 NOTES: 1. SIZEASREOUIRED 2 PROVIDEORAINTRAPSEALER,SURESEALORAPPROVEDEQUAL. 1. 2 3. 4. 5. 6. ] 8. 9 10. 11. 72. 13. GENERAL NOTES (PLUMBING) REFER TO SCHEDULES, DETAILS AND DIAGRAMS FOR PIPING, PIPE SIZES NOT INDICATED ON THE FLOOR PLANS. PWMBING CONTRACTOR SHALL FURNISH ANO WSTALLTHE PWMBING SVSTEM AS PER THE STATE PLUMBING CODE AND APPLICABLE LOCAL CODES. CONTRACTOR SHALL NOT SCALE THE CONTRACT DOCUMENTS FOR THE PURPOSE OF OBTAINING FINAL MEASUREMENTS. COORDINATE WITH ARCHITECTURAL PLANS AND ACTUAL FlELD CONDITIONS. PLANS TO BE CONSIDERED DIAGRAMMATIC AND ALONG W ITH SPECIFlCATIONS, RERECT A MINIMUM ACCEPTABLE STANDARD. ALL WORK SHALL CONFORM TO THE STATE PLUMBMG CODE AND THE AMERICANS WITH DISABILITIES ACT GUIDELINES. PLUMBMG CONTRACTOR SHALL SECUftE AND PAV FOR ALL FEES AN� PEftMITS ASSOCIATED WITH HIS PORTION OFTHE WORK. PLUMBMG W NTRACTOR SHALL COORDINATE ALL ASPECTS OF W ORK W ITH OTHER TRADES PRIOR TO AND DURING CONSTRUCTION/INSTALLATION. W HEN A CON FLICT BETW EEN PLANS AND SPECIFICATIONS OR NOTES OCCURS. THE ENGMEER SHALL DECIDE WHICH GOVERNS. GENERALLV, THE MORE RESTRICTNE, MORE SPEQRC. OR STRICTER PROVISION SHALL GOVERN. IF ANV DISCREPANQES ARE DISCOVERED ON THE PLANS OR BETWEEN THE PLANS AND THE SPECIFICATIONS, THE CONTRACTOR SHALL NOTIFV THE GENERAL WNTRACTOR AND OBTAIN CLAPoFlCATION OF THE INTENT FROM THE ENGWEER PRIOR TO CONSTRUCTION OR INSTALLATION OF PROPOSE�IMPROVEMENTS. REFER TO ARCHITECTURAL DRAW INGS AND INTERIOR ELEVATIONS FOR EXACT LOCATIONS, FIXTURE HEIGHTS AND ACCESSIBILITV REOUIREMENTS. PROVIDE CLEANOUTS OR W ALL CLEANOUTS W HERE IN�ICATED ON PLANS. MINIMUM NATURAL GAS PIPING SIZE SHALL BE 14/4" UNLESS OTHERWISE NOTED. ALL PIPING SHALL BE SLOPED AT A MINIMUM OF 1I8" SLOPE. ALL PIPING SHOWN ON FIRST THROUGH FOURTH FLOOR PLANS ISABOVE CEILING, BELO W FLOOR ABOVE. ACCESS PANELS PROVIDED BY THE PLUMBING CONTRACTOR. GENERAL NOTES (FIRE PROTECTION L RRE SVSTEM SHALL BE SUPPLIED FROM STANDPIPE STUB PROVIDED IN GARAGE PROJECT. 2. STANDPIPEWILLBECONSIDEREDWETTVPE,SUPPLIEDFROMFIREPUMP. 3. STANDPIPE SVSTEM SHALL BE INTERCONNECTEDAND PROVIDED WITH FlRE OEPARTMENT CONNECTION. 4. FLOW AND TAMPER SWITCHES SHALL BE PROVIDED AND INSTALLED BV THE SPRINKLER CONTRACTOR. WIRING CONNECTIONSAND EXTENSION TO MONITORING LOCATIONS SHALL BE PROVIDEO BV THE ELECTRICAL CONTRACTOR. 5. FIRE SUPPRESSION CONTRACTOR SHALL FURNISH AND INSTALL SPRINKLER SVSTEMS PER NFPA 13 GUIOELINES W ITHIN RETAIL AREAS AND NFPA 13R GUIDLINES IN RESIDENTIAL AREAS, STATE CODES AND LOCAL APPLICABLE CODES AND AMENDMENTS. 6. CONTRACTOR SHALL SECURE AND PAV FOR ALL FEES AND PERMITS ASSOCIATED W ITH THEIR PORTION OF THE WORK. ]. CONTRACTORSHALLCOORDINATEALLASPECTSOFTHEIRWORKWITHOTHERTRADES PRIOR TO INSTALLATION / CONSTRUCTION. 8. WORKUNDERTHEBUILDING#iPROJECTSHALLCONSISTOF,BUTNOTLIMITEDTO, FIIRNISHING, INSTALLATION, TESTING, AND WARRANTV OF FIRE Sl1PPRESSION PIPING INDICATED ON Pi SERIES DRAWINGS. 9. WHEN A CONFLICT BETNEEN PLANS AND SPEQRCATIONS OR NOTES OCCURS, THE RELEASEOFORCONSTRUCTION OVSHO SHALLGOVERNAIFLANVDISCREPANCIESAREE,MORE S Oft BETW EEN THE PLANS AND THE SPEQFlCATIONS, THE Suhjec��ocompliancewithallregula�ions `�THEGENERALCONTRACTORANDOBTAINCLARIFICATION 04 S�a�e antl Local Codes `-NGINEER PRIOR TO CONSTRUCTION OR INSTALLATION OF s. City of Carmel r � �\ �un��\i ��.r�fJi�tM�`�_ � oarE: 03/19 20 � FIXTURE SCHEDULE MARK DESCRIPTION MANUFACTURER MOOEL WASTE VENT HW CW SUPPLVITRIM SUPPLY/STOP WASTEfTRIM TR4P/FIX. �RAIN ADD FEATURES NOTES CLEVELAND FAUCET GROUP MULTI 2" P-TRAP, 42X60 ACRVLIC OROPW TUB WITH APRON. BTi BATHTUB STERLING 5711111120 P' 1 VT' ll2" 1/P' CFG46301CBNGR INTEGRAL W/ HOUSING DRAIN BRUSHED NICKEL FlNISH ON TRIM. CONTRACTORTO CFG45311 TUBISHOWERVALVE DIRECT522334 ANDOVERROW PROVI�ELEFTORRIGHTDRAINSPERPLANS. SVMMONS MULTI 2" P-TRAP, TO BE DETERMMED. PRESSURE BALANCE TUBI BT2 BATHTUB,ACCESSIBLE STERLING 5711111120 2" ���2" �2" ��z" 5-9603-X-PLR-05 INTEGRALW/ HOUSING DRAIN SHOWERVALVEWITHSTOPS.HANDHELDSHOWER 2 TUBISHOWERVALVE DIRECT522334 ANDOVERROW WITH60"HOSEANDMINIMUM30"SLIDEeAR. STOPS AT FAUCET, DWi DOGWASHSTATION OWNER OWNER p^ ���p•• ��p�� ��p�. T&SBrass CHECKVALVESON UNIT p••p_TRAP ACCESSORIESTOBEDETERMINED. T6066�RGH WATERSl1PPLIES CULTUREDMARBLETOP-WHITE POP-UPDRAIN WHITEUNDERMOUNTBOWLFORCULTUREDMARBLE LVi LAVATORV MULTIHOUSINGOIRECT SINGLE3�"x22"-CONTEMPOBS ���p•• ���y• ��p� ��p• CLEVELANDFAUCETGROUP ANGLESUPPLIESW/ INCL 1-0/q"p-TR4P VANITV.BRUSHEDNICKELFAUCETWITHCER4MIC DOUBLEfii'k22"-CONTEMPOBS CFG46100BN STOPS WITHFAUCET DISCANDSINGLELEVERHANDLE. CULTUREDMARBLETOP-WHRE POP-UPORAIN WHITEUNDERMOl1NT80WLFORCULTUREDMARBLE LV2 LAVATORY,ACCESSBLE MULTIHOUSINGOIRECT SINGLE3]'k22'-CONTEMPOBS 11/2" 11/4" ��p^ ��p• CLEVELANDFAUCETGROUP ANGLESUPPLIESW/ INCL 1-0/q"p-TR4P VANITV.BRUSHEDNICKELFAUCETWITHCERAMIC DOUBLE61'k22"-CONTEMPOBS CFG46700BN STOPS WITHFAUCET DISCANDADAAPPROVEDSWGLELEVERHANDLE. MAXIMUM ]" DEEP BOW L. STOPS AT FAUCET, MBi MOPBASIN PROFLO PFMB2424 3" 1112" 7/p" ��p^ TBSerass CHECKVALVESON UNIT 3"P-TRAP ACCESSORIESTOBEDETERMINED. TBO66�RGH WATERSUPPLIES 9" DEEP, 18 GAIIGE UNDERMOUNT STAMLESS STEEL ANGLE SUPPLIES WI STOPS TO SINGLE BOWL. BRUSHED NICKEL FlNISH ON TRIM, DOUBLE-COMPARTMENTSINKWITH CLEVELANDFAUCETGROUP SINK.AD�ITIONALSUPPLIES DISPOSER CERAMICDISCFAUCETWITHSPRAVER,DISPOSALIN- SKi DISPOSER PROFLO PFUC208 2" � ��z" ��2" ��2" CFGCA42519CSL �-��z P-TRP'P � WITHSTOPSTODISPOSERAND STRAINER SINK-ERATORBADGERiWITHWHIPFORELECTRICAL DISHWASHER CONNECTION. DISHWASHERSUPPLV&DRAIN CONNECTIONS. 18 GAUGE UNDERMOUNT STAINLESS STEEL SINGLE �OUBLE-COMPARTMENTSINKWITH CLEVELANDFAUCETGROUP ANGLESUPPLIESWISTOPS BOWLWITHOFFSETDRAINOUTLET.BRUSHEONICKEL SK2 DISPOSER, ACCESSIBLE ELKAV EWHAD311845 Z" � ��Z" ��Z�� ��z�� CFGCA42519CSL TO SWK. ADDITIONAL �ISPOSER 1z P T�P FINISH ON TRIM, CERAMIC DISC FAUCET WITH SUPPLIESWITHSTOPSTO STRAMER SPRAVER,DISPOSALIN-SINK-ERATORBADGERiWITH � DISPOSERAND DISHWASHER WHIP FOR ELECTRICAL CONNECTION. OISHWASHER SUPPLV & DRAIN CONNECTIONS. WCi TANKTVPE,FLOORSETWATERCLOSET PROFLO PF5112WHM 3" 11/2" - il2" UNIT ANGLESUPPLYW/STOP UNIT INTEGRAL PROFLO#PFTSE2000WHELONGATEDSEATINWHITE. PF1401TWH WCz TANKTVPE,FLOORSETWATER pROFLO PF5112WHM 3" 11/2" - il2" UNIT ANGLESUPPLYW/STOP UNIT INTEGRAL PROFLO#PFTSCOF2000WHELONGATEDSEATINWHITE. CLOSET. ADA/17" RIM PF1403TWH SCHEDULENOTES: 1. DISPOSER AS SELECTED BV OWNER. PROVIDE AIR SWITCH ON COl1NTER TO CONTROL OPERATION OF DISPOSER. 2 REFER TO ARCHITECTURAL DRAWINGS FOR MOUNTING LOCATIONS OFALL COMPONENTS. � VI 3/4 z BV GV �,�N 3/4" BV 13 3l4" 3/4"� �3/4" � il � �DV �N�� � TYPICAL UNIT MECHANICAL CLOSET - ISO VV BALLVALVE BV � DRAIN VALVE W ITH HOSE THREAD DV �� CHECK VALVE CHK "/� TEMPERATUREANDPRESSURERELIEFVALVE TP 1 � UNION CONNECTION WM WATER METER DIRECTION OF ROW NTEMPERWGVALVE - �W - WLD WATER - HW - HOT WATER � GAS VALVE GV - NG - GAS PIPING (NAT.) � DETAIL KEY NOTES: (TYPICAL UNIT MECH. CLOSET) f� 2. 3. 4. s. 6. �. 8. 9. 10. �i 12. 13. ia 15. 16. 1]. 18. 19. 20. 21. EXH/ PI i �aa:aHavaeu�i TYPICAL UNIT MECHANICAL CLOSET - PLAN 1 1/2" = 1� �" ET-1 EXPANSION TANK RISER G ALL '> v PLUMBING LEGEND SYMBOL DESCRIPTION VENT PIPING SANITARY PIPING - DOMESTIC COLD WATER PIPING - - DOMESTIC HOT WATER PIPING -OD- pVERFLOW DRAIN PIPING -ST- STORM DRAIN PIPING � BALLVALVE NG NATURALGAS � PIPE UP � PIPEDOWN #O KEVNOTE DESIGNATION OISOMETRIC DESIGNATION OUPTOABOVE 1 P-001 DETAIL DESIGNATION CO CLEANOUT DS STORMDOWNSPOUT FCO FLOORCLEANOUT FD ROOR DRAIN GCO GRADECLEANOUT LV LAVATORV OD OVERFLOW DRAIN ODS OVERFLOW DOWNSPOUT SAN SANITARY SK SINK SPD SUMP PUMP DISCHARGE SS SANITARV STACK ST STORM VR VENTRISER VS VENTSTACK VTR VENTTHRUROOF WC WATERCLOSET WCO WALLCLEANOUT WH WATERHEATER WHV� WALLHVDRANT FIRE PROTECTION LEGEND SYMBOL DESCRIPTION -F- FlRE PROTECTION PIPING -S- SPRINKLER PIPING N CHECKVALVE AL ALARM BELL FS FLOW SWITCH TS TAMPERSWITCH F�VC FIRE DEPARTMENT VALVE CABINET FDC FIREDEPARTMENTCONNECTION SP STANDPIPE FDV FIREDEPARTMENTVALVE ORD HAZARD DESIGNATION GPi PROVIDE CONNECTION TO TANKLESS WATER HEATER. HEATER PROVIDED BY MECHANICAL CONTRACTOR. PROVIDE HOT 8 COLD WATER MAMFOLD WITH INDIVIDUAL ISOLATION VALVES. ZURN QPPM (QUICK PORT) SERIES. DETERMINE MANIFOLD OUTLETS REOUIRED PER EACH UNIT. PROVIDE STUB FOR CONNECTION BY MECHANICAL CONTRACTOR. PIPWG TO AND FROM HVDRONIC AIR HANDLER PROVIDED BV MECHANICAL CONTRACTOR. GAS SUPPLV FROM GAS METER. GAS SUPPLY TO GAS RANGE PROVIDE GAS VALVE AND UNION AT CONNECTION. PIPMG TO BE RUN BELOW FLOORAN� RISE IN ISLAN� WALL. 1/2" PEX SUPPLV PIPING TO EACH INDIVIDUAL FlXTURE. CPVC WATER RISER, SEE PLANS FOR SIZES. TVPE "C' COPPER PIPING FROM CONNECTION TO WATER RISER TO ALL COMPONENTS W ITHIN CLOSET. PROVIDE THERMOSTATIC MIXING VALVE PER ASSE 10fi9 GUI�ELWES. POWERS/WATTS 3/4"-#LRM496-0. COORDINATE EXACT MOUNTING LOCATION WITH TANKLESS WATER HEATER. EXTEND T8P DISCHARGE TO FLOOR DRAIN FOR INDIRECT DISCHARGE. PROVIDE DIRT LEG AT BASE. TANKLESS WATER HEATER PROVIDED BV MECHANICAL CONTRACTOR. REFER TO DRAW WG M&501 FOR ELEVATION OF CLOSET. HVDRONIC AIR HANDLER PROVIDED BV MECHANICAL CONTRACTOR. REFER TO DRAW WG M2-501 FOR ELEVATION OF CLOSET. COIL ASSEMBLV PROVIDED BV MECHANICAL CONTRACTOR. REFER TO DRAW ING M2-501 FOR ELEVATION OF CLOSET. REFRIGERANT PIPING PROVIDED BV MECHANICALCONTRACTOR. EXHAlIST PIPING PROVIDEO BV MECHANICAL CONTRACTOR. INDICATES A�DITIONAL GAS SUPPLIES SERV W G ADDITIONAL ROORS. PEX MANIFOLD. GAS SUPPLV TO RANGE. ��� -�� WOOLPERT axwirec.une�eNmxeexix��ceosrnru� 76351nterective Way Suite 100 � Indianapolis, IN 46278 317.299.7500 FAX: 377.291.5805 novo�:: �r< . �r"o ,•G„�. IVo. Pc11tlOG2[% ;� - P �Ii�Tc(i' . n. �y E l�; �i �:7 � W � O W �` W � � J � J •� �Uw � Y I Q O 0 � � � i � � � L � U� u K m m � N ❑ N M �� � m a � U � � `o m �a � O � - �d �� � E N m - U 0 Issuances: Proi. No.: 074904 Date: 10/24/18 A Sheet Name: LEGEND, DETAILS, ANDSCHEDULES P 1-001 PLUMBING SHEET LIST Sheet Number Shee[ Name