Loading...
HomeMy WebLinkAboutA000.31900 Golf Road - Suite 300Schaumburg, Illinois 60173Midwest Zone OfficePLAN NAME SHEET PRODUCTION MANAGER DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN ID GARAGE HANDING REV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS INITIAL RELEASE DATE:CURRENT RELEASE DATE: (c) Copyright Pulte Home Corporation - 2020 Zach Bittner08/04/2014 Left Rockwall 2054.300.00.CPM LOT 44 11/12/2020 PLOTTED: November 12, 2020 / Prem Kumar / 2054-ROCKWALL-IN-WDSH-EL-HR3W-02.DWG A3-HR3W-02 3SB.1Heartland 3W-023 Car Side EntryFront, Side and Rear Elevations,Roof Plan & Attic Ventilation ScheduleSCALE:PORCH SECTIONS & DETAILS1/4" = 1'-0" SCALE:ELEVATION 21/4" = 1'-0"-SCALE:ELEVATION 11/4" = 1'-0"- \A1;8'-2{\H0.750000x;\S7#8;}" \A1;8" SCALE:FRONT ELEVATION1/4" = 1'-0"- 1210 1210 ROOF SHINGLES, PER SPEC 6" RAKE BOARD, PER SPECFRIEZE, PER SPEC 10" FRIEZE, PER SPEC BRICK ROWLOCK, \PPER SPECBRICK VENEER, \PPER SPEC 6" CORNER BOARD, PER SPEC HORIZONTAL SIDING, PER SPEC 8" TRIM, PER SPEC BRICK SOLDIER, PER SPEC 16" SHUTTER, \PPER SPEC 6" FASCIA BOARD, PER SPEC BRICK ROWLOCK, \PPER SPEC 16" SHUTTER, PER SPEC METAL ROOF, \PPER SPEC 4" TRIM, PER SPEC STONE VENEER, PER SPEC FYPON BRACKET #BKT14X16X4 OR APPROVED EQUAL STONE HEADER, PER SPEC FYPON #LV8X30 OR APPROVED EQUAL TOP OF FOUNDATION TOP OF FLOOR TOP OF PLATEWINDOW HEAD HGT. TOP OF PLATE TOP OF FLOOR WINDOW HEAD HGT. \A1;2'-2{\H0.750000x;\S7#8;}" \A1;8'-2{\H0.750000x;\S7#8;}" \A1;8" \A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}" \A1;8'-1{\H0.750000x;\S1#8;}"\A1;7'-2{\H0.750000x;\S7#8;}" SCALE:REAR ELEVATION1/8" = 1'-0" 12101210 1210 MASONRY WAINSCOT LINE OF FIREPLACE SCALE:LEFT ELEVATION1/8" = 1'-0" 128 124 \pxql;8" TRIM, PER SPEC. MASONRY WAINSCOT 128 \pxql;6" TRIM, PER SPEC. SCALE:RIGHT ELEVATION1/8" = 1'-0" 128 128 124 ROOF SHINGLES, PER SPEC BRICK VENEER, PER SPEC HORIZONTAL SIDING, PER SPEC TOP OF FOUNDATION TOP OF FLOOR TOP OF PLATEWINDOW HEAD HGT. TOP OF PLATE TOP OF FLOOR WINDOW HEAD HGT. LINE OF \PFIREPLACE \A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP. \A1;8'-1{\H0.750000x;\S1#8;}"\A1;7'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP. SCALE:ROOF PLAN1/8" = 1'-0"- MIN. 140 SQ. IN. OF VENTILATION REQUIRED AT EAVE FOR ROOF "D"ROOF AREASQ. FT."C"217 \A1;4'-0" 10:12 8:12 10:12 8:12 8:12 8:12 10:12 10:12 10:12 ROOF AREASQ. FT."A"2486PROVIDE ADEQUATE OPENING FOR AIR MOVEMENT BETWEEN ATTIC SPACES TO SUPPORT REQUIRED VENTILATION \A1;1'-0"\PTYP. 10:12 \A1;8'-0" \A1;6'-0" \A1;8'-0" \A1;10'-0"10:1210:12 4:12 10:12 10:1210:12 ROOF AREASQ. FT."B"5724:124:12 4:12 ELEVATION HR3W-IN1 ATTIC VENT SCHEDULE VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE ** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS * SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION ROOF AREA "C"SQ FTG 217 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 0.29 0.36 0.42 43.26 1 0 AT EAVE 0.43 0.36 0.56 56.74 0 8.00 TOTAL (MIN)0.72 0.72 0.98 100.00 3 HIGH - RIDGE VENT 0.29 0.36 0.50 47.37 0 0 4.00 AT EAVE 0.43 0.36 0.56 52.63 0 8.00 TOTAL (MIN)0.72 0.72 1.06 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE ELEVATION HR3W-IN1 ROOF AREA "A"SQ FTG 2486 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 3.31 4.14 3.39 43.65 8 0 AT EAVE 4.97 4.14 4.38 56.35 0 63.00 TOTAL (MIN)8.29 8.29 7.76 100.00 3 HIGH - RIDGE VENT 3.31 4.14 4.00 47.76 0 0 32.00 AT EAVE 4.97 4.14 4.38 52.24 0 63.00 TOTAL (MIN)8.29 8.29 8.38 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE ROOF AREA "C"SQ FTG 195 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 0.26 0.33 0.42 43.26 1 0 AT EAVE 0.39 0.33 0.56 56.74 0 8.00 TOTAL (MIN)0.65 0.65 0.98 100.00 3 HIGH - RIDGE VENT 0.26 0.33 0.50 47.37 0 0 4.00 AT EAVE 0.39 0.33 0.56 52.63 0 8.00 TOTAL (MIN)0.65 0.65 1.06 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE 01/05/21