HomeMy WebLinkAboutE200.01900 Golf Road - Suite 300Schaumburg, Illinois 60173Midwest Zone OfficePLAN NAME
SHEET
PRODUCTION MANAGER
DATE / DESCRIPTION
NPC PLAN NUMBERLAWSON PLAN ID
GARAGE HANDING
REV #
NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS
INITIAL RELEASE DATE:CURRENT RELEASE DATE:
(c) Copyright Pulte Home Corporation - 2020
Zach Bittner08/04/2014
Left
Rockwall
2054.300.00.CPM
LOT 44
11/12/2020
PLOTTED: November 12, 2020 / Prem Kumar / 2054-ROCKWALL-CZ-BASE-UTIL.DWG
U1
4-2.10Second Floor Utility Plan4" Exterior WallsTO SWITCH BELOW
FAN-EXHAUST-LIGHT
TO SWITCH BELOW
TO SWITCH BELOWFAN-EXHAUST
K-1125ARCHERBATHINGACRYLIC
SECOND FLOOR UTILITY PLAN
BEDROOM 4
BEDROOM 2
OWNER'S
SUITE
WIC
OWNER'S
RETREAT
BEDROOM 3
WIC
LAUNDRY
WIC
WIC
S
220VGAS VALVE
SSS
S
S
S
GFISSS
3S
S
3S
3S
SS
S
S
GFISSGFI
SS
S/C
S/C
S/C
PC 3S
S4
OPEN TO
BELOW
GFI
SSS
BATH 3
GFI
SS
OWNER'S
BATH
S
FAN-EXHAUST
VV
FAN-EXHAUST-LIGHT
BATH 2
SSV
3S 3S
\pxi-2,l2,ql,t3;{\T0.9;1. ALL ELECTRICAL INSTALLATION SHALL MEET THE REQUIREMENTS OF THE CURRENTLY ADOPTED EDITION OF THE NATIONAL ELECTRIC CODE (NEC). AND INTERNATIONAL RESIDENTIAL CODE (IRC). ALL MATERIAL AND EQUIPMENT SHALL BEAR THE LABEL OF APPROVAL OF THE UNDERWRITERS LABORATORIES, INC. AND MEET THE REQUIREMENTS OF THE CURRENTLY ADOPTED EDITION OF THE NEC.\P2. STAIRWAYS WITHIN DWELLING UNITS SHALL HAVE AN ILLUMINATION LEVEL ON THE TREAD RUNS OF NOT LESS THAN 1 FOOTCANDLE. PROVIDE LIGHTING CONTROL AT EACH LEVEL. EXTERIOR STAIRWAYS SERVING A DWELLING UNIT SHALL HAVE A LIGHT IN THE IMMEDIATE VICINITY OF THE STAIR LANDING CLOSEST TO THE DWELLING UNIT.\P3. GFCI PROTECTION SHALL BE PROVIDED FOR ALL 125 VOLT, SINGLE PHASE, 15 AND 20 AMPERE RECEPTACLES INSTALLED IN THE FOLLOWING LOCATIONS:\P\pi-3,l5,q*,t6;3.1. BATHROOMS\P3.2. GARAGE\P3.3. OUTDOORS: BALCONIES, DECKS, AND PORCHES (INCLUDING INSIDE SCREENED ENCLOSURES)\P3.4. UNFINISHED BASEMENT AREAS AND CRAWL SPACES\P3.5. SINKS LOCATEDUTILITY NOTESUTILITY LEGEND
SYMBOL SYMBOL TYPE ADDITIONAL NOITESADDRESS SIGNADDRESS SIGN - VISIBLE FROM STREET. LETTERS OR NUMBERS FOR THE ADDRESS SHALL BE 4" MIN. IN HEIGHT AND 0.5" MIN. IN STROKE OF A CONTRASTING COLOR TO THE BACKGROUND ITSELF
CHIMES - DOORBELLDETECTOR - HEATCEILING MOUNTED HEAT DETECTOR TO BE HARD WIRED TO FIRE ALARM SYSTEM (INSTALL PER CODE) DETECTOR - SMOKE/CARBON MONOXIDE COMBINATIONUL APPROVED CEILING MOUNTED SMOKE /CO DETECTOR TO BE HARD WIRED WITH BATTERY BACK-UP (INSTALL PER CODE)
DETECTOR - CARBON MONOXIDEUL APPROVED CEILING MOUNTED CO DETECTOR TO BE HARD WIRED WITH BATTERY BACK-UP (INSTALL PER CODE)
DETECTOR - SMOKEUL APPROVED CEILING MOUNTED SMOKE DETECTOR TO BE HARD WIRED WITH BATTERY BACK-UP (INSTALL PER CODE)DISCONNECT - SWITCHEDFAN - CEILING W/ LIGHTFAN BOX PER CODE. PROVIDE 4-WIRE CABLE FROM SWITCH(ES) (CLG FAN OPTIONAL)FAN - EXHAUSTEXHAUST TO EXTERIORFAN - EXHAUST W/ LIGHTEXHAUST TO EXTERIORLIGHT - CEILINGLIGHT - CEILING-PULL CHAINLIGHT - FLUORESCENT-48X9LIGHT - FLUORESCENT-UNDER CAB-14LIGHT - RECESSEDLIGHT - RECESSED-VAPOR PROOFLIGHT - WALLLIGHT - WALL-PULL CHAINMETER - ELECTRICVERIFY LOCATION IN FIELDOUTLET - 220VOUTLET - DISHWASHEROUTLET - DUPLEXOUTLET - DUPLEX-SPLIT WIREDOUTLET - FLOOROUTLET - GFIOUTLET - GARAGE DOOROUTLET - PHONECAT 5EOUTLET - TVRG-6OUTLET - WATERPROOF-GFIPANEL - ELECTRICVERIFY LOCATION IN FIELDSWITCH - DISPOSALSWITCH - LIGHTSWITCH - THREE WAYSWITCH - FOUR WAYSWITCH - PUSH BUTTONTHERMOSTATTHERMOSTAT SHALL BE PROGRAMMABLEHOSE BIBBWATER SERVICEGAS VALVEGAS METERRETURN AIR GRILLEWATER METER
HS/CCS
PC
14RVPCE220VDW
GFIGFIPHTVWP/GFISDISPS3SS4THBOPT.\PWATER LINEGAS VALVEGR.A.G.W
Smoke detector to be inside
tray ceiling, highest point
ensure smoke detector is at
least 36" from bath door
01/05/21