HomeMy WebLinkAboutFloor PlanDNDWUPUPARCHITECTURAL PLAN NOTES(ALL NOTES MAY NOT BE INDICATED ON THIS SHEET)INDICATES WALL TYPE. REFER TO DRAWING A1.00 FOR WALL THICKNESS,HEIGHT AND COMPOSITION.ARCHITECTURAL PLAN GENERAL NOTESA. ALL CMU WALLS THAT DO NOT LAY OUT IN FULL OR HALF LENGTHS SHOULD BE BALANCED SO AS NOT TO HAVE ANY PIECES LESS THAN 4" IN SIZE EXPOSED TO VIEW.B. WHERE DISSIMILAR FLOOR MATERIALS MEET, THEY SHALL DO SO UNDER THE CENTERLINE OF THE DOOR, UNLESS NOTED OTHERWISE. C. THERE SHALL BE PERIMETER INSULATION CONTINUOUS AROUND THE ENTIRE PERIMETER OF THE BUILDING EXTENDING 2'-0" MINIMUM BELOW GRADE. D. THE BASE FLOOR ELEVATION INDICATED FOR THE PROJECT IS 100'-0". REFER TO SITE PLAN FOR CORRELATION TO USGS DATUM. E. ALL INTERIOR MASONRY WALLS THAT RUN TO UNDERSIDE OF DECK ABOVE SHALL HAVE A 2" JOINT (U.N.O.) AT THE DECK TO BE FILLED WITH FIRE STOPPING AT RATED WALLS PER PROJECT MANUAL., AND MINERAL WOOL AT THE NON-RATED WALLS, TO ALLOW FOR DEFLECTION.F. FOR TYPICAL COMMON JOINT DETAILS AND CONSTRUCTION MOVEMENT JOINT DETAILS REFER TO DETAILS ON SHEET XX. G. ALL DIMENSIONS ON FLOOR PLANS ARE TO FINISH FACE OF CMU, CONCRETE, BRICK OR FINISH FACE OF GWB AT METAL STUD WALLS, UNLESS NOTED OTHERWISE. EXCEPTION: EXTERIOR METAL STUD WALLS ARE TO FACE OF METAL STUDS.H. HINGE SIDE DOOR JAMB AT WALLS WILL TYPICALLY BE LOCATED 4" MINIMUM FROM ADJACENT WALL UNLESS NOTED OTHERWISE. I. ALL EXPOSED CONCRETE MASONRY UNITS (CMU) CORNERS ARE TO BE BULLNOSE, EXCEPT AT WINDOW JAMBS, BULKHEADS, WINDOW AND DOOR HEADS. J. SEE REFLECTED CEILING PLANS FOR BULKHEAD LOCATIONS AND DETAIL REFERENCES. K. REFER TO ROOM FINISH SCHEDULE OR PLAN AND EQUIPMENT PLANS FOR LOCATION AND EXTENT OF FINISH FLOOR MATERIALS. L. PROVIDE WOOD BLOCKING AS REQUIRED. WITHIN METAL STUD WALLS FOR WALL MOUNTED ITEMS.M. REFER TO MASTER/CODE PLANS FOR CODE INFORMATION AND FIRE RATED WALL LOCATIONS. N. PROVIDE SPRAY FOAM INSULATION AND THERMAL BARRIER CONTINUOUS AT INTERSECTION OF EXTERIOR WALLS AND DECK.VERIFICATION NOTECONTRACTOR SHALL VERIFY ALL DIMENSIONS ANDCLEARANCES AND ALL EXISTING FIELD CONDITIONSBEFORE STARTING CONSTRUCTION. COMMENCEMENTOF WORK CONSTITUTES ACCEPTANCE OF CONDITIONS.SHOULD DIFFERENT CONDITIONS BE ENCOUNTERED,CONTACT THE ARCHITECT BEFORE PROCEEDING WITHWORK.XW###A3.01A3.01211A4.01P109P126P132P118P119P128P124P120P140P139P137P134S-1P132AP135P138P143P129UNIT P1UNIT P2P117P121P112P136S-2P142P1333A4.014A4.01P147P150P151P149S-3P141P153P156P155P152P123P122P144P125P127P130 P13156'-0"10'-8 1/2"11'-6 1/4"7 5/8"11'-2 1/2"11'-7"13'-7 3/4"34'-0"21'-1 3/4"52'-5 5/8"26'-2 5/8"83'-0 1/8"56'-10 3/8"41'-2"47'-7 3/8" ±13'-5"12'-2 5/8" ±13'-4"12'-7"12'-6 3/8" ±16'-0"28'-7"23'-3 3/8"40'-2 3/4"28'-0"11'-5"22'-11"83'-5 3/8"86'-2"1A5.051A5.042A5.043A5.042A5.053A5.051A5.062A5.063A5.061A5.07P113 P114P115P116P117AP145P148P146S-4P154P120AP121AP122AP123AP140AP133AP125AP127AP126AP130AP131AP129AP128AP139AP142AP144AP143AP146AP146BP146CP141AP141BP150AP149AP132A-AP140BP151AP151BP152AP152BP153AP154AP155AP147A7'-0"3'-0"6'-0"EQ EQ48'-0" ±2'-8"A3.022A3.024NEW FULL HEIGHT DISPLAY CASENEW FULL HEIGHT DISPLAY CASEPROVIDE CONCRETE FLOOR SLAB INFILL AT STAIR/LANDING DEMO. FINISH ELEVATION OF NEW SLAB TO ALIGN WITH EXISTING ADJACENT SLABW9W7W7W9W7W9W9W7W9W7W7W9W12W12W12W13W13W20W13W17W13W20W13W13W8W7W10W8W9W92A5.07W13W13W9W13W12W22W18W13W5W5W5W3W3W3W3W3W3W3W4W4W4W4W4W4W3W3W3W3W3W3W5W5W3W3W3W3W3W5W3W3W3AW3AW3AW3AW3W3W3W3W3W3W3P153BP156AP156B57'-8"238'-2 1/32"124'-10 21/32" 46'-1"NEW MASONRY SCREEN WALL DUMPSTER ENCLOSURE, REINSTALL EXISTING SCREEN DOORS22'-0"13'-4"4'-4"14'-0"1'-2"E1E2P1P2DCOPYRIGHT 2021 BY FANNING/HOWEY ASSOCIATES, INC.KEY PLANWWW.FHAI.COMARCHITECT1/11/2021 2:18:29 PM\\data1\citrixprofiles$\kshultz\My Documents\2019_ARCH_220114.00_kshultz.rvtPROJECT NUMBER: 220114.00CARMEL HIGHSCHOOLPERFORMINGARTS ADDITIONANDRENOVATIONSCARMEL CLAY SCHOOLS520 E MAIN STREETCARMEL, IN 46032UNIT P2 -FIRST FLOORARCHITECTURAL PLANA1.06PROJECT ISSUE DATE: 01/13/2021TAC SUBMITTALDRAWN BY: KT317-848-0966350 E NEW YORK ST# 300, INDIANAPOLIS, IN 46204NO.DESCRIPTIONSCALE: 1/8" = 1'-0"UNIT P2 - FIRST FLOOR - ARCHITECTURAL PLANNORTHROOM LEGEND - FIRST FLOOR UNIT P2ROOM NO. ROOM NAME AREA (SF)P136 PASSAGE121 SFP137 OFFICE134 SFP138 OFFICE97 SFP139 BAND STORAGE 937 SFP140 BAND7087 SFP141 ORCHESTRA3778 SFP142 ENSEMBLE119 SFP143 PRACTICE109 SFP144 PRACTICE116 SFP145 CORRIDOR370 SFP146 VESTIBULE96 SFP147 CORRIDOR1523 SFP148 ELEVATOR75 SFP149 ELEVATOR EQUIPMENT 86 SFP150 LARGE ENSEMBLE 870 SFP151 BAND INSTRUMENT STORAGE 1991 SFP152 SHARED REHEARSAL 3662 SFP153 KEYBOARDING 2111 SFP154 STORAGE87 SFP155 SPRINKLER RISER 110 SFP156 VESTIBULE67 SFS-1 STAIR117 SFS-2 STAIR144 SFS-3 STAIR97 SFS-4 STAIR215 SFROOM LEGEND - FIRST FLOOR UNIT P2ROOM NO. ROOM NAME AREA (SF)P112 LOBBY811 SFP113 RESTROOM149 SFP114 RESTROOM149 SFP115 UNIFORM DISTRIBUTION 529 SFP116 INSTRUMENT REPAIR 275 SFP117 CORRIDOR2027 SFP117A CUSTODIAL CLOSET 36 SFP118 PASSAGE280 SFP119 RECEPTION221 SFP120 RESTROOMS439 SFP121 RESTROOMS284 SFP122 RESTROOM62 SFP123 IDF85 SFP124 WORKROOM446 SFP125 PERCUSSION STORAGE 457 SFP126 ORCHESTRA INSTRUMENT STORAGE 1005 SFP127 OFFICE157 SFP128 PERCUSSION2502 SFP129 PERCUSSION OFFICE 167 SFP130 OFFICE159 SFP131 OFFICE165 SFP132 CORRIDOR651 SFP132A IDF33 SFP133 ELEC71 SFP134 OFFICE140 SFP135 OFFICE108 SFWILLIAME.PA YNEREGISTERED INDIANAAR CHITECT4169STATE OFNo.ACARMEL TAC REVIEW01/13/20213/32"REV.NO.DESCRIPTION DATE