Loading...
HomeMy WebLinkAboutA100.1NHB W02W02 W05W05 W03W03 D01D01 W03W03 W01W01 W04W04 D07D07 D05D05 D05D05 D03D03 A A501 A A501 B A501 B A501 A A502 A A502 C A505 C A505 B A502 B A50242'-0" OUTSIDE OF EXISTING STUD TO OUTSIDE OF NEW STUD7'-2" CL 13'-3 3/4" CL26'-0" 7'-6" CL 22'-5 1/2"19'-6 1/2" O/S EXISTING STUD TO O/S NEW STUD11'-2 3/4" CL2'-8" 7'-1 1/4" 7'-1 1/4"10'-8 1/2" 14'-4" 5'-1" 13'-5"6'-4" 4'-1" 4'-8 1/2" 5'-11 1/2"3'-7"16'-0"31'-0"8'-0"12'-0" 1'-0" 3'-0" 3'-0"8'-0"4'-4" CL4'-0" 16'-0" 5'-1" NEW FAMILY ROOM NEW MASTER BEDROOM DN NEW UTILITY ROOM NEW MASTER CLOSET NEW MASTER BATH PROPOSED CONSTRUCTION NOTES: - FURNISH & INSTALL NEW EXTERIOR WALLS WITH 2X6 BOTTOM PLATE, 2X6 STUDS @ 16" O/C, DOUBLE 2X6 TOP PLATES, 7/16" OSB EXTERIOR WALL SHEATHING, & TAPED HOUSEWRAP - FURNISH & INSTALL NEW INTERIOR WALLS WITH 2X4 BOTTOM PLATE, 2X4 STUDS @ 16" O/C, & DOUBLE 2X4 TOP PLATES - INSTALL HOMEOWNER-PROVIDED EXTERIOR DOOR AS SHOWN (REFER TO DOOR SCHEDULE FOR DETAILS) - INSTALL HOMEOWNER-PROVIDED WINDOWS AS SHOWN (REFER TO WINDOW SCHEDULE FOR DETAILS) - FURNISH & INSTALL R-19 KRAFT-FACED BATT INSULATION IN ALL NEW EXTERIOR WALLS & R-30 KRAFT-FACED INSULATION IN ALL NEW CEILING CAVITIES - FURNISH & INSTALL NEW DROP-DOWN ATTIC ACCESS IN NEW UTILITY ROOM - FURNISH & INSTALL NEW 1/2" DRYWALL ON ALL NEW WALLS, PAINTED - FURNISH & INSTALL NEW INTERIOR DOORS AS SHOWN (REFER TO DOOR SCHEDULE FOR DETAILS), PAINTED - FURNISH & INSTALL NEW JAMB MATERIAL & INTERIOR CASING TO MATCH EXISTING IN EXISTING ROUGH OPENING WHERE EXISTING EXTERIOR DOOR WAS REMOVED, PAINTED - FURNISH & INSTALL NEW DOOR & WINDOW CASING, BASE, & SHOE MOLDING IN ALL NEW ROOMS, PAINTED - FURNISH & INSTALL NEW PRE-FINISHED FIBER CEMENT EXTERIOR TRIM, SIDING, VENTED SOFFIT, & FASCIA ON NEW ADDITION - FURNISH & INSTALL NEW PRE-FINISHED FIBER CEMENT EXTERIOR TRIM, SIDING, VENTED SOFFIT, & FASCIA ON EXISTING FIRST FLOOR & SECOND FLOOR WOOD PANELED WALLS - FURNISH & INSTALL NEW CAST-IN-PLACE CONCRETE STOOP, STEP, & PATIO SLAB, SAND MATRIX FINISH (COLOR TBD) - HOMEOWNER TO PROVIDE & INSTALL NEW GAS-FIRED FORCED AIR FURNACE WITH A/C COMPRESSOR, ASSOCIATED SUPPLY & RETURN AIR DUCTWORK, & PROGRAMMABLE THERMOSTAT. NEW HVAC SYSTEM TO SERVE NEW ADDITION ONLY. - FURNISH & INSTALL NEW GAS LINE TO NEW FURNACE LOCATION - FURNISH & INSTALL NEW HOT WATER LINES, COLD WATER LINES, & PVC DRAIN LINES AS NECESSARY FOR NEW SINKS, TOILET, SHOWER, & HVAC CONDENSATE DRAIN AS REQUIRED. ** REFER TO ENLARGED PLANS FOR BATHROOM DETAILS** **ALL DIMENSIONS SHOWN ARE STUD TO STUD OR CENTERLINE OF ROUGH OPENING UNLESS NOTED OTHERWISE** TOP OF EXISTING SUBFLOOR = 0' 0" TOP OF NEW SUBFLOOR = 0' 0" TOP OF NEW SLAB = - 1' 3" A A601 A A601 A A601 A A601 A A602 A A602 A A602 A A602 NEW CONCRETE PATIO A A401 A A401 PERMIT #0 ISSUE DATE: 2020-12-22 REV: www.caseindy.com 99 E. Carmel Drive, Suite 100 Carmel, Indiana 46032 317.846.2600 317.846.2601(f) These drawings have been prepared by Case Design & Remodeling solely for its use and should not be reproduced or relied upon by any other parties. Dimensions shown or scaled are subject to change per actual job condition and must be verified. Materials are to be supplied as specified as equal or standardwhen not uniquely specified. Installed materials may vary in appearance from drawings. Reference manufacturer's product data for actual appearance and specifications.SCHIPP RESIDENCEMASTER SUITE / SUNROOMADDITIONDAVID & JULIE SCHIPP11111 HAVERSTICK ROADCARMEL, INDIANA 46033Approved By: Date: A101 Craig Dice Architectural Designer cdice@caseindy.com 252590170 JOB NUMBER: Dawn Ashburn Project Developler dashburn@caseindy.com FIRST FLOOR PROPOSED FLOOR PLANA A101 A A101 SCALE: 3/16" = 1'-0" #1 2021-01-08 01/25/21