HomeMy WebLinkAboutS001.0N41'-7 1/2" O/S EXIST. BRICK TO O/S NEW CMU26'-0"22'-5 1/2"19'-2" O/S EXIST. BRICK TO O/S NEW CMU 4'-0"8'-2"8'-2" 8'-2 3/4"8'-2 3/4" 8'-2" 13'-0" 13'-0"
FURNISH & INSTALL NEW 3-PLY 2X12 FLOOR GIRDER
ON NEW TREATED 2X12 SILL PLATE, CENTERED ON
PIER BELOW
FURNISH & INSTALL NEW 2X10 FLOOR JOISTS @ 16"
OC. FLOOR JOISTS TO BEAR ON TREATED 2X4 SILL
PLATES AT EXTERIOR FOUNDATION WALLS, TREATED
2X12 SILL PLATES AT PIERS, OR FROM FACE OF FLOOR
GIRDER WITH SIMPSON STRONG-TIE HU210 (OR
EQUIV.) JOIST HANGER
FURNISH & INSTALL NEW 3/4" T&G OSB SUBFLOOR,
GLUED & SCREWED TO NEW FLOOR JOISTS
FURNISH & INSTALL NEW 2X10 RIM JOISTS
LINE UP WITH OUTSIDE OF
NEW FOUNDATION WALL
WITH EXISTING NORTH
FOUNDATION WALL
FURNISH & INSTALL NEW PEA GRAVEL OVER 6 MIL
VISQUEEN IN NEW CRAWLSPACE
FURNISH & INSTALL NEW (2) 32"W X 16"H OPENINGS
THROUGH EXISTING CMU FOUNDATION WALL FOR
DUCTWORK, PIPING, & MAN ACCESS BETWEEN
EXISTING CRAWLSPACE AND NEW CRAWLSPACE
(FIELD VERIFY BEST LOCATION)
FURNISH & INSTALL NEW PERIMETER DRAIN TILE TO
TIE INTO EXISTING
FURNISH & INSTALL WATERPROOFING ON OUTSIDE
FACE OF NEW CMU FOUNDATION WALLS
FURNISH & INSTALL 2"T FOAM INSULATION ON INSIDE
FACE OF NEW CMU FOUNDATION WALLS
FURNISH & INSTALL NEW 8"CMU FOUNDATION WALL
ON 16"W X 8" CAST-IN-PLACE CONCRETE CONTINUOUS
FOOTINGS
FURNISH & INSTALL (5) NEW 16" SQUARE CMU PIER ON
32" SQUARE X 8"D CAST-IN-PLACE CONCRETE
FOOTING
FURNISH & INSTALL NEW 2X8 FLOOR JOISTS @ 16" O/C.
BOTTOM OF 2X8 JOIST TO BE FLUSH WITH BOTTOM OF
2X10 JOIST FOR RECESSED FLOOR AT SHOWER AREA
FURNISH & INSTALL NEW 32"W X 16"H OPENING
THROUGH NEW CMU FOUNDATION WALL FOR CRAWL
SPACE ACCESS (FIELD VERIFY BEST LOCATION
PRIOR TO FOUNDATION WALL INSTALLATION)
PERMIT
#0
ISSUE DATE:
2020-12-22
REV:
www.caseindy.com
99 E. Carmel Drive, Suite 100
Carmel, Indiana 46032
317.846.2600 317.846.2601(f)
These drawings have been prepared
by Case Design & Remodeling solely
for its use and should not be
reproduced or relied upon by any
other parties. Dimensions shown or
scaled are subject to change per
actual job condition and must be
verified. Materials are to be supplied
as specified as equal or standardwhen not uniquely specified. Installed
materials may vary in appearance
from drawings. Reference
manufacturer's product data for actual
appearance and specifications.SCHIPP RESIDENCEMASTER SUITE / SUNROOMADDITIONDAVID & JULIE SCHIPP11111 HAVERSTICK ROADCARMEL, INDIANA 46033Approved By:
Date:
S101
Craig Dice
Architectural Designer
cdice@caseindy.com
252590170
JOB NUMBER:
Dawn Ashburn
Project Developler
dashburn@caseindy.com
FOUNDATION & FLOOR FRAMING PLANA
S101
A
S101 SCALE: 3/16" = 1'-0"
#1 2021-01-08
01/25/21