Loading...
HomeMy WebLinkAboutS001.0N41'-7 1/2" O/S EXIST. BRICK TO O/S NEW CMU26'-0"22'-5 1/2"19'-2" O/S EXIST. BRICK TO O/S NEW CMU 4'-0"8'-2"8'-2" 8'-2 3/4"8'-2 3/4" 8'-2" 13'-0" 13'-0" FURNISH & INSTALL NEW 3-PLY 2X12 FLOOR GIRDER ON NEW TREATED 2X12 SILL PLATE, CENTERED ON PIER BELOW FURNISH & INSTALL NEW 2X10 FLOOR JOISTS @ 16" OC. FLOOR JOISTS TO BEAR ON TREATED 2X4 SILL PLATES AT EXTERIOR FOUNDATION WALLS, TREATED 2X12 SILL PLATES AT PIERS, OR FROM FACE OF FLOOR GIRDER WITH SIMPSON STRONG-TIE HU210 (OR EQUIV.) JOIST HANGER FURNISH & INSTALL NEW 3/4" T&G OSB SUBFLOOR, GLUED & SCREWED TO NEW FLOOR JOISTS FURNISH & INSTALL NEW 2X10 RIM JOISTS LINE UP WITH OUTSIDE OF NEW FOUNDATION WALL WITH EXISTING NORTH FOUNDATION WALL FURNISH & INSTALL NEW PEA GRAVEL OVER 6 MIL VISQUEEN IN NEW CRAWLSPACE FURNISH & INSTALL NEW (2) 32"W X 16"H OPENINGS THROUGH EXISTING CMU FOUNDATION WALL FOR DUCTWORK, PIPING, & MAN ACCESS BETWEEN EXISTING CRAWLSPACE AND NEW CRAWLSPACE (FIELD VERIFY BEST LOCATION) FURNISH & INSTALL NEW PERIMETER DRAIN TILE TO TIE INTO EXISTING FURNISH & INSTALL WATERPROOFING ON OUTSIDE FACE OF NEW CMU FOUNDATION WALLS FURNISH & INSTALL 2"T FOAM INSULATION ON INSIDE FACE OF NEW CMU FOUNDATION WALLS FURNISH & INSTALL NEW 8"CMU FOUNDATION WALL ON 16"W X 8" CAST-IN-PLACE CONCRETE CONTINUOUS FOOTINGS FURNISH & INSTALL (5) NEW 16" SQUARE CMU PIER ON 32" SQUARE X 8"D CAST-IN-PLACE CONCRETE FOOTING FURNISH & INSTALL NEW 2X8 FLOOR JOISTS @ 16" O/C. BOTTOM OF 2X8 JOIST TO BE FLUSH WITH BOTTOM OF 2X10 JOIST FOR RECESSED FLOOR AT SHOWER AREA FURNISH & INSTALL NEW 32"W X 16"H OPENING THROUGH NEW CMU FOUNDATION WALL FOR CRAWL SPACE ACCESS (FIELD VERIFY BEST LOCATION PRIOR TO FOUNDATION WALL INSTALLATION) PERMIT #0 ISSUE DATE: 2020-12-22 REV: www.caseindy.com 99 E. Carmel Drive, Suite 100 Carmel, Indiana 46032 317.846.2600 317.846.2601(f) These drawings have been prepared by Case Design & Remodeling solely for its use and should not be reproduced or relied upon by any other parties. Dimensions shown or scaled are subject to change per actual job condition and must be verified. Materials are to be supplied as specified as equal or standardwhen not uniquely specified. Installed materials may vary in appearance from drawings. Reference manufacturer's product data for actual appearance and specifications.SCHIPP RESIDENCEMASTER SUITE / SUNROOMADDITIONDAVID & JULIE SCHIPP11111 HAVERSTICK ROADCARMEL, INDIANA 46033Approved By: Date: S101 Craig Dice Architectural Designer cdice@caseindy.com 252590170 JOB NUMBER: Dawn Ashburn Project Developler dashburn@caseindy.com FOUNDATION & FLOOR FRAMING PLANA S101 A S101 SCALE: 3/16" = 1'-0" #1 2021-01-08 01/25/21