HomeMy WebLinkAboutM101.0N
R RR
R RR
GFI
GFI
RA
GD
R
R
R
GD
H
A
M
6/26/2
6/16/1
6/46/4
6/46/4
6/56/5
E6E6
DINING ROOM
C.H. 108" AFF
HARDWOOD
LAUNDRY
C.H. 108" AFF
TILE
KITCHEN
C.H. 108" AFF
TILE
FAMILY ROOM
C.H. 108" AFF
HARDWOOD
P3P3
E3E3 H1H1
D D
P1P1
P2P2
E7E7
E8E8
E6E6
E5E5 E4E4
E5E5
E5E5
E9E9
E13E13
E5E5
E10E10
E11E11
E12E12
PROPOSED ELECTRICAL PLAN NOTES
NOTE QTY DESCRIPTION
1
ELECTRICIANS TO VERIFY CURRENT SMOKE AND CO
DETECTORS IN HOME ARE BROUGHT UP TO MEET
CURRENT CODE REQUIREMENTS
1 ELECTRICIANS TO VERIFY OUTLETS AND SWITCHES MEET
CURRENT GFCI PROTECTION CODE REQUIREMENTS
1 NEW CAN LIGHT TO MATCH EXISTING. INSTALL ON SAME
CIRCUIT.
1 PROVIDE OUTLET FOR ABOVE COUNTER WALL MICROWAVE
4 RELOCATE EXISTING OUTET, REFERENECE ELEVATIONS
FOR LOCATIONS
1 EXISTING HOOD AND RANGE OUTLETS
1 NEW PENDANT LIGHTS ON DIMMER SWITCH
1 DIMMER SWITCHES
1 LOWER OUTLET IN WALL TO ALIGHN WITH ADJ. EXISTING
OUTLET
1 RUN NEW DEDICATED OUTLET FOR RELOCATED
REFRIGERATOR
1 DEAD SWITCH AFTER SEMI FLUSH FIXTURE IS REMOVED
FROM KITCHEN CEILING
1 RELOCATED OUTET
1 RELOCATE EXISTING OUTET FROM FACE OF PANEL
E1E1
E2E2
E3E3
E4E4
E5E5
E6E6
E7E7
E8E8
E9E9
E10E10
E11E11
E12E12
E13E13
E1E1
E2E2
E3E3
E4E4
E5E5
E6E6
E7E7
E8E8
E9E9
E10E10
E11E11
E12E12
E13E13
PROPOSED PLUMBING PLAN NOTES
NOTE QTY DESCRIPTION
1 REPLACE ALL VALVES AND RE-INSTALL EXISTING
DISHWASHER
1
RELOCATE WATER LINE AND DRAIN FOR ICEMAKER/WATER
DISPENSER AND PROVIDE NEW SHUT-OFF VALVES.
APPLIANCE INSTALLERS TO PROVIDE FINAL CONNECTION
1 HOOK-UP NEW SINK DRAIN, INSTALL AND HOOK-UP NEW
FAUCET, AND GARBAGE DISPOSAL AIR SWITCH.
P1P1
P2P2
P3P3
P1P1
P2P2
P3P3
PROPOSED HVAC PLAN NOTES
NOTE QTY DESCRIPTION
1 INSTALL NEW EXHAUST HOOD AND DIRECT VENT
DUCTWORKH1H1H1H1
REFRIGERATOR OUTLET
MICROWAVE OUTLET
DISHWASHER POWER SUPPLY
HOOD VENT POWER SUPPLY
GARBAGE DISPOSAL POWER SUPPLY
COOKTOP POWER SUPPLY
CLOTHES DRYER OUTLET
CLOTHES WASHER OUTLET
110V OUTLET
220/240V OUTLET
GFCI OUTLET
OUTDOOR OUTLET
LOW VOLTAGE TRANSFORMER
SINGLE POLE SWITCH
DIMMER SWITCH
3-WAY SWITCH
4-WAY SWITCH
GD WALL SWITCH
GD COUNTERTOP AIR SWITCH
LOW VOLTAGE LIGHTING SWITCH
TIMER SWITCH
OCCUPANCY SWITCH
SURFACE MOUNT LIGHT FIXTURE
4" RECESSED CAN LIGHT
6" RECESSED CAN LIGHT
6" RECESSED CAN/FAN UNIT
EXHAUST FAN ONLY
EXHAUST FAN W/ LIGHT
WALL MOUNTED SCONCE / LIGHT
CEILING FAN
LOW VOLTAGE LIGHT
SMOKE DETECTOR
CARBON MONOXIDE DETECTOR
SMOKE/CARBON MONOXIDE
MOTION SENSOR
CEILING SPEAKER MASON & LO WEBBKitchen Remodel9611 Prairiewood WayIndianapolis, IN 46032Date:Revision:
4
SHEET OF 7
SIGNATURE / SEAL
Client Initials:
Date:
The plans, including all text, drawings, concepts, and ideas
forming a part of the plans and the selection and arrangement
thereof are Copyright 2018 of Custom Living, Inc., Indianapolis,
IN. ALL RIGHTS RESERVED. The plans shall remain the
property of Custom Living Inc. Any use of the plans or their
content without the prior written permission of Custom Living Inc.
is strictly prohibited. CUSTOM LIVING5335 Winthrop AveIndianapolis IN 462201/29/2021
DATE:
GENERAL M.E.P NOTES
HVAC Contractor is responsible for engineering
calculation necessary for correct sizing of new
equipment and ductwork being supplied,
fabricated and installed for the project.
HVAC ductwork being installed in unconditioned
areas to be insulated and sealed per current
Building Code Standards.
HVAC contractor to start, test, and balance any
new equipment and ductwork to assure proper
operation of new systems.
Final plumbing materials selected may have an
affect on the final Plumbing Material and
Installation Budgets.
Owners understand that if additional plumbing,
electrical or ductwork is found in walls being
deleted that is not included on the plans there
will be a Change Order during construction to
relocate as necessary.
Owners understand that during mechanical
rough-ins there will be times when the water
service will be shut off to areas in the home.
Plumbing and Lighting fixtures supplied by
Owner will not be warrantied by Custom Living
Plumbing and Lighting fixtures supplied by
Owner must be selected and on-site prior to start
of mechanical rough-ins.
[PRINTS TO SCALE IF PRINTED ON 24" X 36" ] DESIGNER: NIKKI SUTTONE: nikki@customlivingusa.comC: 317.370.0638PROPOSED M.E.P. PLAN
SCALE: 5/8" = 1'
ELECTRICAL KEY
02/02/21