HomeMy WebLinkAboutS101.0EXISTING 2X4 FRAMING
DEMOLITION & FRAMING KEY
NO DEMO IN THIS ROOM
EXISTING 2X6 FRAMING
WALL SECTION TO BE REMOVED
NEW 2x4 FRAMING
NEW 2X6 FRAMING
BULK HEAD / LOWERED CEILING
N21068EXISTING EXISTING
3068EXISTING
FLOOR
6/26/2
6/16/1
6/46/4
6/46/4
6/56/5
E6E6
7'11'-11 1/2" 8'-1"4' 8'-4 1/2"8'-10 1/4" 11'-4 3/4"3'-7 3/8"2'-1 1/2"89 5/8" 11'-6 1/4"2'-6"5'-1 1/4"DW 3" END PANEL36X27X21DINING ROOM
C.H. 108" AFF
HARDWOOD
LAUNDRY
C.H. 108" AFF
TILE
KITCHEN
C.H. 108" AFF
TILE
FAMILY ROOM
C.H. 108" AFF
HARDWOOD
PANTRY
F2F2 F1F1
F3F3
D3D3
D4D4
D2D2
D1D1
D1D1
D5D5
FRAMING PLAN NOTES
NOTE QTY DESCRIPTION
1 PROPOSED FRAMING PLAN NOTES
1 INSTALL WALL BLOCKING FOR NEW WALL SHELVES
1 INSTALL NEW DOOR, REUSE EXISTING HARDWARE
F1F1
F2F2
F3F3
F1F1
F2F2
F3F3
INSULATION PLAN NOTES
NOTE QTY DESCRIPTION
DRYWALL PLAN NOTES
NOTE QTY DESCRIPTION
2 PATCH DRYWALL AFTER ABOVE COUNTER OUTLETS ARE
SHIFTED ON NEW CENTER LINES
1
PATCH AND REPAIR CEILING AS NEEDED AFTER
DELETING PENDANT AND FLUSH MOUNT LIGHT
FIXTURES AND ADDING TWO NEW CAN LIGHTS
1 PATCH DRYWALL AFTER WALL BLOCKING FOR FLOATING
SHELVES IS INSTALLED BETWEEN WALL STUDS
1
PATCH AND REPAIR DRYWALL WHERE CROWN
MOULDING AND CHAIR RAIL WERE REMOVED, AS
NEEDED
1 REPAIR DRYWALL AFTER KNEE WALL IS LOWERED, PREP
FOR PAINTED SURFACE
D1D1
D2D2
D3D3
D4D4
D5D5
D1D1
D2D2
D3D3
D4D4
D5D5
1'-4" 7'-8 5/8"HEADER (WINDOWS & DOORS):
DOUBLE 2X8
DOUBLE TOP PLATE
KING STUD
CRIPPLE STUD
BOTTOM PLATE
O.C.
3/4" SUBFLOOR
2x8 CEILING JOISTS
2X10" LVL FLOOR JOISTS
@ 16" O.C.MASON & LO WEBBKitchen Remodel9611 Prairiewood WayIndianapolis, IN 46032Date:Revision:
3
SHEET OF 7
SIGNATURE / SEAL
Client Initials:
Date:
The plans, including all text, drawings, concepts, and ideas
forming a part of the plans and the selection and arrangement
thereof are Copyright 2018 of Custom Living, Inc., Indianapolis,
IN. ALL RIGHTS RESERVED. The plans shall remain the
property of Custom Living Inc. Any use of the plans or their
content without the prior written permission of Custom Living Inc.
is strictly prohibited. CUSTOM LIVING5335 Winthrop AveIndianapolis IN 462201/29/2021
DATE:
GENERAL PROPOSED PLAN NOTES
Framing contractors are responsible for all labor,
for the scope of work specified on the drawings
provided by Custom Living.
Owner understands that Custom Living has only
provided a labor and material allowance for the
scope of Rough Carpentry work specified on the
drawings. Any additional work added or
uncovered during this scope will be filed as a
Change Order during construction
Owner understands that the drywall allowance is
based on an estimated board count and square
footage take-off. A final walk through with a
drywall contractor after framing and mechanical
rough-ins will be necessary to finalize drywall
installation and finish budgets.
Final drywall touch-ups will follow countertop
installation.
[PRINTS TO SCALE IF PRINTED ON 24" X 36" ] DESIGNER: NIKKI SUTTONE: nikki@customlivingusa.comC: 317.370.0638PROPOSED FLOOR PLAN
SCALE: 5/8" = 1'
TYPICAL FRAMING DETAIL
SCALE: 3/8" = 1' 0"
02/02/21