U.S. Architectural Lig hting 660 West Avenue O, Palmdale, CA 93551
Phone (661) 233-2000 Fax (661) 233-2001
www.usaltg.com
PATENT PENDING
LPC
Light Pollution Co ntrol Cl assifi cati on Sy stem
Full cutoff 0% U p light Lumin aire
HOUSING
Heavy cast low copper aluminum assembly (A356 alloy,
<.2% copper) minimum wall thickness .188" with integral
cooling ribs surrounding the electrical compartment. The
optical and electrical compartments are integrated with
the support arm to create one assembly. Minimum wall
thickness is ¼". Cast and hinged driver compartment
cover is integrated with wiring compartment cover.
OPTICAL MODULE
Low copper A356 alloy (<.2% copper) cast aluminum housing.
Integrated clear tempered glass lens sealed with a
continuous silicone gasket protects emitters (LED's) and
emitter Reflector-Prism optics, and seals the module from
water intrusion and environmental contaminants. Each
emitter is optically controlled by a Reflector-Prism injection
molded from H12 acrylic (3 types per module; one from 0° -
50°; one from 50° - 65°; one from 65° - 72°). Each Reflector-Prism
has indexing pins for aiming and is secured to an optical
plate made of matte black anodized aluminum. The optical
plate locates every Reflector-Prism over an emitter.
Reflector-Prisms are secured to the optical plate with a UV
curing adhesive. The Reflector-Prisms are arrayed to produce
IES Type II, IES Type III and IES Type IV distributions. The entire
Optical Module is field rotatable in 90° increments. Both
module and drivers are factory wired using water resistant,
insulated cord. Lens, module and drivers are field replaceable.
LED DRIVER
UL and CUL recognized High Power Factor, Constant
Current LED drivers operate on input voltages from
120-277V, 50/60Hz or 347-480V, 50/60Hz. Driver is
mechanically fastened to a retaining bracket. Main
power quick disconnect provided. (0 - 10V dimmable
driver is standard. Driver has a minimum of 3KV
internal surge protection. Luminaire supplied with
20KV surge protector for field accessible installation.)
LED EMITTERS
High Output LED’s are available in standard Neutral
White (4000K), or optional Cool White (5000K) or Warm
White (3000K). Consult Factory for other LED options.
AMBER LED’s
PCA (Phosphor Converted Amber) LED’s utilize phosphors
to create color output similar to LPS lamps and have a
slight output in the blue spectral bandwidth. TRA (True
Amber) LED’s utilize material that emits light in the amber
spectral bandwidth only without the use of phosphors.
FINISH
Polyester powder coat incorporates four step iron
phosphate process to pretreat metal surface for
maximum adhesion. Top coat is baked at 400°F for
maximum hardness and exterior durability.
®
SOLID STATE LIGHTING
PROJECT NAME:
PROJECT TYPE:
TSU WALLMOUNT LED
SPECIFICATIONS
C US
LISTED
15"(381mm)
15"(381mm)
15.63"(387mm)
16.5"(419mm)
9"(229mm)
9"(229mm)
9.25"(235mm)
4.50"(114mm)
1.75"(44mm)
4.50"(114mm)
J-BOX J-BOX
TSUW*
UP LIGHTING CONFIGURATIONDOWN LIGHTING CONFIGURATION
*DOWNLIGHT CONFIGURATION SHOWN
DARK BRONZE
RAL-8019-T
GREEN
RAL-6005-T
WHITE
RAL-9003-T
GREY
RAL-7004-T
BLACK
RAL-9005-T
CHROME
LC
BLACK
LB
LATCH COLOR
FOR SMOOTH FINISH
REPLACE SUFFIX “T” WITH
SUFFIX “S”
(EXAMPLE: RAL-9005-S)
64LED
48LED
TSUW-LED
IES DISTRIBUTION TYPE
No. LEDs
TYPE I I
VLED - II . . . . . . . .
TYPE I I I
VLED - III . . . . . . . . . .
TYPE I V
VLED - IV . . . . . . . . . .
OTHER LED COLORS
AVAILABLE
CONSULT FACTORY
COLOR
NW (4000K)*
*STANDARD
CW (5000K)
WW (3000K)
VOLTAGE
120
208
240
277
347
480
®
64 LED Module
SPECIFICATIONS
TSUNAMI WALLMOUNT - LED
SPEC/ORDERING INFORMATION
TSUW-VLEDAvailable in:48 LED Module 64 LED Module
48 LED Module
WALL MOUNT
WALL PLATE
MODULE®
STANDARD
TEXTURED FINISH
Spec/Order Example: TSUW-LED/VLED-IV/64LEDNW208/RAL-6005-T/PC+V
PHOTO CELL + VOLTAGE(EXAMPLE: PC120V) . . . PC+V
TWIST LOCK PHOTOCELLRECEPTACLE ONLY . .TPR
HOUSE SIDE SHIELDED
REFLECTOR-PRISMS. . HS-VLED
HIGH-LOW DIMMING FOR
HARDWIRED SWITCHING OR
NON-INTEGRATED MOTION
SENSOR . . . . . . . . . . . .HLSW
SINGLE FUSE
(120V. , 277V) . . . . . .SF
DOUBLE FUSE
(208V. , 240V) . . . . . .DF
7-PIN TWIST LOCKRECEPTACLE ONLY . .TPR7
REMOTE MOTION SENSOR
CONFIGURATOR . . . .MS-FC10
STEP DIM MOTION SENSOR (PROGRAMMED 50/100)
. . . . . . . . . . . . . . . . . .MS-F211
MODEL OPTICS LED MODE FINISH OPTIONS
OPTICS LED MODE
VOLTAGE
VOLTAGE FINISH OPTIONSMODEL
U.S. Architectural Lig hting 660 West Avenue O, Palmdale, CA 93551
Phone (661) 233-2000 Fax (661) 233-2001
www.usaltg.com
11.25"
(286mm)
7.50"
(191mm)
.5" DIA. (13mm)
(4) HOLES
7.50"
(191mm)
5.50"
(140mm)
5.50"
(140mm)
5.50"
(140mm)
7.00"
(178mm)
7.00"
(178mm)
5.50"
(140mm)
.5" DIA. (13mm)
(4) HOLES
UP LIGHTING MOUNTING BRACKETDOWN LIGHTING MOUNTING BRACKET
GALVANIZED STEEL MOUNTING PLATE
FOR DOWN CONFIGURATION
PROVIDED WITH BUILT IN GASKETED
WIRE ACCESS FOR FIXTURE/SUPPLY
WIRE CONNECTION.
CAST ALUMINUM MOUNTING PLATE
FOR UP CONFIGURATION PROVIDED
WITH BUILT IN GASKETED WIRE
ACCESS FOR FIXTURE/SUPPLY WIRE
CONNECTION.
DRIVE CURRENT
AMBER2
PHOSPHOR
CONVERTED
AMBER
PCA
TRUE AMBER
TRA
NOTES:1 - NOT AVAILABLE IN 347-480V
2 - NARROW BAND AMBERS HAVE NO DEFINABLE CCT EQUIVALENT
525mA1
350mA
TSUNAMI WALLMOUNT - LED
660 West Avenue O, Palmdale, CA 93551
Phone (661) 233-2000 Fax (661) 233-2001
www.usaltg.com
U.S . A rch i t ect ural L i g htin g
INITIAL
LUMENS -
4000K
L70 GREATER
THAN (HR)
60,000+
STARTING
TEMP.
-20°F
VOLTS
120
277
347
SYSTEM
WATTS
55
MAX
INPUT AMPS
0.46
0.20
0.16
LED
COUNT
48
SOURCE
TYPE
LED
SOURCE
48 Optical
Module - 350mA
60,000+-20°F 120
277
347
79 0.66
0.29
0.23
48 LED 48 Optical
Module - 525mA
60,000+-20°F 120
277
347
70 0.59
0.26
0.21
64 LED 64 Optical
Module - 350mA
60,000+-20°F 120
277
347
108 0.90
0.39
0.32
64 LED 64 Optical
Module - 525mA
4,241 –
4,760
5,871 –
6,557
5,255 –
5,898
7,393 –
8,257
INITIAL
LUMENS -
3000K
3,731 –
4,187
5,152 –
5,755
4,623 –
5,189
6,488 –
7,246
INITIAL
LUMENS -
5000K
4,337 –
4,868
6,009 –
6,711
5,373 –
6,031
7,566 –
8,451
LED/ELECTRIC AL G UID E
®
®
®
®
NOTES:
1.
2.
3.
4.
5.
Max Input Amps is the highest of starting, operating, or open circuit currents
Lumen values for LED Modules vary according to the distribution type
System Watts includes the source watts and all driver components.
Fuse value should be sufficient to protect all wiring components. For electronic driver and LED
component protection, use 10KV – 20KV surge suppressors.
L70(9K) – TM-21 6x rule applied
WARNING: All fixtures must be installed in accordance with local codes or the National Electrical Code. Failure to do so may result in serious personal injury.