Loading...
HomeMy WebLinkAboutC401 Site Utility Plan///////////// ////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// ///////////////////// //////////////////////////////// PROPOSED MULTI-TENANT BUILDING 1-STORY, 11,000 GSF DUMPSTER ENCLOSURE DO NOTENTERDO NOTENTERSTOPSTOPPROPO S E D BUILDI N G 1-STOR Y , 2 , 0 0 0 G S FDUMPSTERENCLOSURE MICHIGAN ROAD (US 421)BENNE T T P A R K W A Y (VAR. R / W )REDD ROAD (60 ' R /W )REDD ROAD(50' R/W)BOONE COUNTYHAMILTON COUNTYG 9,522 GSF 81' E 15' D. & U.E.602 601 105 622 621 611 672 615 614 613 612 6''SSL 6''SSL 6' 'SSL 2''W GAS METER G G G GAS METERG G GAS METERG G GAS METERG G GAS METERG G G GAS METERG G GGAS METERG G PIV6''W2' 'W2' 'W2' 'W2' 'W2' 'W 1''W 1''W 4''W UGEUGEUGEUGEUGEU G E UGE UGE UGE UGE UGE U G E UGEUG E 631 N 00°30'47" W 654.27'55.02' N 00°37'13" W N 73°44' 4 5 " E 1 3 1 . 2 3'S 16°15'44" E 744.76 ' N 25°44'45" E 23.39' CAPPED REBAR SET CAPPED REBAR SET 15' D.S. & U.E.5' N.A.E.S.& P.H.E.L2 L1L3L5L4 L6 SIGN EASEMENT L1 S 16°15'44" E 38.46' L2 S 73°44'45" W 16.53' L3 S 16°15'15" E 15.00' L4 S 73°44'45" W 20.00' L5 N 16°15'15" W 15.00' L6 N 73°44'45" E 20.00' E2 E3 E4 E5 E4 E5 G2 G2 G2 G2 G2 G2 G2 G1 G1 G1 G1 G1 G1 G1 SS1 SS1 SS1 SS1 SS1 SS1 15.3'15.3'84.5'95.4'46.9' 110.5'15.3'15.3'SS2 INV.899.4 SS2 INV.899.6 SS2 INV.900.0 SS2 INV.899.7 SS2 INV.898.5 SS2 INV.897.5 SS4 INV.897.0 SS2 INV.898.1 SS2 INV.898.3 SS2 INV.898.0 SS2 INV.897.8 SS5 INV.896.6± FFE:903.25 FFE:90 3 . 2 5 SS3 SS3 W1 W3 W3 W2 W2 W3 W3 W10 W10 W10 W10 W5 W6 W7 W8 W9 UX UX UX 204 LF OF 1 2 " R C P @ 0 . 3 4 % 21 LF OF 12" RCP @ 0.34% 45 LF OF 12" RCP @ 0.36% 63 LF OF 12" RCP @ 0.48% 12 LF OF 15" RCP @ 2.01%108 LF OF 15" RCP @ 0.40%8 7 L F O F 1 5 " RCP @ 0 . 3 5% 48 LF OF 15" RCP @ 0.40%143 L F O F 1 5" R C P @ 0.4 0 % 27 LF OF 12" RCP @ 0.33% CORE DRILL AND CONNECT NEW STORM PIPE TO EX. STRUCTURE PER CITY OF CARMEL STORMWATER STANDARDS. CORE DRILL AND CONNECT NEW STORM PIPE TO EX. STRUCTURE PER CITY OF CARMEL STORMWATER STANDARDS. STORM STRUCTURE DATA TABLE STRUCTURE I.D. 105 601 602 611 612 613 614 615 621 622 631 672 RIM ELEVATION 899.50 900.09 900.80 900.34 901.09 901.34 901.00 901.28 899.35 899.45 899.35 897.69 NEENAH CASTING DESIGNATION ex. beehive R-3286-8V R-3286-8V R-3010 R-3010 R-3010 R-3286-8V R-3286-8V R-3286-8V R-3286-8V R-4342 ex. beehive INFLOW INV, SIZE, (DIRECTION), [UP STR.] INV:896.00 12" RCP (N)[601] INV:896.17 12" RCP (E)[602] INV:895.60 12" RCP (S)[621] INV:895.95 15" RCP (NE)[612] INV:896.81 12" RCP (E)[631] INV:896.81 15" RCP (SE)[613] INV:897.10 15" RCP (SE)[614] INV:897.50 15" RCP (S)[615] INV:896.00 12" RCP (SE)[622] INV:895.00 15" RCP (E)[611] OUTFLOW INV, SIZE, (DIRECTION), [DOWN STR.] INV:896.07 12" RCP (S)[105] INV:896.87 12" RCP (W)[601] INV:895.25 15" RCP (W)[672] INV:896.52 15" RCP (SW)[611] INV:897.00 15" RCP (NW)[612] INV:897.40 15" RCP (NW)[613] INV:897.93 15" RCP (N)[614] INV:895.90 12" RCP (N)[611] INV:896.16 12" RCP (NW)[621] INV:896.90 12" RCP (W)[612] DESCRIPTION & NOTES ex. beehive inlet 2'x2' BOX 2'x2' BOX 48" DIA. MH 48" DIA. MH 48" DIA. MH 2'x2' BOX 2'x2' BOX 2'x2' BOX 2'x2' BOX 2'x2' BOX ex. beehive inlet STORM SEWER PIPE DATA TABLE UPSTREAM STRUCTURE I.D. 631 622 621 615 614 613 612 611 602 601 DOWNSTREAM STRUCTURE I.D. 612 621 611 614 613 612 611 672 601 105 LENGTH OF PIPE 27 LF 45 LF 63 LF 108 LF 87 LF 48 LF 143 LF 12 LF 204 LF 21 LF PIPE SIZE / TYPE 12" RCP 12" RCP 12" RCP 15" RCP 15" RCP 15" RCP 15" RCP 15" RCP 12" RCP 12" RCP SLOPE % 0.33% 0.36% 0.48% 0.40% 0.35% 0.40% 0.40% 2.01% 0.34% 0.34% UPSTREAM PIPE INV. 896.90 896.16 895.90 897.93 897.40 897.00 896.52 895.25 896.87 896.07 DOWNSTREAM PIPE INV. 896.81 896.00 895.60 897.50 897.10 896.81 895.95 895.00 896.17 896.00 PROJECT NO. CHECK:DRAWN: PLAN DATE: DESIGN: STATE OF No. PE10707583 OO14020 Mississinewa Drive Carmel, Indiana 46033 P: 317.324.8695 F: 317.324.8717 www.Fritz-Eng.com ashton@Fritz-Eng.com Fritz Engineering Services, LLC REVISIONS AND ISSUES BYDATE CLIENT: PROJECT: PROJECT LOCATION: PROJECT TEAM: SECTION, TOWNSHIP, RANGE: THE AVENUE AT BENNETT FARM JDF DEVELOPMENT 11710 PEBBLEPOINTE PASS CARMEL, INDIANA 46033 11/18/2020 200905 BENNETT PKWY & MICHIGAN RD. CARMEL, INDIANA 46077 HAMILTON COUNTY SW 1 4, S6, T17N, R3E SHEET NAME SHEET NO.APPROVAL PE N DI N G NOT F O R CONST R U CTI O N C401 SITE UTILITY PLAN AF AF KG 00 30'60' SCALE: 1" = 30' N "IT'S THE LAW" R Know what's below. Call before you dig. 2 WORKING DAYS BEFORE YOU DIG. KEY NOTES: E1 ELECTRIC - CONTRACTOR SHALL COORD. EXACT LOCATION, SIZE OF SERVICE WITH MEP PLANS AND POWER CO. E2 ELECTRIC - EX. TRANSFORMER. CONTRACTOR SHALL COORDINATE SERVICE WITH POWER CO. APPROX. LOCATION SHOWN. E3 ELECTRIC - PR. TRANSFORMER. CONSTRACT SHALL COORDINATE SERVICE WITH POWER CO. APPROX. SIZE/LOCATION SHOWN. E4 ELECTRIC - PR. SECONDARY ELECTRIC SERVICE. COORDINATE CONDUIT AND WIRE WITH MEP PLANS. E5 ELECTRIC - CT CABINET. REF. MEP PLANS FOR EXACT LOCATION AND TENANT DISTRIBUTION/METER LOCAITONS. G1 GAS - PROPOSED GAS SERVICE LINE. REF. MEP PLANS FOR SIZE. COORDINATE SERVICE WITH GAS CO. G2 GAS - TENANT GAS METER. REF. MEP PLANS FOR EXACT SIZE AND LOCATION. SS1 SANITARY - 6" PVC SDR 26 LATERAL @ 1.04% MIN., SEE PLAN FOR LENGTH SS2 SANITARY - CLEANOUT, TYPE 1, SEE PLAN FOR INVERTS SS3 SANITARY - 1,000 GALLON GREASE INTERCEPTOR. REF. TRICO DETAILS. SS4 SANITARY - CONNECT PR. SANITARY LATERAL TO EX. MANHOLE PER TRICO STANDARDS. SS5 SANITARY - CONNECT LATERAL TO EX. SANITARY MAIN PER TRICO REGIONAL SEWER STANDARDS. VERIFY MAIN LOCATION AND DEPTH IN FIELD BEFORE CONSTRUCTION. ST1 STORM - PR. STRUCTURE, REF. STORM STRUCTURE TABLE ST2 STORM - 6" PERF. UNDERDRAIN ST3 STORM - 8" HDPE N12 OUTLET PIPE. DISCHARGE TO DOWNSTREAM ROADSIDE DITCH AS SHOWN. PROVIDE ANIMAL GUARD ON PIPE END. ST4 STORM - BUILDING DOWNSPOUT DISCHARGE TO GRADE. REF. ARCH. PLANS FOR EXACT LOCATIONS AND SIZES/MAT'L. W1 WATER - PR. 2" CORPORATION STOP TAP ON EX. 12" DUCTILE IRON MAIN PER CITIZENS WATER STANDARDS W2 WATER - PR. 2" DOMESTIC WATER SERVICE LINE. W3 WATER - PR. 2" DOMESTIC SERVICE VALVE, (2) 1" METERS. COORDINATE SIZE/LOCATION WITH MEP PLANS. REF. DETAIL ON THIS SHEET. W4 WATER - PR. 2" PRIVATE DOMESTIC DISTRIBUTION LINE. W5 WATER - PR. 6" TAPPING SLEEVE, VALVE AND BOX ON EXISTING WATER MAIN. W6 WATER - PR. 6" PRIVATE FIRE SERVICE LINE W7 WATER - POST INDICATOR VALVE, COORDINATE TYPE AND LOCATION WITH CITIZENS & CARMEL FIRE DEPARTMENT. W8 WATER - REMOTE FIRE DEPARTMENT CONNECTION. COORDINATE EXACT LOCATION WITH CARMEL FIRE DEPARTMENT. COORDINATE SIZE OF LINE WITH MEP. W9 WATER - CONTRACTOR SHALL FIELD VERIFY LOCATION OF EXISTING WATER MAIN PRIOR TO CONSTRUCTION. W10 WATER - 1" DOMESTIC SERVICE LINE WITH 3 4" METER. COORDINATE SIZE/LOCATION WITH MEP PLANS. REF. DETAILS ON THIS SHEET UX UTILITY CROSSING, APPROX. LOCATION SHOWN. CONTRACTOR SHALL FIELD VERIFY EXACT LOCATION OF ALL EX. UTILITIES WITHIN AREA OF WORK PRIOR TO CONSTRUCTION. ENGINEER SHALL BE NOTIFIED OF ANY POTENTIAL CONFLICTS FOUND. NOTES: 1.UTILITY CROSSINGS UNDER EX. PAVEMENT SHALL BE BORED OR JACK & BORED WHERE POSSIBLE. OPEN CUTS SHALL BE AVOIDED. 2. 6XX XX# DAMAGE TO THE EXISTING RIGHT-OF-WAY SHALL BE RESTORED/REPAIRED TO THE SATISFACTION OF THE CITY AT THE COMPLETION OF THE PROJECT. THE CONTRACTOR IS ENCOURAGED TO INSPECT THE RIGHT-OF-WAY WITH THE CITY PRIOR TO THE START OF CONSTRUCTION TO DOCUMENT THE EXISTING CONDITION OF THE RIGHT-OF-WAY. EXISTING RIGHT-OF-WAY NOTE ALL STORM WATER INLETS & CATCH BASIN CASTINGS SHALL BE LABELED WITH ENVIRONMENTAL MESSAGING "NO DUMPING, DRAINS TO STREAM" CAST IN RAISED OR RECESSED LETTERS AT A MIN. 1-INCH HEIGHT. A SYMBOL OF A FISH SHALL ALSO BE CAST WITH THE LETTERS STORM SEWER INLET NOTE ALL STORM SEWER INFRASTRUCTURE TO BE CONSTRUCTED WITH THE PROJECT LIMITS SHALL BE PRIVATELY OWNED AND MAINTAINED BY OWNER. STORM SEWER SYSTEM NOTE CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS, INCLUDING UTILITIES AND DRAINAGE INFRASTRUCTURE BEFORE COMMENCING WITH CONSTRUCTION. CONTRACTOR TO NOTIFY ENGINEER OF ANY DISCREPANCIES. EXISTING CONDITIONS NOTE 2" WATER SERVICE CONNECTION DETAIL 1" WATER SERVICE CONNECTION DETAIL F:\2020\2009005 - JDF Development Carmel\02 Civil\Plans\C401.dwg, C401, 11/18/2020 2:12:45 PM, Ashton Fritz, DWG To PDF.pc3, ANSI full bleed D (34.00 x 22.00 Inches), 1:1