HomeMy WebLinkAboutS 201 0Roof Trusses Designed by:
ROOF TRUSS LAYOUT
Scale:1/4" = 1'-0"
CAD file:
Page:
Content:
-
Checked by:
Job Number:
Customer:
-
2106257-12T
SBKBrief Description Of RevisionWRITTEN CONSENT OFRESERVEDSPECIFICATIONS AS NECESSARY WITHOUTREPRESENT PROPRIATARY MATERIAL &ARE NOT TO BE COPIED, REPRODUCEDOR UTILIZED WITHOUT THE EXPRESSDUE TO AVAILABILITY AND CONTINUOUSPRODUCT IMPROVEMENT.STARK TRUSS, INC. RESERVES THE RIGHTTO CHANGE PRODUCT TYPES AND\ORStark Truss Co. Inc.THESE DRAWINGS, PLANS & CONTENTS2021 ALL RIGHTSC Date Rev. No.NOTICE.Rev. By: Contract Lumber1317 North Owen Street Rensselaer, Indiana 47978FAX (219) 866-2795 PHONE (219) 866-2772SBK1-25-21 Layout For ConstructionORIG.123Notes:
1. Dimensions: Feet - Inch - Sixteenth
2. Dimensions are outside face of bearing to face of truss, unless otherwise noted.
3. Truss to truss dimensions are face to face.
4. All walls/beams shown are considered load bearing, unless otherwise noted.
5. Wall Hts. and Widths are per print.
6. All bearing/uplift clips are mark "A" unless otherwise noted.
7. See individual truss drawings for permanent bracing requirements.
8. Do Not Scale - Call For Missing Dimensions.
T01GE
T01
T01
T01
T03
T05
T05
T06
T07
T10
T11 T14GET14T15T16T17T18T19T20T21T22T23T13
J0
2T24GET25T26T27T28T29T30T31T09J03J04J04J05 J06J05
J10
J11J09J08J08
T12
T12GE
V01
V02
V07V08V09V10V06V11V12V13V14V15V16V17V18V19V20V21V22V23V05
V04
V03
P01
P03
P02
P01 T04(3)T08(10) P02 (13)J01(6)J12(11)J07(3)
T02-T07
Offset/Share
Bearing With
J10-J12
T06, T08, T10-T12GE
Cantilever 2-04-00
Past Garage Wall 4-01-005-06-00 5-01-00 5-06-00 2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
11-00
1-01-00
1-00-00
1-00-00
2-00-00
1-10-0827-00-0019-06-00 7-02-00 54-00-001-07-00
22-11-0019-00-00 10-06-00 54-00-006-08-00 58-04-00 6-01-00
2-01-0073-06-00
51-00-00 20-06-00
2-00-00 73-06-00
4-00 4-0012-04-002-04-00
9-10-00 1-02-002-02-0011-06-00
2-02-008-04-00
4-08-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-0028-02-001-10-082-00-002-00-002-00-001-10-08
2-00-00
2-00-00
9-00
2-00-002-00-002-00-00
10-061-06-082-00-002-00-001-00-001-081-06-08
2-00-00
2-00-00
2-00-00
7-08-002-00-007-08-00
6-00-002-00-00
2-04-0020-00-00
C
D
B
B
B
B
B
B
B
B
B
B
D
B B B B B B B
BB B B
B
BB B BB
P02P02 (10) T32 No Cap Truss
For T09
No Cap Truss
For T07
Take Care To Set
T02A Over Range
For Range Vent Clearance
T02
T02
T02A
02/10/21