Loading...
HomeMy WebLinkAboutA000.7\A1;1'-0"\PTYP. \A1;4'-0" POT VENTS \A1;3'-0" \A1;3'-0" GUTTER AND DOWNSPOUTS "A" 2572 ROOF AREA: SQ. FT. 9:12 8:12 9:12 9:12 8:12 8:12 8:12 8:12 9:12 9:12 9:12 9:12 9:12 "C" 198 ROOF AREA: SQ. FT.ROOF AREA "B"SQ FTG102AT / NEAR RIDGEAT / NEAR EAVEVENT TYPESQ. FT.REQUIREDRANGESQ. FT.SUPPLIEDPERCENTOF TOTALSUPPLIEDPOT LARGE(SQ. IN. EACH)POT SMALL(SQ. IN. EACH)RIDGE VENT(SQ. IN. PER LF)EAVE VENT(SQ. IN. EACH)CONT. VENT(SQ. IN. PER LF)61.0040.0018.0028.0010.00HIGH - POTVENTS ONLY0.140.170.4246.5610AT EAVE0.200.170.4953.4407.00TOTAL (MIN)0.340.340.91100.003 HIGH -RIDGE VENT0.140.170.00####000.00AT EAVE0.200.170.00######00.00TOTAL (MIN)0.340.340.00######ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLEROOF AREA "C"SQ FTG198AT / NEAR RIDGEAT / NEAR EAVEVENT TYPESQ. FT.REQUIREDRANGESQ. FT.SUPPLIEDPERCENTOF TOTALSUPPLIEDPOT LARGE(SQ. IN. EACH)POT SMALL(SQ. IN. EACH)RIDGE VENT(SQ. IN. PER LF)EAVE VENT(SQ. IN. EACH)CONT. VENT(SQ. IN. PER LF)61.0040.0018.0028.0010.00HIGH - POTVENTS ONLY0.260.330.4243.2610AT EAVE0.400.330.5656.7408.00TOTAL (MIN)0.660.660.98100.003 HIGH -RIDGE VENT0.260.330.5047.37004.00AT EAVE0.400.330.5652.6308.00TOTAL (MIN)0.660.661.06100.00ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLEELEVATION HR2MATTIC VENT SCHEDULEVENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS* SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATIONROOF AREA "A"SQ FTG2572AT / NEAR RIDGEAT / NEAR EAVEVENT TYPESQ. FT.REQUIREDRANGESQ. FT.SUPPLIEDPERCENTOF TOTALSUPPLIEDPOT LARGE(SQ. IN. EACH)POT SMALL(SQ. IN. EACH)RIDGE VENT(SQ. IN. PER LF)EAVE VENT(SQ. IN. EACH)CONT. VENT(SQ. IN. PER LF)61.0040.0018.0028.0010.00HIGH - POTVENTS ONLY3.434.294.2449.59100AT EAVE5.144.294.3150.41062.00TOTAL (MIN)8.578.578.54100.003 HIGH -RIDGE VENT3.434.294.1448.22806.00AT EAVE5.144.294.4451.78064.00TOTAL (MIN)8.578.578.58100.00ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE"B"102ROOF AREA:SQ. FT.4:12A4.01 ROOF PLANMidwest Zone Office1900 Golf Road - Suite 300Schaumburg, Illinois 60173(c) Copyright 2015 PulteGroup, Inc. PRODUCT MANAGER----VERSION RELEASEDATE:xx/xx/xxxxPROJECT TYPE Single Family SHEET PLAN NAME SPECIFICATION LEVEL NPC CHILD NUMBER ---- Rockwall 2054.300Home for * Market Home *, 7231-036002834 Towne Meadow Drive, Carmel, IN 46032ROOF PLANSCALE: 1/4" = 1'-0" (HALF SCALE ON 11x17 PAPER) 02/17/21