Loading...
HomeMy WebLinkAboutE700Switch leg or Go-between All conductors #12 AWG Circuit No. designation All conduit 3/4" unless may be in 1/2" size, others as noted. 1. #12 AWG is min. conductor size except as noted. 2. 3/4" conduit is min. Size except as capacity permitting 24 volt control conductors and switchlegs 3. 1/2" is min. Flexsteel, Greenfield and Sealite size. Notes: AL1-1,3,5 otherwise noted otherwise noted Ground conductor(s) (if used) Panel designation Phase conductor(s) Neutral conductor(s) 'NGEVTKECN5[ODQNU.GIGPF Lighting Switches Power Circuiting Conduit system concealed above ceiling Conduit system under floor Homerun. Conduit system to panel as noted on drawings Junction box Conduit up Conduit down Surface mounted conduit system Single pole switch Disconnect switch Duplex receptacle (20Amp rated) Ground fault interrupt receptacle (20Amp rated) Motor connection Wall mounted fixture Surface mount round LED fixture NOT TO SCALE 2 E700 KEY TO ELECTRICAL CIRCUIT WIRING 4' linear fixture } Note: E.C. shall follow this detail for proper grounding connections. 3/0 CU shunt around water meter (Typ. for 3 or 4 rod grounding field) 3/0 CU 10' Min. Disc. Link Equipment ground bus Neutral bus At Main Distribution Panel (MDP) To concrete encased electrode (in min. of 2" concrete within or near bottom of foundation/footing with min. of 20'-0" of bare copper conductor not smaller than #4 AWG.) Connection to cold water system 3/0 CUConnection to structural steel of building 3/0 CU 3/0 CU 3/0 CU3/0 CU (3) 3/4" copperweld 10' long ground rods 3/0 CU to water meter Water meter Cold water pipe Surge arrestor 3/0 CUTo dry transformer(s) Fusable switch WP Weatherproof, ground fault interrupt receptacle (20 Amp rated) with "While-In-Use" cover NOT TO SCALE 1 E700 GROUNDING DETAIL Notes 1.Switches shall be a maximum +48" A.F.F. to the top of the device unless otherwise noted on plans. 2.Receptacles, telephone outlets, and television outlets shall be a minimum of +18" A.F.F. to the bottom of the device unless otherwise noted on plans. 3.Not all symbols listed above are shown on plans. The symbol legend is used for reference of symbols shown on plans. See specifications for information related to symbols. Wall switch type dual technology occupancy sensor with minimum fan run-time (controls lighting load and exhaust fan). Refer to Manufacturer's instructions for exact installation requirements prior to rough-in. Wall switch type dual technology occupancy sensor. Refer to Manufacturer's instructions for exact installation requirements prior to rough-in. Switch leg or Go-between All conductors #12 AWG Circuit No. designation All conduit 3/4" unless may be in 1/2" size, others as noted. 1. #12 AWG is min. conductor size except as noted. 2. 3/4" conduit is min. Size except as capacity permitting 24 volt control conductors and switchlegs 3. 1/2" is min. Flexsteel, Greenfield and Sealite size. Notes: AL1-1,3,5 otherwise noted otherwise noted Ground conductor(s) (if used) Panel designation Phase conductor(s) Neutral conductor(s) 'NGEVTKECN5[ODQNU.GIGPF Lighting Switches Power Circuiting Conduit system concealed above ceiling Conduit system under floor Homerun. Conduit system to panel as noted on drawings Junction box Conduit up Conduit down Surface mounted conduit system Single pole switch Disconnect switch Duplex receptacle (20Amp rated) Ground fault interrupt receptacle (20Amp rated) Motor connection Wall mounted fixture Surface mount round LED fixture NOT TO SCALE 2 E700 KEY TO ELECTRICAL CIRCUIT WIRING 4' linear fixture } Note: E.C. shall follow this detail for proper grounding connections. 3/0 CU shunt around water meter (Typ. for 3 or 4 rod grounding field) 3/0 CU 10' Min. Disc. Link Equipment ground bus Neutral bus At Main Distribution Panel (MDP) To concrete encased electrode (in min. of 2" concrete within or near bottom of foundation/footing with min. of 20'-0" of bare copper conductor not smaller than #4 AWG.) Connection to cold water system 3/0 CUConnection to structural steel of building 3/0 CU 3/0 CU 3/0 CU3/0 CU (3) 3/4" copperweld 10' long ground rods 3/0 CU to water meter Water meter Cold water pipe Surge arrestor 3/0 CUTo dry transformer(s) Fusable switch WP Weatherproof, ground fault interrupt receptacle (20 Amp rated) with "While-In-Use" cover NOT TO SCALE 1 E700 GROUNDING DETAIL Notes 1.Switches shall be a maximum +48" A.F.F. to the top of the device unless otherwise noted on plans. 2.Receptacles, telephone outlets, and television outlets shall be a minimum of +18" A.F.F. to the bottom of the device unless otherwise noted on plans. 3.Not all symbols listed above are shown on plans. The symbol legend is used for reference of symbols shown on plans. See specifications for information related to symbols. Wall switch type dual technology occupancy sensor with minimum fan run-time (controls lighting load and exhaust fan). Refer to Manufacturer's instructions for exact installation requirements prior to rough-in. Wall switch type dual technology occupancy sensor. Refer to Manufacturer's instructions for exact installation requirements prior to rough-in. 10 9abcd 8 7 6efgh109876 REVISIONS AND ISSUES5 4 3 2 1 PREPARED FOR:PROJECT NO. SHEET NO.abcd5 4 3 2 CHECKED BY:DRAWN BY:DESIGNED BY:DWG NAME:PROJECT NO.:DATEBYeDATE:1 ENGINEERS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546 faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netfhgSection 1, Township 17 North, Range 3 East, Clay Township, Hamilton County, IndianaW200371CARMEL, IN 46033W20062003/05/2021LAWRENCE W. INLOW PARKPHASE II IMPROVEMENTSPROF E SSIONA L E N G NIEERSA M U E L L.HU R TINDIA N A 0 N EP1 6 .o 01087 ATS FOET R E TEGIS D ER Exp. 7.31.2022 Genesis Design, Inc.GNIBMULP·LACITCELE·LACINAHCEM R2410 Executive Drive - Suite 100 Indianapolis, Indiana 46241 317.636.3941 YYY6'%Ä/'2EQO THEENGINEERINGC O L L A B OR A T I VEKnow what's below. before you dig.Call R SJWSLHSJW