HomeMy WebLinkAboutM600'ZJCWUV(CP5EJGFWNG Mark Area Served Model Airflow (CFM) Static Pressure (in. w.g.) Electrical Connection Weight (lbs)Remarks Voltage (V) Phase (Ø) Power (HP)Disconnect EF-1 Equipment Room Greenheck SQ-95-G 300 0.4 120 1 0.05 MFR 41 1,2,3 EF-2 Various SQ-80-D 200 0.4 120 1 0.05 MFR 41 1,2,4,5 EF-3 Various Greenheck SQ-95-G 375 0.4 120 1 0.05 MFR 41 2,4 Notes: 1.Inlet Guard screen by MFR. 2.Direct drive with solid state speed controller. 3.Fan shall run from T-stat in space. See Sequence of operations for more information. 4.Fan shall operate from disconnect. 5.Fan and all components need to be Hi-Pro Polyester coated for corrosion resistance. 'NGEVTKE9CNN*GCVGT5EJGFWNG Mark Area Served Raywall Model Type Electrical Connection Disconnect Remarks Power (Watts)Voltage (V)MCA (A) EWH-1 Family Rest Room (003) Raywall AFA Series Wall Heater 1500 240 6.2 MFR 1,2,3 EWH-2 Various Raywall AFC/AFH Wall Heater 2000 240 8.3 MFR 1,3,4 Notes: 1.Fan forced heater. 2.Integral Tamper proof T-Stat to prevent adjustment by unauthorized personnel. 3.Recessed. 4.Provide Tamper proof T-stat. Thermostat control knob shall be covered by a 16 gauge tamper-proof access plate to prevent adjustment by unauthorized personnel. 6GTOKPCN1WVNGVU Mark Function Price Model Airflow Range (CFM) Face Size (in.) Neck Size (in.)Color Remarks ER-1 Exhaust Register 530 0-100 7 3 4 x 7 3 4 6 x 6 By Architect 1,2,3 Notes: 1.Provide factory extended panel for any diffuser which is smaller than the grid in which it is installed. 2.Sound baffle by Sheet Metal Contractor. 3.Provide plaster frame for diffusers, registers and grilles installed in gypsum board. Exhaust Fans: EF-1: Exhaust fan shall run from Temperature sensor (see M100 for location). EF shall operate when Temp goes above 85°F[adj] and shall operate until temperature in space is 75°F[adj]. EF-2: Exhaust fan shall run continuously. EF-3: Exhaust Fan shall run continuously when the restrooms are open for public use. 5GSWGPEGQH1RGTCVKQPU .QWXGTU Mark Function Greenheck Model Air Volume (CFM) Static Pressure (in w.c.) Size Type Remarks LVR-1 Exhaust EDJ-401 200 0.08 12 x 12 Wall 1,2,3,4 LVR-2 Exhaust EDJ-401 1400 0.08 30 x 24 Wall 1,2,3,4 LVR-3 Intake EDJ-401 1100 0.08 24 x 24 Wall 1,2,3,5 Notes: 1.Color selected by architect. Provide Insect screen. 2.Maintain at least 10'-0" between intakes and exhausts and all other flues or vents. 3.All Sheet-metal transitions shall be provided by the contractor. 4.Louvers must be Kynar coated for corrosion resistance. 5.Back Draft Damper. Field verify size prior to ordering. See Plans for more information. 10 9abcd 8 7 6efgh109876 REVISIONS AND ISSUES5 4 3 2 1 PREPARED FOR:PROJECT NO. SHEET NO.abcd5 4 3 2 CHECKED BY:DRAWN BY:DESIGNED BY:DWG NAME:PROJECT NO.:DATEBYeDATE:1 ENGINEERS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546 faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netfhgSection 1, Township 17 North, Range 3 East, Clay Township, Hamilton County, IndianaW200371CARMEL, IN 46033W20062003/05/2021LAWRENCE W. INLOW PARKPHASE II IMPROVEMENTSPROF E SSIONA L E N G NIEERSA M U E L L.HU R TINDIA N A 0 N EP1 6 .o 01087 ATS FOET R E TEGIS D ER Exp. 7.31.2022 Genesis Design, Inc.GNIBMULP·LACITCELE·LACINAHCEM R2410 Executive Drive - Suite 100 Indianapolis, Indiana 46241 317.636.3941 YYY6'%Ä/'2EQO THEENGINEERINGC O L L A B OR A T I VEKnow what's below. before you dig.Call R AKSLHAK